Philips EG1-4 User Manual

Page 1
Lighting Systems
EG1-4

Page 1 of 5

1
5

Feature Specifications Electrical

Connections: Wiring is via 18 gauge wire. All electrical connections for standard

Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver

2 3

Features

1. Housing: 18 gauge steel. 6" (15.24cm) cast aluminum end caps. No exposed
fasteners or hardware.
2. Lamping: 1 T5 fluorescent lamps per 4' (121.92cm) section. Lamps by Lightolier
as an option, see ordering information.
3. Reflector: Precision die-formed premium anti-iridescent, highly reflective alu
minum.
4. Louver: Parabolic louver, low-iridescent semi-specular anodized aluminum, 25
degree shielding lengthwise. Blades are spaced 2.3" (5.84cm) O.C with a radius that matches the housing. 1" (2.54cm) tall louver attaches to housing.
5. Optional Slotted Top Reflector: Precision die-formed anti-iridescent, highly
reflective aluminum.
All sfafic ballasfs have fhe following feafures:
• Elecfronic
• High Power Facfor
• Class A sound rafing
• Mefal can
Emergency Battery Pack: Emergency Battery packs are designed to operate
when normal building power is interrupted. The battery packs operate for a mini mum of 90 minutes without any power via a rechargeable battery source. The pack does not utilize the standard static ballast for any of its operation since the pack carries its own pseudo ballast. For this reason, Lightolier does not recommend remote mounting EM Packs because all of the socket wiring would need to carry throughout the power feed end set. The EM batteries, even in their largest, most expensive form, operate the fluorescent lamps at only half the lamp rated output. Emergency battery packs are available in the following outputs:
• 450 Lumens (Standard)
• 635 Lumens
• 1100 Lumens
• 1375 Lumens
Emergency battery packs can be used for emergency egress lighting since all listed packs operate for a minimum of 90 minutes, or can be used as momentary lighting for emergency circuit power transitions. Smaller packs are recommended for this purpose.
Dimming: T8 and T5H0 lamps are dimmed with two wire ballasts. T8 lamps can
be dimmed down to 5% and T5H0 lamps can be dimmed down to 1%. T5 lamps require 5-wire dimming ballasts and can be dimmed down to 1%. A 5-wire power feed will be required for T5 (non-HO) dimming.

Labels Included

UL, cUL,and IBEW

Mountings

Cable suspension is on 48" (121.92cm) and 96" (243.84cm) centers and consists of a 4 1/2" (11.43cm) diameter canopy finished white enamel. A 1/16" (0.16cm) diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 12" (30.48cm) to 36" (91.44cm). Power feed is 18-gauge SJT white cord. For special circuiting consult factory.

Finish

Powder coated, baked enamel, white or aluminum, as specified. Custom colors available, consult factory.

Ordering Instructions

Individual Fixtures:
1. Order number of MODULES required.
2. Order one POWER FEED END SET per MODULE.
Continuous Rows:
1. Determine run length.
2. Order the appropriate number of MODULES for the complete run.
3. Order one POWER FEED END SET for each run.
4. Order one CABLE ASSEMBLY per MODULE minus one per run.
5. For runs that exceed conductor ampacity ratings order the appropriate number of SINGLE CABLE & CORD SETS.
Job Information
Job Name:
Cat. No.:
Lamp(s): Notes:
1 Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • F1109
PHILIPS
LIGHTOLIIzir
Page 2
Lighting Systems
EG1-4

Page 2 of 5

Module Ordering Information

Family

When ordering no lamps provided by Lightolier, use Lamp code "Z".

