Philips EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E User Manual

...
Installation and Operating Manual
Fastrax
Dome Video Camera for Ceiling and Wall Mounting
EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E, EDC-142E2
1
3
Contents
1. Introduction ..............................................................................................................................................................................................................3
1.1 Features ...................................................................................................................................................................................................................3
2. Installation and Conguration ................................................................................................................................................................................... 5
2.1 Package Contents..................................................................................................................................................................................................... 5
2.2 Basic Conguration of Fastrax II Dome Camera System ............................................................................................................................................ 6
2.2.1 Single Multiplexer..................................................................................................................................................................................................... 7
2.2.2 Single User with Two Multiplexer .............................................................................................................................................................................. 8
2.2.3 Two Multiplexer with Slave Keyboard Controller........................................................................................................................................................ 9
2
Safety Instructions
• Read these safety instructions and the operation manual rst before you install and commission the camera.
• Keep the manual in a safe place for later reference.
• Protect your camera from contamination with water and humidity to prevent it from permanent damage. Never switch the camera on when it gets wet. Have it checked at an authorized service center in this case.
• Never operate the camera outside of the specications as this may prevent the camera functioning.
• Do not operate the cameras beyond their specied temperature, humidity or power ratings. Operate the camera only at a temperature range of -10°C to
+50°C and at a humidity of max. 90%.
• To disconnect the power cord of the unit, pull it out by the plug. Never pull the cord itself.
• Pay attention when laying the connection cable and observe that the cable is not subject to heavy loads, kinks, or damage and no moisture can get in. Do not attempt to disassemble the camera board from the dome.
• Do not attempt to disassemble the camera board from the dome.
• The warranty becomes void if repairs are undertaken by unauthorized persons. Do not open the camera housing. Maintenance and repair have to be
carried out only by authorized service centers.
• Do not use strong or abrasive detergents when cleaning the dome. Use a dry cloth to clean the dome surface. In case the dirt is hard to remove, use a mild
detergent and wipe gently.
NOTE: This is a class A digital device. This digital device can cause harmful interference in a residential area; in this case the user may be required
to take appropriate corrective action at his/her own expense.
1. Introduction
1.1 Features
The Fastrax II Keyboard Controller and the Fastrax II dome cameras make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and exible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs.
• Built-in 18x (23x,25x, 22x, 26x) times optical power zoom camera with True Night Shot function
• 240 Preset positions
• 8 Tours consist of Preset, Pattern, Auto-Scan and Tour itself can be programmed over 300 functions and Preset location. While moving, each Preset scan can be watched in smooth Vector Scan mode.
• 8 Auto Scan including vector scan (and 1 endless Auto Scan at EDC-144E)
• 4 Pattern (240seconds)
• 8 Privacy zone
• 8 Alarm input / 4 Aux out (NC & NO)
• Variable speed from 0.1°/sec to 90°/sec
Turbo speed is Max 360°/sec with Ctrl key pressed
Maximum speed is inversely proportional to the zoom ratio
• Maximum speed is 380°/sec when preset command.
• Programmable user preferences (alarm, preset, title, etc.)
• Up to 999 selectable camera addresses
• Built-in RS-485/422 receiver driver
• Clear bubble with black liner (shelter) for concealing the camera
• Optional Tinted Bubble, Indoor & Outdoor pendant housing with heater & blower, Indoor Flush Mount, Parapet mount & Roof Top mount
3
5
Alarm Input (up to 8)
<Sensor>
up to 255 multiplexer
up to 99 DVR
Alarm Output (up to 4)
up to 32 cameras
<Siren>
<Flashing light>
J-box
Master keyboard
up to 3 Slave keyboards
Figure 1 - Typical System Conguration
Figure 2 - Assemble bubble ring ass’y
push
remove camera window
push
Remove window Assemble bubble ring ass’y
bubble ring ass’y
screw
Note: It is recommended to remove camera window for improving picture quality when you assemble bubble ring ass’y.
4
2. Installation and Conguration
2.1 Package Contents
The package contains the following:
1x Fastrax II E (Dome Camera)
1x Bubble Ring
1x Instruction Manual (This Document)
3x Assembly Screws for Attaching Fastrax II E
3x Plastic Anchor
1x 10Pin Connector
2x 12Pin Connector
CAUTION: Be sure to have caution labels (E version only) on both body and base of the camera.
