Philips HC85P User Manual

HC Series
Explosion-Proof Emergency Power Unit
Page 1 of 2
12. 0"
(30.5 cm)
HC28N
15.0 "
(38.1 cm)
13.0"
(33.0 cm)
8.8"
(22.4 cm)
(8.9 cm)
3.5"
10.0"
(25.4 cm)
6.0"
(15.2 cm)
Features
is accomplished with
incandescent or compact
fluorescent F Series fixtures.
The F Series fixtures must be
ordered separately.
Housing: Copper-free cast
aluminum enclosure designed
to withstand the pressure
of explosions generated
by internal arc without
propagating them into the
hazardous atmosphere.
Suitable for use in Class I, Div.
1, Groups C & D, Zones 0, 1 &
2, Groups IIA, IIB + H
Class I, Div. 2, Groups C & D,
Zone 2, Groups IIA, IIB + H2 &
IIC; Class II, Div. 1, Groups E,
F & G; Class II, Div. 2, Groups
F & G; and Class III hazardous
location areas. Enclosure
and cover are constructed
separately. Cover is threaded
to allow easy attachment and
removal. Enclosure includes
three threaded openings for
3/4” rigid conduit — one for
AC input and two for mounting
hazardous fixtures.
Operating Temperature
Range: Pure Lead Units
65°F (19°C) to 85°F (30°C)
Nickel Cadmium Units
20°F (-7°C) to 95°F (35°C)
& IIC;
2
Electronics: 120/277 VAC
dual voltage input with
surge-protected, solid-state
circuitry provides for a reliable
charging system. HC85P uses
a temperature compensating
charger. Charging system is
complete with low voltage
disconnect, AC lockout,
brownout protection, AC
indicator lamp and test switch.
HC14N power pack operates
7 watt compact fluorescent
hazardous fixtures in both
AC and emergency modes.
HC28N, HC50N and HC85P
power units operate 6 and 12
volt incandescent hazardous
fixtures in emergency mode
only.
Electrical Specifications:
HC28N: (120 VAC) 0.15 A, 60
Hz, (120 VAC) 0.08 A, 60 Hz
HC50N, HC85P: (120 VAC)
0.33 A, 60 Hz, (120 VAC) 0.16
A, 60 Hz
HC14N: (120 VAC) 0.50 A, 60
Hz, (120 VAC) 0.25 A, 60 Hz
Job Information Type:
Job Name:
Cat. No.:
Notes:
Code Compliance
UL 924, 844, 1203 and 1604
listed. NFPA 101, NEC, BOCA,
OSHA and IBC illumination
standards.
Warranty
Three year full electronics
warranty. Five year full plus five
year prorated nickel cadmium
battery warranty. One year full
plus four year prorated pure
lead battery warranty.
Explosion-Proof Emergency Power Unit
Ordering Information
HC
Series
HC = Hazardous Location Emergency Lighting Power Pack
Note
1) Compatible only with F Series f ixtures using 7 W compact fluorescent lamps. Will not oper ate incandescent lamps. Maximum remote mounting distance from the HC14N is 8 feet.
2) 15 minute delay.
Accessories (order as a separate item) OB3 = 3-Way Explosion Proof 3/4" Conduit Hub SEA = Swivel Elbow Arm for Use With Pendant Mount Fixture to Connect to OB3 or HC U nit EVLA12 = 12 V, 12 W Directional Head
Voltage/Batter y
6 Volt, Nickel Cadmium
14N = 14 W Power Pack, Compact Fluorescent L amp Operation, AC and E mergency Operation 28N = 28 W Power Pack, Incandescent Lamp Operation, Emergency Operation Only
6 Volt, Pure Lead 85P = 85 W Power Pack, Incandescent Lamp Oper ation , Emergency Operation Only
12 Volt, Nickel Cadmium 50N = 50 W Power Pack, Incandescent Lamp Operation, Emergency Operation Only
9.0"
(22.86 cm)
4.6"
(11.68 c m)
HC Series
Page 2 of 2
Factory Installed Options
EX = Special Input Transformer
1
(specify voltage & frequency)
T1 = 120 VAC Time Delay T2 = 277 VAC Time Delay
2
2
9.0"
(22.86 cm)
Sample Application
The sample application above consists of: (1) HC14N - 14 W power pack for exclusive use with compact fluorescent fixtures (2) SEA - elbow arms (1) FPHFP7 - 7 W compact fluorescent lamp fixture (operates in AC and emergency mode) (1) FPHFP7EFK - 7 W compact f luorescent lamp fixture with exit accessory (operates in AC and emergency mode)
Philips Lightolier e: lol.webmaster@philips.com t: (508) 679-8131 w: www.lightolier.com
HC Series May 4, 2012
Specifications are subject to change without notice. © Koninklijke Philips Electronics N.V., 2012. All rights reserved.