Series Lamping &
EG 1
Distribution

1 = 1 Lamp

4 = 1 Lamp,
Slotted Top Reflector
Ballast Lamp Shielding Length Voltage Finish
See Ballast Chart Below
P
See Lamp Chart Below
r P
P = Parabolic
Louver

Module Ordering Specifications Lamping and Distribution

1 = 1 Lamp 4 = 1 Lamp, Slotted Top Reflector
Ballast Specifications
Code Lamp Type Ballast Factor
F T5 1.00 Program <10
G T5H0 1.00 Program <10
I Dim T5 1.00/.01 Program <10
J Dim T5H0 1.00/.03 Program <10
Dimming: Advance Mark-10 standard (no additional wires required) for T8 and
T5H0 fixtures. 5-wire dimming required forT5 (non-HO) fixtures. Optional dimming systems: Lutron ECO-10 and Hi-Lume (by others) require 4-wire modules and end sets. Mark-7, ULT, DALI and Lightolier HDL require 5-wire power feed end sefs.
Energos can accepf ballasfs not to exceed 1.7" (4.32cm) wide by 1.2" (3.05cm)
high.
Start Type
THD %

Shielding

P = Parabolic Louver

Length Voltage Finish

4 = 4ft (48") (121.92cm) 1 = 120VAC A = Aluminum 8 = 8ft (96") (243.84cm) 2 = 277VAC W = White

Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver

Options

(Blank)
P
4 = 4'(121.92cm) 8 = 8' (243.84cm)
Code Lamp Type Wattage
M T5 28 2600* 830 N T5 28 2600* 835
0 T5 28 2600* 841
P T5 54 4450* 830 Q T5 54 4450* 835 R
25°c Rating
1 = 120V
2 = 277V
Lamping Specifications
T5 54 4450* 841
A = Aluminum W = White
Rated Output
(Lumens)
4= 4 through wires 5= 5 through wires 6= 6 through wires D= Dual Switch T= Tandem Switch E= Emergency Pack
Color (K)

Feature Options (continued)

E = Emergency Battery Pack (E): Baffery packs provide 90 minufes of opera-
fion. Available lamp oufpufs: 450 Lumens (sfandard). Opfional: 635,1100 and 1375 Lumens. Sfandard Emergency wiring is fo have Baffery Pack operafing a single
lamp. All EM fixfures are wired as "swifched" and include 4fh fhrough wire for fhe wall swifch (see diagrams). All fixfures and power feeds in fhaf run should be ordered fo include a dedicafed 4fh fhrough wire fo carry fhe hot power all the way through the run to the EM pack.

Wiring Options

Blank = Leave blank if ordering sfandard fixfure. 4 = 4 fhrough wires 5 = 5 fhrough wires 6 = 6 fhrough wires

Feature Options

D = Dual Switching (AKA A/B swifching)
]□[
2-Light Option 3-Light Option
T = Tandem Switching (also available in 1-lamp configuration)
A B
Both Dual Switch and Tandem Switch fixtures ship with a 4th wire. Be sure to order the appropriate quantity of wires in fhe power feed.
631 Airporf Road, Lall River, MA 02720 • (508) 679-8131 • Lax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lighfolier.com © 2009 Philips Group • L1109
Unswitched Switched
Job Information Type:
PHILIPS
LIGHTOLIIzir
Page 3
Lighting Systems
EG1-4

Page 3 of 5

Fixture Lengths & Mounting Locations

I-«—48^' (121.92cm)—
4-Foot Run iT Ti
16-Foot Run
20-Foot Run
24-Foot Run
5' (152.40cm) OA
[-
-----------------------
!-•— 48^' (121.92cm)
,|T T-
------------
h
-----------
-48^' (121.92cm)—
t
96^' (243.84cm) -
9' (274.32cm) OA
-----------
96^' (243.84cm)
-96" (243.84cm)-
-96“ (243.84cm)-
13' (396.24cm) OA
------------
-96^' (243.84cm)
17' (518.16cm) OA
------
21' (640.08cm) OA
----------------------
-----------
96^' (243.84cm)
96^' (243.84cm)-----------------------►
25' (762.00cm) OA
------------

