Perlick BR48 Installation Manual

Page 1
INSTALLATION AND OPERATION INSTRUCTIONS
CUSTOM BACK BAR CABINET — SELF CONTAINED AND REMOTE
MODEL NOS.
BS Series BR Series
BS Series
IMPORTANT INFORMATION
Fill out the enclosed warranty card and mail to the Perlick Corporation to register the warranty. If the card is not returned, the warranty period will begin from the date the equipment is shipped from the factory.
This manual has been prepared to assist you in the installation of your Cabinet and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
BR Series
Table of Contents
PREPARING THE CABINET
Specifications......................................................2,3
List of Included Parts.............................................4
Tools Required.......................................................4
Plumbing................................................................4
Electrical................................................................4
Placing the Cabinet ...............................................4
Leveling the Cabinet ..............................................4
Installing Casters or Legs .....................................4
Installing the Base Plate........................................4
Refrigeration and Temperature Control.................5
Cleaning the Cabinet.............................................5
Cleaning Stainless Steel........................................5
Replacement Parts................................................6
Reversing Door Hinge...........................................7
Wiring Diagram......................................................8
WARNING: When lifting, the full weight of the cabinet must be supported. Lift from the cabinet base and not from the top. Improper lifting can result in severe damage to the cabinet.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Form No. Z2278
Page 2
Installation and Operating Instructions
Sizes and Specifications, Custom Back Bar Cabinets – Self Contained
MODEL NOS. BS60 BS84 BS108
NUMBER OF DOORS 2 Door 3 Door 4 Door CABINET Length 60” (1524) 84” (2134) 108” (2743) DIMENSIONS Depth 24 (mm) Height 34 CASE CAPACITY
(based on 12oz. Export bottle) 12.9 20.4 27.7
CONDENSING UNIT H.P. RUNNING LOAD –AMPS 6.3 8.1 8.3 Ship Wt. Lbs. (kg.) 380 (172) 490 (222) 630 (286) INTERIOR Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene. Floor pan and
Walls: Stainless steel. Includes pilasters, (2) vinyl coated shelves and floor rack per door, and interior lights. EXTERIOR: Front, back, top and sides stainless steel. Bottom galvanized steel. DOOR HINGING Stainless steel hinges with standard locations as illustrated. For special hinging specify
hinge locations starting from left to right. Field reversible. DOOR HARDWARE Door handles: Black vinyl with chrome ends. Lock finish: chrome REFRIGERATION R-134A capillary tube-type. Aluminum fin and copper tube evaporator, epoxy coated coil. Adjustable
temperature control. Self-defrosting. Pull-out condensing unit for service and cleaning.
Compressor left, standard. ELECTRICAL 1 1 5V, 60Hz., 1 phase AC. Furnished with 3-prong, 6 foot NEMA5-15 PC cord. Contact Perlick for other voltage/
frequency requirements. PLUMBING None required. Condensate evaporates automatically. INSULATION Foamed-in-place polyurethane, 2” walls, 1 OPTIONAL • Leg set • Compressor right Door finishes
ACCESSORIES & • Tapping kit • Brass hardware Black vinyl coated MODIFICATIONS • Laminated top • Caster sets Stainless steel
• Laminated ends • Base plates Customers choice of laminate
• Laminated grille • Floor access kit Prepared for field lamination
3
/4” (629) 243/4” (629) 243/4” (629)
1
/2” (876) 341/2” (876) 341/2” (876)
1
/4
1
2” top.
/
1
/3
1
/3
Glass door with black vinyl coated frame Glass door with stainless steel frame Glass door with laminated frame
6 3/16
[157]
OPTIONAL
FLOOR
ACCESS
KIT 2
Form No. Z2278
12
[305]
5 1/8
[130]
108” [2743] 4 DOOR
84” [2134] 3 DOOR 60” [1524] 2 DOOR
92 [2337] 4 DOOR 68 [1727] 3 DOOR 44 [1118] 2 DOOR
6 5/16
[161]
23 1/2
[597]
DOOR
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
19 7/8
[505]
DOOR
OPENING
R23 1/2
NOTE B
4 1/4
[107]
18 3/4 [476] BACK LINER
TO INSIDE OF
DOOR SILL
NOTE A: 3/4 NPT DRAIN EXIT NOTE B: 1 DRAIN ACCESS
31 1/4
[794]
DOOR
HEIGHT
OPENING
6 3/8
[163]
27 7/16
[697]
DOOR
24 3/4
[629]
7 3/4
[197]
4 3/16
[106]
22 3/4
[578]
7 3/16
1 1/8
[29]
2
[182]
34 1/2
[876]
NOTE A
Page 3
Installation and Operating Instructions
Sizes and Specifications, Custom Back Bar Cabinets – Remote
MODEL NOS. BR48 BR72 BR96
NUMBER OF DOORS 2 Door 3 Door 4 Door CABINET Length 48” (1219) 72” (1829) 96” (2439) DIMENSIONS Depth 24 (mm) Height 34 CASE CAPACITY
(based on 12oz. Export bottle) 12.9 20.4 27.7
AMPS .9 .9 .9 BTU/HR 1800 2200 2600 Ship Wt. Lbs. (kg.) 380 (172) 490 (222) 630 (286) INTERIOR Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene.
