![](/html/cb/cbf0/cbf09ca52636425d2e81a0a0797621c43ca9f388287e1f3f87aaf3259eab5dc5/bg1.png)
C2 Series
Recessed Emergency Lighting
Page 1 of 2
C2125L2RT6
12. 0"
(30.5 cm)
4.4"
(11.3 cm)
6.0"
(15.2 cm)
24.0"
(61.0 cm)
15.6"
(38.7 cm)
Features
Illumination: Illumination
is provided by up to four
adjustable lamp heads. Choose
from round or rectangular
thermoplastic heads with
Par 36 sealed beam tungsten
or halogen, or wedge base
tungsten or halogen lamps.
Lamp heads are factory
installed. The suggested head
is Lightolier’s “R” series wedge
base tungsten round lamp
head.
Housing: Faceplate
constructed of 18 gauge steel
with a white epoxy powder
coat finish; backbox 20 gauge
steel. Up to four lamp heads
can be mounted on the unit
faceplate. Lamp head choices
include round or rectangular
white thermoplastic to match
housing. Designed for easy,
drop-in installation into
suspended ceilings. Additional
wire supports may be required
by local codes and are supplied
by others.
Operating Temperature
Range: Standard Location
65°F (19°C) to 85°F (30°C)
Electronics: 120/277 VAC
dual voltage input with surge-
protected, solid-state charging
circuitry provides for a reliable
charging system. Charging
system is complete with
low voltage disconnect, AC
lockout, brownout protection,
AC indicator lamp and test
switch.
Electrical Specifications:
0.150 A, 18 W max. (120 VAC)
0.065 A, 18 W max. (277 VAC)
Code Compliance
UL 924 listed. NFPA 101,
NEC, BOCA, OSHA and IBC
illumination standards. Chicago
Approved City Plan No. 1879E.
Warranty
Three year full electronics
warranty. One year full plus
four year prorated lead calcium
battery warranty. Five year full
plus five year prorated nickel
cadmium battery warranty.
Job Information Type:
Job Name:
Cat. No.:
Notes:
![](/html/cb/cbf0/cbf09ca52636425d2e81a0a0797621c43ca9f388287e1f3f87aaf3259eab5dc5/bg2.png)
Recessed Emergency Lighting
Ordering Information
C2
Series
C2 = Recessed
Emergency
Lighting Unit
Note
1) Some option combinations may impact UL listing. Consult factory for specifics.
2) 15 minute delay.
DC Voltage
1 = 6 V
2 = 12 V
Battery
6 V Lead Calcium
25L = 25 W Unit
50L = 50 W Unit
6 V Nickel Calcium
14N = 14 W Unit
25N = 25 W Unit
12 V Lead Calcium
50L = 50 W Unit
12 V Nickel Calcium
25N = 25 W Unit
50N = 50 W Unit
# of Heads
1= One
2 = Two
3= Three
4 = Four
Blank= No
Heads
Lamp Heads
6V Round Wedge Base
RT6 = 5.4 W Tungsten
RT7 = 7.2 W Tungsten
RT9 = 9 W Tungsten
RH7 = 7 W Halogen
RH10 = 10 W Halogen
RH12 = 12 W Halogen
12V Round Wedge Base
RT9 = 9 W Tungsten
RT12 = 12.5 W Tungsten
RT18 = 17.9 W Tungsten
RH12 = 12 W Halogen
C2 Series
Factory Installed Options
T1 = 120 VAC Time Delay
T2 = 277 VAC Time Delay
V = Voltmeter
A = Ammeter
F1 = 120 VAC Fuse
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
1
2
2
Page 2 of 2
Optics
Wall mounted 10' AFF, ‘RH12’ 6 V 12 W Halogen Lamps Represented
1 FC Average
10 ft.
.8 .8 .8 .9 .9 .8 .8 .7 .7 .7 .7 .8 .9 .9 .9 .8 .8 .8
1.0 1.1 1.2 1. 3 1.3 1.2 1.0 .9 .8 .8 .9 1.1 1.2 1.3 1.3 1. 2 1.0 1.0
1.1 1.2 1.4 1. 5 1.5 1.4 1.2 1.0
1.2 1. 2 1.5 1.6 1.6 1.4 1.2 1.0
1.0 1.0 1.1 1.2 1.3 1. 2 1.0 .9 .8 .8 .9 1.0 1.2 1.3 1.2 1. 2 1.1 1.0
.8 .8 .9 .9 .9 .9 .8 .7 .7 .7 .7 .8 .9 .9 .9 .9 .8 .8
Average initial footcandles at floor = 1.05
.9 .9
.9 .9
(fixture spacing)
1.0 1.2 1.4 1.5 1.5 1.4 1.2 1.1
1.0 1.2 1.4 1.6 1.6 1.5 1.3 1.2
18 ft.
6 ft.
Maximum initial footcandles at floor = 1.6
Minimum initial footcandles at floor = 0.7
Maximum to minimum ratio = 2.29
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/50/20. Lightolier is not responsible for site specific conditions that
may alter the results.
Philips Lightolier
e: lol.webmaster@philips.com
t: (508) 679-8131
w: www.lightolier.com
C2 Series May 29, 2012
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2012. All rights reserved.