Connections: Wiring is via 18 gauge wire. All electrical connections for standard
configurations are plug-and-play via 6-wire cannon plug connections. Connections
are seated in end castings of fixfures, allowing for simulfaneous mechanical/ elecfrical coupling. Connecfors are male/female fherefore modules musf be insfalled
male to female, starting from the power feed end set.
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
2 3
Features
1. Housing: 18 gauge steel. 6" (15.24cm) cast aluminum end caps. No exposed
fasteners or hardware.
2. Lamping: 1 T5 fluorescent lamps per 4' (121.92cm) section. Lamps by Lightolier
degree shielding lengthwise. Blades are spaced 2.3" (5.84cm) O.C with a radius
that matches the housing. 1" (2.54cm) tall louver attaches to housing.
5. Optional Slotted Top Reflector: Precision die-formed anti-iridescent, highly
reflective aluminum.
All sfafic ballasfs have fhe following feafures:
• Elecfronic
• High Power Facfor
• Class A sound rafing
• Mefal can
Emergency Battery Pack: Emergency Battery packs are designed to operate
when normal building power is interrupted. The battery packs operate for a mini
mum of 90 minutes without any power via a rechargeable battery source. The pack
does not utilize the standard static ballast for any of its operation since the pack
carries its own pseudo ballast. For this reason, Lightolier does not recommend
remote mounting EM Packs because all of the socket wiring would need to carry
throughout the power feed end set. The EM batteries, even in their largest, most
expensive form, operate the fluorescent lamps at only half the lamp rated output.
Emergency battery packs are available in the following outputs:
• 450 Lumens (Standard)
• 635 Lumens
• 1100 Lumens
• 1375 Lumens
Emergency battery packs can be used for emergency egress lighting since all listed
packs operate for a minimum of 90 minutes, or can be used as momentary lighting
for emergency circuit power transitions. Smaller packs are recommended for this
purpose.
Dimming: T8 and T5H0 lamps are dimmed with two wire ballasts. T8 lamps can
be dimmed down to 5% and T5H0 lamps can be dimmed down to 1%. T5 lamps
require 5-wire dimming ballasts and can be dimmed down to 1%. A 5-wire power
feed will be required for T5 (non-HO) dimming.
Labels Included
UL, cUL,and IBEW
Mountings
Cable suspension is on 48" (121.92cm) and 96" (243.84cm) centers and consists
of a 4 1/2" (11.43cm) diameter canopy finished white enamel. A 1/16" (0.16cm)
diameter stainless steel aircraft cable accomplishes suspension and is adjustable
from 12" (30.48cm) to 36" (91.44cm). Power feed is 18-gauge SJT white cord. For
special circuiting consult factory.
Finish
Powder coated, baked enamel, white or aluminum, as specified. Custom colors
available, consult factory.
Ordering Instructions
Individual Fixtures:
1. Order number of MODULES required.
2. Order one POWER FEED END SET per MODULE.
Continuous Rows:
1. Determine run length.
2. Order the appropriate number of MODULES for the complete run.
3. Order one POWER FEED END SET for each run.
4. Order one CABLE ASSEMBLY per MODULE minus one per run.
5. For runs that exceed conductor ampacity ratings order the appropriate number
of SINGLE CABLE & CORD SETS.
When ordering no lamps provided by Lightolier, use Lamp code "Z".
SeriesLamping &
EG 1
Distribution
1 = 1 Lamp
4 = 1 Lamp,
Slotted Top
Reflector
BallastLampShieldingLengthVoltageFinish
See Ballast
Chart Below
P
See Lamp
Chart Below
r P
P = Parabolic
Louver
Module Ordering Specifications
Lamping and Distribution
1 = 1 Lamp
4 = 1 Lamp, Slotted Top Reflector
Ballast Specifications
CodeLamp TypeBallast Factor
FT51.00Program<10
GT5H01.00Program<10
IDim T51.00/.01Program<10
JDim T5H01.00/.03Program<10
Dimming: Advance Mark-10 standard (no additional wires required) for T8 and
T5H0 fixtures. 5-wire dimming required forT5 (non-HO) fixtures. Optional dimming
systems: Lutron ECO-10 and Hi-Lume (by others) require 4-wire modules and end
sets. Mark-7, ULT, DALI and Lightolier HDL require 5-wire power feed end sefs.
Energos can accepf ballasfs not to exceed 1.7" (4.32cm) wide by 1.2" (3.05cm)
high.
Start
Type
THD %
Shielding
P = Parabolic Louver
Length Voltage Finish
4 = 4ft (48") (121.92cm) 1 = 120VAC A = Aluminum
8 = 8ft (96") (243.84cm) 2 = 277VAC W = White
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
Options
(Blank)
P
4 = 4'(121.92cm)
8 = 8' (243.84cm)
CodeLamp TypeWattage
MT5282600*830
NT5282600*835
0T5282600*841
PT5544450*830
QT5544450*835
R
25°c Rating
1 = 120V
2 = 277V
Lamping Specifications
T5544450*841
A = Aluminum
W = White
Rated Output
(Lumens)
4= 4 through wires
5= 5 through wires
6= 6 through wires
D= Dual Switch
T= Tandem Switch
E= Emergency Pack
Color (K)
Feature Options (continued)
E = Emergency Battery Pack (E): Baffery packs provide 90 minufes of opera-
fion. Available lamp oufpufs: 450 Lumens (sfandard). Opfional: 635,1100 and 1375
Lumens. Sfandard Emergency wiring is fo have Baffery Pack operafing a single
lamp. All EM fixfures are wired as "swifched" and include 4fh fhrough wire for
fhe wall swifch (see diagrams). All fixfures and power feeds in fhaf run should be
ordered fo include a dedicafed 4fh fhrough wire fo carry fhe hot power all the way
through the run to the EM pack.
Consult Lamp and Ballast System data to determine Input watt requirements for
ballast used on project to determine loading for each run. Mulfiply fhe fötal num
ber of ballasfs by fhe Inpuf waffage per ballasf, and fo defermlne ampacify divide
fhe fötal watts by the system voltage. 10 Amps for 3-wlre end sefs, 7 Amps for
4-wlre and 5-wlre end sefs, maximum.
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
4' (121.92cm)
Module
4' (121.92cm) Run
8' (243.84cm) Run
12' (365.76cm) Run1111
16' (487.68cm) Run211
Single Cable & Power Cord: EGCC36
Single Cable & 4 Wire Power Cord: EGCC36X4
Single Cable & 5 Wire Power Cord: EGCC36X5
Because mosf ceilings are whife, all canopies ship as whife
unless specifically ordered otherwise.
Both CGK and CGKP ship with two types of clips
(sfandard and slot T).
Eor mounting fixtures directly to the T grid, order
one CGK per non-power suspension point and one
CGKP per powered suspension point.
The CGKP will Include a special canopy with flex
coupler, grid clips and addiflonal clips fo mounf fhe
juncflon box fo the top of the grid nearby. J-Box
and flex condulf provided by others.
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
Ballast and Lamp Ordering Combinations
Desgn.
Notes:
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania Specifications
When ordering no lamps provided by Lightolier, use Lamp code "Z".
The lumen value for the lamp (within a Lighting Design program) will be
the lES Output value shown on this table.