Floor pan: Stainless steel. Includes pilasters, (2) vinyl coated shelves and floor rack per door, and interior lights. EXTERIOR: Front, back, top and sides, stainless steel. Bottom galvanized steel. DOOR HINGING Stainless steel hinges with standard locations as illustrated. For special hinging specify
hinge locations starting from left to right. Field reversible. DOOR HARDWARE Door handles: Black vinyl with chrome ends. Lock finish: chrome REFRIGERATION Aluminum fin and copper tube evaporator, epoxy coated coil. ELECTRICAL 115 V, 60Hz., 1 phase AC. Contact Perlick for other voltage/ frequency requirements. PLUMBING Independent floor drain or condensate evap. pan is req’d. Optional 2 INSULATION Foamed-in-place polyurethane, 2” walls, 1 OPTIONAL • Leg set • Brass hardware Door finishes
ACCESSORIES & • Tapping kit • Caster sets Black vinyl coated MODIFICATIONS • Laminated top • Base plates Stainless steel
• Laminated ends • Floor access kit Customers choice of laminate
3
/4” (629) 243/4” (629) 243/4” (629)
1
/2” (876) 341/2” (876) 341/2” (876)
1
1
/2” top.
/8” I.D. floor access kit-left rear corner.
Prepared for field lamination Glass door with black vinyl coated frame Glass door with stainless steel frame Glass door with laminated frame
96 [2439] 4 DOOR 72 [1829] 3 DOOR 48 [1219] 2 DOOR
92 [2337] 4 DOOR 68 [1727] 3 DOOR 44 [1118] 2 DOOR
5-1/8
[130]
6-3/16
[157]
OPTIONAL
FLOOR
ACCESS
KIT 2
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
23-1/2”
[597]
DOOR
19 7/8
[505]
DOOR
OPENING
6-5/16
[161]
4-1/2
[107]
18-3/4 [476] BACK LINER
TO INSIDE OF
DOOR SILL
R23-1/2”
31-1/4
[794]
DOOR
HEIGHT
NOTE A 3/4 NPT DRAIN EXIT NOTE B 1 NPS DRAIN ACCESS
6-3/8
[163]
27-7/16
[697]
DOOR
OPENING
22-3/4
[578]
7-3/4
3-7/16
3
24-3/4
[629]
[197]
[87]
4-3/16
[106]
REFRIGERATION &
ELECTRICAL ACCESS
RIGHT OR LEFT
7-3/16
[182]
34 1/2
[876]
1-1/8
[29]
NOTE A
Form No. Z2278
Page 4
Preparing the Cabinet for Use
Parts List
(2) Shelves plus (1) Floor Rack-per door.
Shelf Clips.
Suggested Tools
#2 Phillips Screwdriver.
10” Crescent Wrench.
9
16” Allen Wrench.
/
5
/16” and 3/8” Hex Socket.
Power Drill or Driver.
Plumbing
No plumbing required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the side condensing unit compartment. Unit can be plumbed with a floor drain out rear right corner connection out side or bottom. Both drains are plugged and can be removed if needed.
3
4” NPT thread or bottom right 1” NPS thread
Placing the Cabinet
Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit.
For sanitation purposes, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor as shown by the figure at below.
CABINET
BEAD SILICON
SEALER (RTV)
FLOOR
Electrical
The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.
Uncrating and Inspection
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit.
Installing Casters or Legs
Attach four casters to the cabinet bottom; rigid cast­ers at the rear and swivel casters on the front. Use the supplied machine screws.
1
/4”- 20 x 3/4” hex head self-tapping
(Optional)
Leveling the Cabinet
When the cabinet is in place, check installation with carpenter’s level. When level front to back and left to right, accumulated water will drain out of cabinet evaporator drain.
Installing Base Plate (Optional)
Attach brackets to cabinet bottom in holes provided. Attach base plate to brackets. (See separate instructions, provided with kit). When returning cabinet to upright position, be careful not to bend brackets.
WARNING!
