Perlick BC36LT Service Manual

Installation
& Operation Manual
Flat Top Bottle Cooler
BC Series
C
US
Form No. Z2295 Rev. 01.16.2015
Flat Top Bottle Coolers Installation & Operation Manual
JOB
AREA
ITEM NO.
MODEL NO.
BC24 SERIES
BC36 SERIES
BC48 SERIES
BC48LT SERIES
BC60 SERIES
C
BC60LT SERIES
BC24SS shown
BC48SS shown
BC72 SERIES
BC72LT SERIES
BC96 SERIES
* BC36 Model Only
MODEL NUMBERS BC24 BC36 BC48/BC48LT BC60/BC60LT BC72/BC72LT BC96
LENGTH (mm) 24” (610) 36” (915) 48” (1219) 60” (1524) 72” (1828) 96” (2438)
INTERIOR CU. FT. (m3) 3.75 (0.10) 7.83 (0.22) 11.68 (0.33) 15.53 (0.44) 19.38 (0.55) 27.08 (0.77)
CASE CAPACITY (12 bottles) 5.5 9.75 17.2 21 28.3 41
CASE CAPACITY (12 cans) 7.0 16 25 30 36 58
CONDENSING UNIT H.P. 1/5 1/5 1/4 1/4 1/3 1/3
AMPS 3.2 3.0 5.2 7.0 6.9 7.6
SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235)
INTERIOR All models have stainless steel walls and oor.
Choice of black, stainless steel and all stainless.
EXTERIOR
TEMPERATURE (Approx. factory settings)
DOORS (Siding) Stainless steel top and bottom pans. Die cast handle. Option locks.
ELECTRICAL 115V, 60Hz, 1 Phase. Furnished with 6 foot rubber plug-in cord (115V model only). Also available in 230V, 50Hz, 1 phase AC.
PLUMBING No drain required. Condensate evaporates automatically.
INSULATION 2 inch foamed-in-place polyurethane insulation.
REFRIGERATION R134a capillary tube/type with hermetric condensing unit. Pulls out for service and cleaning.
VENTILATION 2’ model is front vented, all other models require 2” clearance from wall on either left end or back of cabinet for proper air ow.
OPTIONAL ACCESSORIES
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized. Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized. All Stainless Option: Front, ends, back and bottom are all stainless steel.
38ºF/Standard Model. 30ºF Low-Temp Model
• Floor racks • Casters • Bottle opener and receiver • Interior light
• Bin dividers • Speed rails • Wine temperature (specify red or white)
• Interior light kits • Adjustable legs • Roller basket shelving • Door locks
US
* Shown with optional opener and receiver.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 2
Flat Top Bottle Coolers Installation & Operation Manual
DANGER
WARNING
CAUTION
TABLE OF CONTENTS
Cabinet Specications ............................................................................................................................. 2
Installing
- Uncrating and Inspection...................................................................................................................... 4
- Plumbing .............................................................................................................................................. 4
- Electrical ............................................................................................................................................... 4
- Adjusting Partitions ............................................................................................................................... 4
- Installing Casters and Legs .................................................................................................................. 4
- Placing the Cabinet .............................................................................................................................. 4
- Sealing to the Floor .............................................................................................................................. 4
Temperature Control ................................................................................................................................ 5
Cleaning the Cabinet ............................................................................................................................... 5
Wiring Diagrams ................................................................................................................................... 7/8
Replacement Parts ............................................................................................................................... 8/9
GENERAL INFORMATION
Introduction
This manual has been prepared to assist you in the installation of your Bottle Cooler and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, call Perlick at 1-800-777-7267 or your dealer who can provide
you with a list of qualied service agents. For
your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
SAFETY
PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING an CAUTION information in the manual. The
information is important for the safe and efcient
installation, operation and care of your Perlick unit.
Indicates a hazard that WILL result in serious injury or
death if precautions are not followed.
Warranty
To register your product, visit our web site at www.perlick.com. Click on “Commercial”, then “Service”. Click on the link “Warranty Registration Form”. You must complete and submit this form or the installation date will revert back to the ship date.
Please record the purchase date and the dealer’s name, address and telephone number below.
Model Number: ________________________ Serial Number: _________________________ Purchase Date: _______________________ Dealer Name & Address __________________ ______________________________________ ______________________________________ Phone Number__________________________
Indicates a hazard MAY cause serious injury or
death if precautions are not followed.