Suspenslon and End Set Ordering Illustrations

Power Feeds
Consult Lamp and Ballast System data to determine Input watt requirements for ballast used on project to determine loading for each run. Mulfiply fhe fötal num ber of ballasfs by fhe Inpuf waffage per ballasf, and fo defermlne ampacify divide fhe fötal watts by the system voltage. 10 Amps for 3-wlre end sefs, 7 Amps for 4-wlre and 5-wlre end sefs, maximum.
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
4' (121.92cm)
Module
4' (121.92cm) Run
8' (243.84cm) Run 12' (365.76cm) Run 1 1 1 1 16' (487.68cm) Run 2 1 1
- 20' (609.60cm) Run 1 2 1 2
^ 24' (731.52cm) Run 3 1 2
--
-96^' (243.84cm)-
----------------------
96^' (243.84cm)-----------------------►

Control

Consulf appropriafe ECS (Energos Confrol Sysfems) specificaflon sheef for ordering producf uflllzing occupancy confrols. ECS specificaflon sheef numbers direcfly cor relare fo sfandard Energos specificaflon sheef numbers.
1
8' (243.84cm)
Module
1
End Set
1 1
Cable Joiner

Power Feed End Set

Whife, 3 Wire Cord Whife, 4Wlre Cord Whife, 5 Wire Cord Aluminum, 3 Wire Cord Aluminum, 4 Wire Cord Aluminum, 5 Wire Cord
631 Airport Road, Pall River, MA 02720 • (508) 679-8131 • Eax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • E1109
EG1EC36W EG1EC36W4 EG1EC36W5 EG1EC36A EG1EC36A4 EG1EC36A5
Ceiling Grid Kit: CGK
Single Cable & Power Cord: EGCC36 Single Cable & 4 Wire Power Cord: EGCC36X4 Single Cable & 5 Wire Power Cord: EGCC36X5
Because mosf ceilings are whife, all canopies ship as whife
unless specifically ordered otherwise.
Both CGK and CGKP ship with two types of clips (sfandard and slot T).
Eor mounting fixtures directly to the T grid, order one CGK per non-power suspension point and one CGKP per powered suspension point.
The CGKP will Include a special canopy with flex coupler, grid clips and addiflonal clips fo mounf fhe juncflon box fo the top of the grid nearby. J-Box and flex condulf provided by others.

Cable/Cord Assembly

Ceiling Grid Kit, Power: CGKP
Job Information Type:
PHILIPS
LIGHTOLIIzir

Cable Assembly

Single Cable: EGC36
Page 4
Lighting Systems
EG1-4

Page 4 of 5

Performance — One Lamp

Report No.: Lamps: Lumens: Efficiency: Caf. No.: 25°C Rafing
EG1-4N-GQ.ies 1-EP54/835/H0 4450
93.4 EG11GQP

Fixture With Open Top

Candlepower Coefficienfs Of Ufilizafion
Zone^ 0 22 45 67 90
Degree 80 70 50
4
180 520 520 520 520 520 175 522 522 524 523 523 165 502 511 528 541 548 1 86 82 80 78 75 72 62 60 59 155 465 487 520 546 558 145 409 449 504 546 566 135 339 398 473 541 574 125 255 333 436 546 611 115 167 263 449 670 716 105 82 211 562 925 995
95 14 234 264 357 374 8 38 31 27 35 29 25 29 24 21 90 0 0 0 0 0 9 35 28 23 32 26 22 26 22 18 85 0 0 0 0 0 10 32 25 21 29 23 19 24 19 16 75 2 3 3 4 4 20% Eloor Cavify Reflecfance 65 25 52 18 59 125 55 115 271 206 69 50 45 258 320 738 825 745 35 352 378 440 619 821 25 417 431 459 489 503 15 466 470 481 492 497
5 498 498 498 496 495 0 498 498 498 498 498
Candelas

Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver

% Effecfive Ceiling Cavify Reflecfance
50 30 10 50 30 10 50 30 10
0 97 97 97 88 88 88 70 70 70
_o
2 76 70 66 68 64 60 55 52 49
CD
CC 3 67 60 55 61 55 51 49 45 42
.-&■
4 59 52 47 54 48 43 44 39 36
CD
CJ
5 53 46 40 48 42 37 39 35 31
E
6 47 40 35 43 37 32 35 30 27
o
CC
7 42 35 30 39 32 28 32 27 24
Zone Lumens
0-90 1534 31 33
90-180 3134 63 67
0-180 4668 93 100
% Wall Reflecfance
Disfribufion
% Lamo
% Luminaire