To avoid compressor damage,after returning cabinet to an upright position, let unit stand for 24 hours before plugging it in and running the unit.
Form No. Z2278
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
4
Page 5
General Information
Refrigeration and Temperature Control
The Single Door Cooler cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.
4
3
COLDER
2
1
OFF
5
6
COLD
Adjusting the temperature
The temperature control is inside the cabinet on the left-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.
Colder Temperatures:
Turn the adjusting screw clockwise (to the right).
Warmer Temperatures:
Turn the adjusting screw counterclockwise (to the left).
Temperature Control “OFF”:
Turn the adjusting screw completely counter­clockwise to the “O” position until a click is noted.
The condenser fan motor turns off and on with the compressor. The evaporator fan motor is on all the time.
NOTE:
Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted.
Cleaning the Cabinet
Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. NOTE: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.
Cleaning the Condenser
Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure efficient operation. CAUTION: Do not bend the fins while brushing the front of the condenser.
Condenser
The condenser (located behind the front grille cover) should be inspected every 30 days and cleaned, if necessary.
Failure to keep the condenser clean will cause a loss in condensing unit efficiency.
Recommended Cleaning Agents
JOB CLEANING AGENT* COMMENTS
Routine Cleaning Soap, ammonia, detergent Apply with sponge or cloth.
Can be used on all finishes.
Fingerprints and smears Areal 20, Lac-O-Nu, Lumin Wash, Provides barrier film to minimize
OCedar Cream Polish fingerprints. Can be used on all finishes.
Stubborn stains and Allchem Concentrated Cleaner, Rub lightly, using dry or damp Discolorations Samae, Twinkle, Zud Restoro, cloth in the direction of polish
Grade F or FFF Italian Pumice, lines on the stainless steel. Whiting or Talc, Liquid Nu Steel, Coppers or Revere Stainless Steel Cleaner, Lumin Cleaner, Sta-Clean, Cameo Copper Cleaner, Allen Polish Highlite, Penny-Brite, Copper Brite
*
Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.Omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on the package.
NOTE: Do Not Use Steel Wool or Scouring Pads to clean stainless steel.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
5
Form No. Z2278
Page 6
Replacement Parts — Custom Back Bar Cabinets
MODEL NOS. BS60 BS84 BS108
BR48 BR72 BR96
Condensing Units (BS Only)
Condensing unit 115 volt, 60 hz. C22647 C22646 C22646 Condensing unit 515301063 515301062 515301062 Compressor 513200314 513200003 513200003 Fan motor assembly 215315009 215315009 215315009 Condenser coil 15352019 15352019 15352019 Terminal board 219101538 219101538 219101538 Overload protector MRT20AGK5590 MRT22AGK5590 MRT22AGK5590 Relay 21351619 21351619 21351619 Capacitor 13556529 13556532 13556532
Evaproator Assembly
Self Contained (BS) complete 65555-1 65555-2 65555-2 Remote (BR) complete 65555-1R 65555-2R 65555-2R Evaporator coil (BS) & (BR) C17511-1EP C17511-2EP C1751 1-2EP Liquid & Suction line (BS) 65084 65085 65085
Fan blade 57699 57699 57699 Fan motor C15239A C15239A C15239A Evaporator fan guard 65557 65557 65557 Temperature control 61283 61283 61283 Bulb clamp C6634 C6634 C6634 Wire harness, compressor bottom 65560 65560 65560 Wire harness, evaporator 65561 65561 65561 Wire harness, light jumper 65538 65539 65540 Wire harness, mullion heater 65571 65572 65573 Light bulb 63821 63821 63821 Light bulb guard 65525 65525 65525 Light socket 63484 63484 63484 Light switch 65535 65535 65535 Lock 63762 63762 36762 Space, lock 63761-1 63761-1 63761-1 Lock rail 65432-24SS or 65432-24 65432-24SS or 65432-24 65432-24SS or 65432-24 Grille rail 65432-12SS or 65432-12 65432-12SS or 65432-12 65432-12SS or 65432-12 Condenser pan 65565-1 65565-1 65565-1 Condenser end panel 66215-1SS 66215-1SS 66215-1SS Grille, black 66210-12 66210-12SS 66210-12SS Grille, SS 66210-12SS 66210-12 66210-12 Condenser housing back 65435-12SS 65435-12SS 65435-12SS Evaporator, liquid & suction line cover 65576-1L 65576-2L 65576-3L Evaporator pan 65526-1 65526-2 65526-2 Door sill 65500-1 65500-1 65500-1 Door handle bracket 65189-1 65189-1 65189-1 Door handle C31409-1 C31409-1 C31409-1 Door gasket 66237-4 66237-4 66237-4 Cabinet hinge 65436-LBRT 65436-LBRT 65436-LBRT Cabinet hinge 65436-LBRB 65436-LBRB 65436-LBRB Hinge pin 63679-1 63679-1 63679-1 Hinge assembly, cabinet left side 65505L 65505L 65505L Hinge assembly, cabinet right side 65505R 65505R 65505R End shelf kit 57928 57928 57928 Center shelf kit 57929 57929 Left or right shelf 62307-2 62307-2 62307-2 Center shelf 62308-2 62308-2 Vertical partition 61830-1 61830-1 61830-1 Pilaster strip C19271-1 C19271-1 C19271-1 Shelf clip C15875 C15875 C15875
Replacement door RD-NL2 RD-NL2 RD-NL2
*
Contact Perlick Milwaukee for complete door replacement. Cabinet serial no. required.