Indicates a hazard where
minor injury or product damage may occur if precautions are not followed.
Printed in USA 3
IMPORTANT!
Read and understand all information in this manual before attempting the installation.
All plumbing and electrical work must be performed by a qualied technician and
conform to all applicable state and local codes.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Flat Top Bottle Coolers Installation & Operation Manual
CAUTION
CAUTION
PREPARING THE CABINET - FLAT TOP BOTTLE COOLERS
Uncrating and Inspection
Remove all crating material. Carefully inspect cabinet for hidden damage. If damage is
discovered, le your claim immediately with the
transport company. Perlick is not responsible for damage in transit.
Plumbing
No plumbing connections are required. Condensate from the cooling coil automatically evaporated through a condensate pan located in the condensing unit section.
Electrical
The cabinet must be connected to a separately
fused power source (see Electrical Specication Plate afxed to unit) in accordance with National
and Local electrical codes.
Do not attempt to operate the equipment on any
other power source than that listed on the
Electrical Specication Plate.
Placing the Cabinet
To assure maximum performance, fresh air must
be allowed to circulate through the machinery compartment. It is important to allow at least two inched of clearance at the back or left end of the cabinet. Do not place anything in front of
the cabinet that would obstruct air ow at these
grilles. Do not place the unit in an unventilated small room.
Removing the factory
installed back clearance spacers without providing proper left side grill clearance for compressor air ow will void the
warranty.
Cabinet should be leveled.
For sanitation purposed, it may be necessary to
seal the base of the cabinet to the oor. This can
be accomplished by laying a bead of silicone sealant along the base of the cabinet as shown
by the gure below (gure 1).
Adjustable Partitions & Shelving
Perlick Bottle Coolers may be provided with adjustable partitions and shelving which will accommodate various bottle sizes.
■ Remove bottles and cans from their cases before placing in cooler to ensure proper
air ow.
■ On 2’ and 3’ models keep air intake open for
proper circulation.
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in
holes provided. Use the supplied 1/4” - 20 hex
head self-tapping machine screws. If unit is tipped
on its back for an extended period of time, wait
24 hours after unit is uprighted to plug the unit in.
Cabinet
Bead Silicon Sealer (RTV)
Floor
Figure 1. Sealing Cabinet to Floor
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 4
Flat Top Bottle Coolers Installation & Operation Manual
HOW TO OPERATE - FLAT TOP BOTTLE COOLERS
Temperature Control
An adjustable temperature control is located inside the Bottle Cooler on the evaporator fan panel
assembly. It is factory set at approximately 38˚F for standard refrigeration and approximately 30˚F
for low temperature models. Make adjustments as detailed below to attain the desired temperature. NOTE: A temperature setting that is too low will not allow enough condensing unit “off” time to maintain a frost-free coil.
Colder Temperatures: Turn the adjusting screw clockwise (to the right)
Warmer Temperatures: Turn the adjusting screw counterclockwise (to the left).
Temperature Control “OFF”: Turn the
adjusting screw completely counterclockwise to the “O” position until a “click” is noted.
The condenser fan motor turns off and on with compressor. The evaporator fan motor runs continuously.
Cleaning the Condenser
■ The condenser (located behind the from grille) should be inspected every 30 days,
and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efciency, or compressor failure.
Cleaning the Doors
■ Doors should be periodically removed from the cabinet and inspected for a buildup of foreign materials, such as syrups, beer, etc. Buildups on the underside of the doors, along with the cabinet breaker strips on
which they ride, will cause them to bind, and therefore, not function as designed. If dirty, these surfaces should be cleaned with a mild detergent and water and then coated with a silicone lubricating material. Aerosol silicone sprays can be obtained locally at most hardware or automotive stores.
To remove doors:
■ With door closed, lift it upward by its handle and slide forward until doors clears the cabinet top. Use the reverse procedure to
reinstall the doors.
Cleaning the Cabinets
■ Use a damp cloth with a mild detergent and
water to clean the inside and outside of the cabinet. Dry thoroughly. Do not allow cleaning agents or large amounts of water to go down the drain. Use an acceptable stainless steel polish to clean all stainless steel surfaces. Never use steel wool or scouring pads to clean stainless steel.
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain chemicals or objects which will cause stainless steel corrosion.
