Perlick CR24D14R, CR24D14L, CR24W14L, CR24W14R, CR24F12R Installation Manual

...
4
3
2
1
#5 MARRY THE TWO CABINETS UP USING (4) ATTACHMENT BRACKETS (1013719) AND PROVIDE HARDWARE. (8) #10 SCREWS (M50050-466) ARE USED TO ATTACH THE BRACKETS AT THE TOP OF THE UNIT AND (8) M6 THREAD
ITEM NO. PART NO
1
2
3
4
-
-
1010469
1013719-1
SIDE BY SIDE HEATER ASSEMBLY
BRACKET, ATTACHING, COLUMN,
DESCRIPTION
COLUMN-REFRIGERATOR
COLUMN-FREEZER
QTY
1
1
1
4
FORMING SCREWS ARE USED TO ATTACH BRACKETS TO
22 1/4"
THE FRONT AND REAR BASE PLATES OF BOTH UNITS.
5
6
7
1008781
M50050-466
1009975-1
SCREW, M6 X 12MM, THRD FORMING
#10X1/2" PH.TRUSS HD.SMS#410S
BRACKET, MOUNTING, MACHINE
8
11
1
D
8
9
10
6
A
4
M50095-122
1015035-1
1010546
SCREW, SHEET METAL,10-16 X 1/2
CENTER TRIM
M5X10 MACH SCR, LOW HEAD
2
1
6
D
9
CENTER TRIM PIECE IS FLUSH WITH THE CABINET FACE.
DETAIL A
SCALE 1 : 2
#3 BEFORE FULLY TIGHTENING SCREWS MAKE SURE
#1
3
ATTACH THE HEATER ASSEMBLY
TO THE COLDEST CABINET
WITH
(3) #10 SCREWS (M50050-466)
1 2
B
C
C
84"
B
B
C
ISOMETRIC VIEW
A
SW
10 9
#3 ATTACH CENTER TRIM PIECE (1015035-1) TO THE CABINET ON THE RIGHT USING (6) M5 SCREWS (1010546).
#2 ROUTE THE HEATER WIRE THROUGH THE HOLE IN THE BASE PLATE AND ATTACH TO WIRE RETENTION BRACKET (1009975-1).
#4
PLUG THE WIRE HEATER INTO AN OUTLET USING THE SUPPLIED POWER CORD.
SECTION B-B
SCALE 1 : 8
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1014974
4
4
5
B
5
49"
#5 REMOVE THE GRILLS ON BOTH UNITS TO FASTEN THE ATTACHMENT BRACKETS TO THE FRONT OF THE BASE PLATES
#2 INSTALL WIRE RETENTION BRACKET WITH (2) #10 SCREWS (M50095-122)
4
3
7
MATERIAL:
8
DETAIL C
QTY.:
SCALE 1 : 2
FINISH:
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
SIGNATURES
DRAWN BY:
UO
APPVD BY:
JMP
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES:
BREAK SHARP EDGES - .015 X 45° RADIUS SHARP FILLETS - .015 TO .031 HOLES:
.0135 THRU
.1260 THRU .2510 THRU .5010 THRU .7510 THRU
1.001 & UP:
CORPORATION. COPYRIGHT 2001 PERLICK CORPORATION. ALL RIGHTS RESERVED.
2
.125: .250: .500: .750:
1.000:
.012
A
REV.
DATE
12/12/2017 01/10/2018
.004 .005 .006 .008
.010
INITIAL RELEASE
DESCRIPTION
REVISIONS
12/12/2017
DATE
Perlick Corporation
Milwaukee, Wisconsin
TITLE:
DUAL INSTALLATION INSTRUCTIONS
WITH HEATER PANEL
REFERENCE:
PART NO.
1014974
PURCHASE REC.:
1
DWG NO.
SCALE = 1:16
1014974
SHEET 1 OF 1
TEC
APPROVED
A
Loading...