Performance — One Lamp

Candlepower Curve
Lumens: Efficiency: Caf. No.: 25°C Rafing
4450
73.5 EG14GOP

Fixture With Optional Slotted Top Reflector

Candlepower
Zone^
Degree
4
180 204 204 204 204 204 175 224 211 232 218 214 165 210 211 220 220 214 155 190 203 208 216 214 145 174 180 202 206 216 135 140 157 177 171 164 125 108 130 123 83 68 115 74 90 42 8 6 105 39 29 11 26 27
95 7 5 10 10 14 90 0 3 5 4 3 85 0 5 24 38 41 75 4 8 15 36 38 65 76 175 218 268 257 55 285 460 807 981 1047 45 433 616 664 960 1123 35 538 682 848 813 811 25 602 756 850 967 1035 15 671 749 831 901 886
0 22 45
Candelas
5 680 708 703 750 737 0 687 687 687 687 687
67 90
Job Information Type:
Coefficienfs Of Ufilizafion
% Effecfive Ceiling Cavify Reflecfance
80 70 50
Wal Reflecfance
50 30 10 50 30 10 50 30 10 0 84 84 84 80 80 80 74 74 74 1 74 72 69 71 69 67 66 64 62 2 65 61 57 63 59 56 58 55 52 3 58 52 48 55 51 46 51 47 44 4 51 45 40 49 44 39 46 41 37 5 45 39 34 44 38 34 41 36 32 6 40 34 30 39 33 29 36 31 28 7 36 30 26 35 29 25 33 28 24 8 33 27 23 32 26 22 30 25 21 9 30 24 20 29 23 20 27 22 19
10 27 22 18 27 21 18 25 20 17
Zone
0-90 1739 60 82
90-180 393 14 18
0-180 2132 74 100
y
20% Eloor Cavify Reflecfance
Disfribufion
Lumens % Lamp % Luminaire
631 Airporf Road, Eall River, MA 02720 • (508) 679-8131 • Eax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lighfolier.com © 2009 Philips Group • E1109
PHILIPS
LIGHTOLIIzir
Page 5
Lighting Systems
EG1-4

Page 5 of 5

Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver

Ballast and Lamp Ordering Combinations

Desgn.

Notes:

*25°C Rating All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania Specifications When ordering no lamps provided by Lightolier, use Lamp code "Z".
The lumen value for the lamp (within a Lighting Design program) will be the lES Output value shown on this table.
Lamp Type
(T8 or T5)
FM T5 1 <10 28 2600 830 2600 31.0 83.9 20000 Program FN T5 1 <10 28 2600 835 2600 31.0 83.9 20000 Program FO T5 1 <10 28 2600 841 2600 31.0 83.9 20000 Program
GP HO 1 <10 54 4450 830 4450 58.5 76.1 20000 Program GO HO 1 <10 54 4450 835 4450 58.5 76.1 20000 Program GR HO 1 <10 54 4450 841 4450 58.5 76.1 20000 Program
IM T5DIM 1.0/.01 <10 28 2600 830 2600 /26 33.5/8 77.6 NA Program IN T5DIM 1.0/.01 <10 28 2600 835 2600 /26 33.5/8 77.6 NA Program
10 T5DIM 1.0/.01 <10 28 2600 841 2600 /26 33.5/8 77.6 NA Program
JP T5H0 DIM 1.0/.03 <10 54 4450 830 4450 /134 63 /12.5 70.6 NA Program JO T5H0 DIM 1.0/.03 <10 54 4450 835 4450 /134 63 /12.5 70.6 NA Program JR T5H0 DIM 1.0/.03 <10 54 4450 841 4450 /134 63 /12.5 70.6 NA Program
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp Rated Output
Lamp Color
(Kelvin)
IES Output
(Lumens)
System
Input Watts
System
Efficiency
(lum/watt)
System
Lamp Life
(Hours)
Start Type
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • F1109
Job Information Type:
PHILIPS
LIGHTOLIIzir
Loading...