Congratulations on your purchase of a Perlick
commercial wine column refrigerator. This manual
has been prepared to assist you in the installation
of your column refrigerator and to acquaint you
with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer
can provide you with a list of qualied service
agents. For your own protection, never return
merchandise for credit without our approval.
We thank you for selecting a Perlick product
and assure you of our continuing interest in your
satisfaction.
SAFETY
PLEASE READ all instructions completely
before attempting to install or operate the unit.
Take particular note of the DANGER, WARNING
an CAUTION information in the manual. The
information is important for the safe and ecient
installation, operation and care of your Perlick unit.
Indicates a hazard that WILL
result in serious injury or
death if precautions are not followed.
Warranty Registration
To register your product, visit our web site at
www.perlick.com. Click on “Commercial”, then
“Resources”, then “Use and Care”, and then
“Warranty Registration Form”. You must complete
and submit this form or the installation date will
revert back to the ship date.
Please record the purchase date and the dealer’s
name, address and telephone number below.
Model Number: ________________________
Serial Number: _________________________
Purchase Date: _______________________
Dealer Name & Address
______________________________________
______________________________________
______________________________________
Phone Number__________________________
NOTE: See page 20 for full warranty details.
Indicates a hazard MAY
cause serious injury or
death if precautions are not followed.
Indicates a hazard where
minor injury or product
damage may occur if precautions are not
followed.
Read and understand all information in this manual before attempting the installation.
All electrical work must be performed by a qualied technician and
your claim immediately with the transportation
company. Perlick is not responsible for damage
in transit.
When moving the unit, be
sure to protect finished flooring with
appropriate material to avoid damage from
moving the appliance.
If unit has been laid on its
back or sides, place unit upright and allow
minimum of 24 hours before connecting the
unit. Failure to do so can aect the function
and performance of the appliance.
This appliance should be installed in a dry,
ventilated indoor location. The ambient
temperature of the location must be between
55°F (13°C) and 100°F (43°C) for optimal
performance.
eration is very heavy. To ensure safety and prevent home damage, the load-bearing capacity
of your oor must be 550 lbs for each CC24W
column being installed.
This product must be installed on a level oor
for safety and optimal performance. The base
must be at to ensure anti-tip brackets properly
function and that the refrigeration system is lev-
el. Any walls and surrounding furniture/xtures
need to be securely attached to the oor, wall
studs or concrete prior to installing the column.
To ensure proper performance, the air intake
(toe kick) must not be blocked. Perlick refrigeration is front-breathing, and covering the intake
will cause the system to overheat and fail.
Inspect the electrical cord
and plug for damage prior
to plugging the unit in.
If service is necessary,
repair work must be
performed by a Perlick authorized servicer.
Work done by unqualied individuals could
potentially be dangerous and will void the
warranty.
If unit has been laid on its
back or sides, place unit
upright and allow minimum of 24 hours before
connecting power. Failure to follow this
procedure may damage the compressor and
void the warranty.
Do not use or store
flammable liquids (ie;
gasoline) or vapors near the appliance.
is secured at all times with the door closed
until installed. Install as directed using anti-tip
brackets provided to prevent tipping.
Perlick columns are top
heavy. It is important that it
Take special care when
moving to prevent injury.
Installation must comply with all applicable
electrical codes. The electrical supply must be
located within the shaded area of the illustration
below. A separate circuit, servicing only this
appliance, is required. A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation. The outlet should
be placed in the hatched area dimensioned below.
Serious electrocution
hazard. Electrical grounding is required. This
appliance is equipped with a 3-prong
(grounding) polarized plug for your protection
against possible shock hazards. Failure to
comply with these electrical guidelines may
result in possible death or serious injury, re
or loss of property.
Never use an extension
cord to connect the unit to the electrical
source. Do not use a two-prong adapter or
remove the power cord ground prong.
The depth of each Perlick column is 24” (610) to
door face (not including the 3/4” overlay). Allow for
door panel thickness when planning the nished
opening depth. A minimum of 4” (102) nished
return is required on all sides of the opening. See
below for opening dimensions drawing.
It is important that the side walls of the niche are
plumb prior to installation. The minimum thickness
of both the side walls and the top wall must be
5/8” (16). The minimum thickness of the toe kick
panel must be 1/2” (13). A thickness of 3/4” (19)
is recommended.
Framed cabinets will require additional filler
material behind the face frame for attaching antitip brackets. Refer to the illustration below.
The anti-tip bracket and supporting hardware
is included with your unit. In the case of dual
installation, each individual unit must be outtted
with the included anti-tip brackets.
For drawings of the anti-tip bracket installation on
integrated unit, see below. For drawings of the
anti-tip bracket installation on freestanding units,
see page 8.
glasses and use other necessary protective
devices or apparel when installing or working
with anchors. Anchors are not recommended
for use in lightweight masonry material such
as block or brick, or for use in new concrete
which has not had sucient time to cure. The
use of core drills is not recommended to drill
Always wear safety
holes for anchors.
Verify there are no
electrical wires or plumbing in the area which
the screws could penetrate.
NOTE: Do not fasten anti-tip brackets to adjacent cabinetry until the cabinet has been leveled.
Anti-Tip Bracket Installation for Built-In Applications