The dome camera is for use in surface mounting applications and the mounting surface should be capable of supporting loads up to 10lb (4.5kg).
The dome camera’s base should be attached to a structural object, such as a hard wood, wall stud or ceiling rafter that supports the weight of the dome camera.
Different version will not support alarm input and output.
Cable entry
Surface (ceiling)
LockUnlock
Figure 3 - Installation
Lock
Base
Align extruded tap in the base to the keyhole on the PCB in the body
Body
5
7
2.2 Basic Conguration of Fastrax II Dome Camera System
Power 24VAC
STP AWG #24
Alarm output
1 ~ 2
Sensor
Alarm input
up to 8
Siren
Light
Alarm output
up to 4
J-Box (Back) J-Box (Front)
BNC
Monitor
BNC
Alarm output
3 ~ 4
RS-485 Half Duplex mode: RX+, RX–
RS-422 Simplex mode: (RX+), (RX–) Duplex mode: (TX+), (TX–), (RX+), (RX–)
Alarm input
1 ~ 4
Power 24VAC
Dome1+
Dome1–
Alarm input
5 ~ 8
Up to 128 Dome cameras including 32 alarm mode can be connected at DOME2 port.
unshielded cable
DATA2 port should be connected in case that DOME2 port or DVR port are used.
Figure 4- Basic installation diagram
The dome camera must be installed by qualied service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.
unshielded cable
Keyboard controller
6
Rear
2.2.1 Single Multiplexer
AWG #24
BNC
Power
24VAC
Spot Monitor
Power 24VAC
Power 24VAC
Main Monitor
BNC
Multiplexer
J-Box (Back) J-Box (Front)
BNC
Rear
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
Figure 5 - Single Multiplexer
Keyboard controller
7
9
2.2.2 Single User with Two Multiplexer
AWG #24
BNC
1st Main Monitor
Power 24VAC
BNC
BNC
Power 24VAC
Power 24VAC
Spot Monitor
2nd Main Monitor
BNC
1st Multiplexer
J-Box (Back) J-Box (Front)
Keyboard controller
Figure 6 - Two Multiplexer
RS-485 (–) Pin No. 4
2nd Multiplexer
RS-485 (+) Pin No. 6
Spot output of the rst multiplexer to be connected to 16th input of the second multiplexer.
And rst spot output of the 2nd multiplexer to be connected to the spot monitor. You will see tthe picture of the selected camera (1-31) on spot monitor by selecting camera No. + Cam.
Rear
8
2.2.3 Two Multiplexer with Slave Keyboard Controller
AWG #24
BNC
1st Main Monitor
Power 24VAC
BNC
BNC
Power 24VAC
Spot Monitor
for Slave K/B
Power 24VAC
Spot Monitor
for Master K/B
2nd Main Monitor
BNC
1st Multiplexer
J-Box (Back) J-Box (Front)
Rear
Keyboard controller Master
Figure 7 - Two Multiplexer with Slave Keyboard Controller
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
Keyboard controller Slave
Spot output 1 of the rst multiplexer to be connected to 16th input of the second multiplexer.
n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.
2nd Multiplexer
Rear
9
11
2.2.4 Two Multiplexer with Slave Keyboard Controller (method 2)
AWG #24
BNC
1st Main Monitor
Power 24VAC
BNC
BNC
Power 24VAC
Spot Monitor
for Slave K/B
Power 24VAC
Spot Monitor
for Master K/B
2nd Main Monitor
BNC
1st Multiplexer
J-Box (Back) J-Box (Front)
Rear
Keyboard controller Master
Figure 8 - Two Multiplexer with Slave Keyboard Controller (method 2)
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
Keyboard controller Slave
Spot output 1 of the rst multiplexer to be connected to 16th input of the second multiplexer.
n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.
2nd Multiplexer
Rear
10
Addresses (ID) and protocol
selection switches
Figure 9 - Layout of Switches
Termination switches
2.3 Setting Unit for Termination
The device which is connected at end of line, whether it is a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.
SW1 1 2
Terminated ON ON
Not terminated OFF OFF
Figure 10 - Setting Unit for Termination
11
Loading...