STAINLESS STEEL ENEMY
■ Steel wool or steel scouring pads
■ Cherry/Orange/Olive juice
■ Chlorine Bleach
■ Sharp Objects
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 5
Flat Top Bottle Coolers Installation & Operation Manual
WIRING DIAGRAM - FLAT TOP BOTTLE COOLERS
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 6
Flat Top Bottle Coolers Installation & Operation Manual
WIRING DIAGRAM - LOW-TEMP BOTTLE COOLERS
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 7
Flat Top Bottle Coolers Installation & Operation Manual
REPLACEMENT PARTS - FLAT TOP BOTTLE COOLERS
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 8
Flat Top Bottle Coolers Installation & Operation Manual
REPLACEMENT PARTS - FLAT TOP BOTTLE COOLERS
MODEL NOS. BC24 BC36
BC48/
BC48LT
BC60/
BC60LT
BC72/
BC72LT
BC96
Item Description Part Numbers
1 Complete condensing unit C22648 C22648 C22647 C22646 C22646 C22646
2 Replacement compressor, R134a 513307046 513307046 513200314UA2 513200003 513200003 513200003
Condensing unit fan motor assy. 515315009 515315009 515315009 515315009 515315009 515315009
Terminal Board 519100088 519100088 519100088 519100088 519100088 519100088
Overload Protector 513634530 513634530 US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1
Relay 513514069 513514069 US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1
Start capacitor N/A N/A US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1
3 Condensate pan 64537 64626-1 64626-1 64626-1 64626-1 64626-1
4 Evaporator fan motor(s) C15239A C15239A C15239A C15239A C15239A C15239A
5 Evaporator fan motor bracket 65671-1 65671-1 60988-1 60988-1 60988-1 60988-1
6 Evaporator fan motor blade 63461 63461 57699 57699 57699 57699
7 Evaporator fan guard 65666 65666 65557 65557 65557 65557
8 Evaporator coil 64785-1EP C17511-1EP C17511-1EP C17511-2EP C17511-2EP C17511-2EP
9 Temperature control 61283 61283 61283 61283 61283 61283
10 Bottle opener C6713-1 C6713-1 C6713-1 C6713-1 C6713-1 C6713-1
11 Bottle cap receiver C17332SS C17332SS C17332SS C17332SS
12 Front grille 66498-3A 65662-1A 65662-A1 65662-1A 65662-1A 65662-1A
13 Rear grille/panel 66498-1 65662-3 65662-3 65662-3 65662-3 65662-3
14 Top assembly RT-SL2 RT-SL2 RT-SL2 RT-SL2 RT-SL2 RT-SL2
15 Top wiper gasket 63671-24 63671-36 63671-48 63671-60 63671-72 63671-96
16 Door assembly RD-SL2 RD-SL2 RD-SL2 RD-SL2 RD-SL2 RD-SL2
17 Lock assembly 63940 63940 63940 63940 63940 63940
18 Vertical partition 65503 66441 66441 66441 66441 66441
19 Roller basket N/A 66442-1 66442-1 66442-1 66442-1 66442-1
20 Wide shelf N/A 64811-1 64811-1 64811-1 64811-1 64811-1
21 Narrow shelf 64809-1 64809-1 64809-1 64809-1 64809-1 64809-1
22 Bottom oor rack (wide) 64814-1 64814-1 64814-1 64814-1 64814-1 64814-1
23 Bottom oor rack (narrow) N/A N/A 64815-1 64815-1 64815-1 N/A
24 Shalf bracket 65653-24 65653-36 65653-48 65653-60 65653-72 65653-96
25 Door handle 63931 63931 63931 63931 63931 63931
26 Light Bulb C15046 C15046 C15046 C15046 C15046 C15046
27 Light socket 63484 63484 63484 63484 63484 63484
28 Evaporator drain pan 65670-24 65670-36
65526-1SL 65526-2SL 65526-2SL 65526-2SL
C17332SS C17332SS
ITEMS NOT SHOWN
Wire harness, main 65043-1 65043-1 65044-1 65044-1 65044-1 65044-1
Suction line/cup tube heat
exchanger with drier
Mullion assembly N/A N/A 66551 66551 66551 66551
Refrigerant charge (oz. R134a) 6.0 8.5 9.0 9.0 9.0 9.0
65072 65072 65073 65075 65074 65220
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 9
Flat Top Bottle Coolers Installation & Operation Manual
8300 West Good Hope Road • Milwaukee, WI 53223 •
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Toll Free 800.558.5592 • Fax 414.353.7069 • www.perlick.com
Printed in USA 10
Loading...