Petsafe Drinkwell Pagoda Fountain User Manual

IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electrical appliances, basic safety precautions should
always be followed to reduce the risk of fire, electric shock and/or injury to
persons, including the following:
1) Read all the instructions before using the appliance.
3) To protect against electric shock, do not place cord or plug in water or other liquids.
4) Only use attachments recommended or sold by the manufacturer.
5) Do not use outdoors. FOR INDOOR HOUSEHOLD USE ONLY.
6) Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
7) Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been dropped or damaged in any manner. Call customer service immediately for further instructions.
8) For a portable appliance - To reduce the risk of electrical shock, do not place or store an appliance where it can fall or be pulled into a tub or sink.
9) Always unplug any appliance when not in use, before putting on or taking off parts and before cleaning. Never pull on the cord to remove the adaptor from the wall outlet.
10) Do not use an appliance for anything other than its intended use.
SAVE THESE INSTRUCTIONS
400-1584/1
1
PAGODA FOUNTAIN
Thank you for choosing the PetSafe® brand. You and your pet deserve a
companionship that includes memorable moments and a shared understanding
together. Our products and training tools promote a lifestyle of protection, teaching
and love; essentials that influence memories for a lifetime. If you have any questions
about our products or training your pet, please visit our website at www.petsafe.net or
contact our Customer Care Center at 1-800-732-2677. Please register your product
within 30 days of purchase at www.petsafe.net.
Table of Contents
Operating Instructions
DO NOT RUN DRY - FOR INDOOR HOUSEHOLD USE ONLY
1) Carefully remove all the fountain components from the packaging and set aside prior to assembly.
2) As with any electrical device, check the electrical cord for any tears or damage before use.
3) Place the foam filter around the pump by inserting the pump into the filter from the top, make sure the cord rests on top of the filter (Fig.1).
Important Safety Instructions.............................................
Components.......................................................................
Operating Instructions........................................................
Filters & Fountain Cleaning................................................
Pump Maintenance............................................................
Fountain Reassembly.........................................................
The Fountain & Your Environment.....................................
Manufacturer’s Safety Instructions.....................................
Components
Bowl
Filter Housing
Case
Foam Filter
Top
Charcoal
Filter
Inline Plug
70 oz. Capacity
11 12
Tower
Pump
1 2 3 6 8 9
4) Take the bowl and place the pump inside the rectangular indention. Make sure the circular opening on top of the pump is positioned in the bottom left corner (Fig. 2). The foam filter will be slightly compressed between the pump and the post. Press down on the pump to engage the suction cups. Once the pump is securely in place, feed the cord over and through the raised post and out the notch on the bottom side of the bowl (Fig. 3).
Fig. 2
Pump
Outflow
Fig. 1
Fig.3
Cord rests
on top
Bottom
Rubber
Cap
Rubber
Grommet
Adaptor
32
Operating
Operating
Instructions
5) Remove the extra slack from the cord and insert the rubber cap into the raised post. Make sure the cutout channel is aligned with the cord, then insert your finger and push all the way down (Fig. 4). Fold the top of the cap over the post to seal off the bowl (Fig. 5).
Fig. 5Fig. 4
NOTE: Always rinse the charcoal filter prior to use. A small amount of charcoal dust
may shed for the life of the filter, this is normal and not harmful to your pet.
6) Rinse the charcoal filter thoroughly in cold water to help remove any excess and loose charcoal dust. Once the filter is rinsed off, place inside the filter housing case with the larger side facing down (Fig.
6). The filter will only fit inside the case one way, if it does not fit, flip it over. Attach the lid to the filter housing case, press down until you hear it snap in place.
Instructions
9) Place the fountain in a desired location. If placing on carpet, tile or wood flooring, use a protective mat or other durable, water resistant surface. This will help protect your floor from any
splashing or spills caused by your pet.
10) Fill the fountain by pouring water directly into the bowl. Leave at least a half inch (1.27 cm) of space between the water level and the rim of the bowl to help control spills and splashing.
11) Make sure the cord, the adaptor and your hands are completely dry before you plug the fountain in. Connect the inline plug and make sure no silver is showing, then plug the adaptor into an electrical outlet.
12) Add water to the fountain as needed. Never let the water level fall below 1” (2.54 cm) in height or you may risk burning out the pump. Replacement pumps are sold separately by calling Customer Care at 800-732-2677 or online at www.petsafe.net.
7) Attach the filter housing case to the pump by inserting the raised notch into the circular opening on top of the pump (Fig. 7). The opening on top of the filter housing should be right next to the sealed raised post.
8) Align the tower with the rectangular indentation inside the bowl and carefully lower it until it rests flat. The rubber grommet will create a seal between the filter housing case and the tower.
Fig. 6 Fig. 7
54
Loading...
+ 4 hidden pages