Philips ED231 User Manual

5"
73/4"
Ceramalux®High Pressure Sodium Non-Cycling
1
100 Watt ED23
Featuring ALTO®Lamp Technology
2 (Clear) Lamp
w Ordering Information
Ordering Code ANSI Designation S54 Product Number 14740-5 Description High Pressure Sodium
Package Quantity 12
w Physical Characteristics
Bulb Size ED 231⁄2 Bulb Finish Clear Base Mogul Screw Maximum Overall Length (MOL) 73⁄4'' (197mm) Light Center Length (LCL) 5'' (127mm) Arc Length 1.3'' (33.4mm) Arc Tube Length 2.24'' (57mm) Arc Tube Material Aluminum Oxide Max. Permissible Bulb Temp. 400°C (752°F) Max. Permissible Base Temp. 210°C (410°F) Max. Bulb to Base Eccentricity 3° Max.Arc Tube to Base Eccentricity
C100S54/ALTO NC HPS 12PK
TCLP* Compliant Non-Cycling
w Operating Characteristics (Photometric)
Approx. Initial Lumens Approx. Mean Lumens Rated Average Life, Hours Correlated Color Temperature (CCT) CIE Chromaticity Approximate Color Rendering Index (CRI) 18 Efficacy (lpw) 100
1
2
4
3
10,000 9000 30,000
3, 5
2100 K x-.520, y-.420
w Operating Position
Universal
w TCLP*Characteristics
e (US EPA TCLP) Results
xicity Characteristic Leaching Pr
o
T
EPA Limit (mg/l) max 0.200 5.00 C100S54/ALTO Mercury (mg/lamps) max 3.4
NC HPS 0.087 <0.11
ocedur
Hg Pb
Philips Lighting Company
100
90
80
70
60
0
0%
Percent of Rated Average Life
4
Per cent –Approx. Initial Lumens
20 40 60 80 100
100
90
80
70
60
50
0
0%
Percent of Rated Average Life
4
Per cent –Approx. Initial Lumens
20 40 60 80 100
200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
pdated 09/05 TDS-147405
U
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
Division of Philips Electronics Ltd.
A
Ceramalux®High Pressure Sodium Non-Cycling 100 Watt ED231⁄2 (Clear) Lamp
Featuring ALTO®Lamp Technology
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Lamp Operating Voltage (rms) (Nominal)3. . . . . . . . . . . 65
Initial Lamp Voltage Range (rms)6. . . . . . . . . . . . . . . . . . 57–73
Lamp Operating Current (Amps) (rms) (Nominal). . . . 2.1
Maximum Lamp Starting Current (Amps) (rms) . . . . . . 3.2
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . 5 Minutes
Restrike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . 5 Minutes
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI S54
Ballast Open Circuit Voltage (Minimum) . . . . . . . . . . . . 110
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 Min., 4000 Max.
ulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . 1 Micro Second Minimum
P
ulse Frequency (Minimum)
P
ag Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
L
cuit Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
Lead Cir
um Operating Temperature. . . . . . . . . . . . . . . . . . -30°C
Minim
erence Ballast Impedance . . . . . . . . . . . . . . . . . . . . . 44 Ohms at 120V RIV
Ref
Maximum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Minimum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Maximum Voltage Increase by Fixture . . . . . . . . . . . . . . 4
Approximate Survival Curve
Approximate Lumen Maintenance Curve
for ALTO NC HPS Lamps:
for ALTO NC HPS Lamps:
Footnotes:
1) Measured at 100 hr ximate mean lumen output at 40% of lamp rated average life.
Appro
2)
3) Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
4) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per star t.
It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to var y considerably from the average.
5) Approximate color temperature in Kelvin degrees.
6) Measured with the lamp operating at rated watts. Measured lamp voltage will change as the ballast changes lamp wattage.
* The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure
WARNINGS, CAUTIONS AND OPERATING
UCTIONS
INSTR Sodium Lamps
“WARNING:These lamps must be operated
R
in fixtures designed for use with High Pressure Sodium lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A par tial vacuum in the outer b
Oper
uck.
is str
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
s. life.Approximate lumen values listed are for ver tical or horizontal operation of lamp.
1) If the outer glass bulb is broken, shut off power
or Ceramalux High Pressure
f
immediatel
y and remo
2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits
of operation.
B. For total supply load refer to ballast manufacturers
electrical data.
ulb may cause glass to fly if the glass
ating the lamp improper
ly may result in
Protect lamp base
3)
e atmospheres and excessiv
rosiv
cor
4) Replace the lamp if the outer glass bulb has been
atched, cracked or damaged in any way.
scr
e the lamp after it has cooled.
v
, socket and wiring against moisture,
e heat.
5) If a lamp bulb support is used, be sure to insulate y so as to avoid possible
icall
the suppor
t electr
decomposition of the bulb glass.
6) Do not use this lamp in a fixture which redirects a
substantial portion of the energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.
7) Take care in handling and disposing of lamps. If arc tube
en, avoid skin contact with any of the contents
is brok
agments.
or fr
8) The arc tube of this lamp contains sodium and
mercury. Dispose of in accordance with federal, state and local requirements.
Loading...