*
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2278
6
Page 7
Reversing Door Hinge
g
Tools Required
Phillips Screwdriver.
#4 Allen Wrench.
Flathead Screwdriver or Putty Knife
Right Hinged Door
(as shipped from factory)
Operations to Perform on Cabinet
STEP 1:
Remove bottom hinge pin from assembly.
STEP 2:
Carefully lift and tilt out door assembly from the unit and set aside.
STEP 9:
Re-insert top hinge pin.
STEP 10:
Re-assemble lock rail from STEP #3
Bottom Hinge Bracket
Operations to Perform on Door
Step #14
Top Hinge Bracket
STEP 3:
Remove lock rail from cabinet, requires removal of four screws.
Remove these screws
STEP 4:
Remove top hinge pin. Remove top and bottom hinge brackets from the unit.
STEP 5:
Top Hinge Bracket
Bottom Hinge Bracket
Remove hinge bushing from bottom hinge bracket and assemble to top hinge bracket.
Hinge Bushin
STEP 6:
Taking care not to scratch the sur­face, remove hole plugs from the left hinge holes.
STEP 7:
Insert hole plugs into vacant right
Step #7
Step #6
hinge holes
STEP 8:
Re-assemble hinge brackets to unit. Bottom right bracket is assembled as the top left bracket. Top right bracket is assembled as the bottom left bracket.
Step #12 Step #11 Step #13
STEP 11:
Remove bottom door hinge bracket from door assembly and remove door hinge bushing from bracket. Re-assemble door hinge bracket to previous position, without bushing.
STEP 12:
Remove top door hinge bracket from door assembly and assemble door hinge bushing from STEP 11 to bracket. Re-assemble door hinge bracket to previous position with bushing attached.
STEP 13:
Remove handle and reposition in other set of pre-drilled mounting holes directly underneath..
STEP 14:
Remove lock retainer and install on opposite end of door..
STEP 15:
What was the door top is now the door bottom. Carefully lift the door onto the hinge brackets of the cabinet. The two hinge bushings should meet. reinsert the bottom hinge pin to complete the door switching operation.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
7
Form No. Z2278
Page 8
Wiring Diagram – Custom Back Bar Cabinets
[2] DOOR
MULLION HEATER MULLION HEATER MULLION HEATER
BLACK WHITE
EVAPORATOR FAN EVAPORATOR FAN
EVAPORATOR
HOUSING
GROUND WIRE
BLACK
GREEN
POWER CONNECTION
WHITE
WHITE
BLACK
WHITE
BLACK
GREEN
JUNCTION BOX
LIGHT SWITCH
BLACK
WHITE
BLACK
RED
CABINET
JUNCTION BOX
PRESSURE SWITCH
BS Series Self-Contained
[3] DOOR [4] DOOR
RED
WHITE
BLACK
WHITE
LIGHT LIGHT LIGHT
THESE WIRES CAPPED IN
SINGLE CABINET
INSTALLATIONS
NOTE:
FIELD WIRING FROM CABINET JUNCTION BOX TO CONDENSING UNIT MUST COMPLY WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.
CONDENSING UNIT
FIELD INSTALLED
2, 3 and 4 Door
BR Series Remote 2, 3 and 4 Door
LIGHT
[2] DOOR
MULLION HEATER MULLION HEATER MULLION HEATER
RED
BLACK
LIGHT SWITCH
WHITE
BLACK
LIGHT LIGHT LIGHT
WHITE
BLACK WHITE
EVAPORATOR FAN EVAPORATOR FAN
WHITE
[3] DOOR
[4] DOOR
LIGHT
THERMOSTAT
CONDENSING UNIT
POWER CONNECTION
BLACK
WHITE
GREEN
WHITE
BLACK
GREEN
JUNCTION BOX
BLACK
RED
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2278
8
Loading...