Pentax RTH7400D Owner's Manual

RTH7400D
Programmable Thermostat
OWNER’S GUIDE
For assistance with your Honeywell product, please visit www.honeywell.com/yourhome toll free at 1-800-468-1502.
or call Honeywell Customer Care
Read and Save these Instructions
Patents Pending ® U.S. Registered Trademark © 2004 Honeywell International Inc. All Rights Reserved
69-1726-1
Contents
Prepare for Installation ............................................................ 3
Follow Important Instructions .................................................. 5
Remove Old Thermostat ......................................................... 6
Follow Special Instructions...................................................... 7
Label Old Thermostat Wires ................................................... 10
Mount New Wallplate to Wall .................................................. 11
Connect Wires to New Wallplate............................................. 15
Install Batteries........................................................................ 23
Attach New Thermostat to Wallplate ....................................... 24
Configure Installer Setup......................................................... 26
Customer Assistance .............................................................. 62
Limited One-Year Warranty..................................................... 63
69-1726—1 2
Step 1. Prepare for Installation
e
.
Ó
e
/yourhome
G
R
G
R
C
C
O
UW3U
W3
8
on
ead and save
ese
s
t
é
1. Check that the following items are included:
WALLPLATE
THERMOSTAT
MOUNTING SCREWS (2) AND WALL ANCHORS (2)
OWNER'S GUIDE
WIRE LABELS
CAUTION CARD
OWNER'S GUIDE
M
R
th
instruction
CAUTION
TURN OFF POWER to system at the furnace, or at the fuse/circuit
breaker panel before you begin.
Match the letter of your old thermostat wire with the terminal of th
corresponding letter on your new thermostat or base
fusibles-interruptor
V/V
V/V
R
ll.com
M2227
If any of the items shown above are missing, call Honeywell Customer Care at 1-800-468-1502 before returning the thermostat to the store.
3 69-1726—1
Step 1. Prepare for Installation (Cont)
2. Check that you have everything required for the
installation:
• Two AA alkaline batteries
• No. 2 Phillips screwdriver and standard pocket screwdriver
•Drill
• Drill bit—use 3/16 in. for drywall; use 7/32 in. for plaster
• Level (optional)
• Hammer
•Pencil
• Electrical tape
69-1726—1 4
Step 2. Follow Important Instructions
1. Do not connect the wires to the new thermostat
based on wire color because damage can occur to the heating and/or cooling system.
These Installation Instructions explain later how to use the enclosed wire labels to correctly mark the wires connected to your old thermostat.
OLD THERMOSTAT
YELLOW
WHITE
R
RED
W
NEW THERMOSTAT
!
DO NOT WIRE
BASED ON
WIRE COLOR.
M22034
G
GREEN
RC
Y
ORANGE
5 69-1726—1
Step 3. Remove Old Thermostat
1. Turn off power at the heating and/or cooling system
or fuse/circuit breaker panel.
2. Remove the cover from the old thermostat.
3. Remove the old thermostat from the wall or wall-
plate. Do not remove the wires.
OLD THERMOSTAT
WALLPLATE
Y
G
C
W
THERMOSTAT
R
.
1
8
.2
.9
.7 .5
L
O
N
R
.4
G
E
.25
.3
COVER
M22036
MERCURY NOTICE
If you are replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash.
Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old thermostat containing mercury in a sealed tube.
69-1726—1 6
Step 4. Follow Special Instructions
1. If you have two C and/or C1 wires connected to
your old thermostat, do not connect them to your new thermostat.
2. Disconnect the C and/or C1 wires. Make sure they do not touch each other or any other wires.
3. Wrap the bare end of each C and/or C1 wire with electrical tape.
OLD THERMOSTAT
Y
W
G
C
LETTER DESIGNATION
SCREW TERMINAL
WIRE
R
C
DO NOT CONNECT TO NEW THERMOSTAT
7 69-1726—1
WIRE HOLE
M22201
Step 4. Follow Special Instructions (Cont)
4. If you have only one C and/or C1 wire connected to
your old thermostat, connect this wire to C on the new thermostat.
OLD THERMOSTAT
Y
G
R
C
CONNECT TO THE "C" ON THE NEW THERMOSTAT
69-1726—1 8
W
LETTER DESIGNATION
SCREW TERMINAL
WIRE
WIRE HOLE
M22223
Step 4. Follow Special Instructions (Cont)
5. If you find any wires not connected to your old
thermostat, do not connect them to your new thermostat.
6. Wrap the end of the wires that are not connected with electrical tape.
OLD THERMOSTAT
LETTER DESIGNATION
Y
G
C
R
W
SCREW TERMINAL
WIRE
R
WIRE HOLE
WIRES NOT CONNECTED – DO NOT CONNECT TO NEW THERMOSTAT
M22040
9 69-1726—1
Step 5. Label Old Thermostat Wires
1. As you disconnect each wire, use the enclosed wire
labels to wrap a wire label around each wire that matches the letter designation. Do not allow the wires to fall into the wall opening after the wires are disconnected.
2. Remove any remaining part of the old thermostat
from the wall.
OLD THERMOSTAT
Y
W
Y
G
G
RC
R
C
When connecting the wires to the new thermostat, refer to the wire labels. Do not connect wires to your new thermostat based on the color of the wire.
69-1726—1 10
WIRE LABEL
W
R
LETTER DESIGNATION
SCREW TERMINAL
WIRE
R
WIRE HOLE
M22039
Step 6. Mount New Wallplate to Wall
1. Separate the wallplate from the thermostat as
shown.
WALLPLATE
WIRE HOLE
THERMOSTAT
M22267
11 69-1726—1
Step 6. Mount New Wallplate to Wall (Cont)
2. Pass the labeled wires through the wire hole on the
wallplate.
WALL OPENING
WIRE HOLE
PLATE
L
WAL
LABELED WIRES
69-1726—1 12
M22279
Step 6. Mount New Wallplate to Wall (Cont)
3. Position the wallplate on the wall with the arrow
pointing up. Level the wallplate (for appearance only) and mark the two mounting holes with a pencil.
PLACE LEVEL ON
LEVEL
WALLPLATE
M22292
SUPPORT TABS
MARK MOUNTING HOLES (2)
13 69-1726—1
Step 6. Mount New Wallplate to Wall (Cont)
4. Move the wallplate aside and drill holes at the
locations marked on the wall. Drill 3/16 in. holes for drywall or 7/32 in. holes for plaster.
5. Tap the wall anchors into the drilled holes until even
with the wall surface.
DRILLED HOLES (2)
WALLPLATE
M22293
6. Position the wallplate over the wall anchors.
7. Insert the mounting screws into the wall anchors.
Check leveling, if desired, and tighten the mounting screws.
WALL ANCHORS (2)
MOUNTING SCREWS (2)
69-1726—1 14
Step 7. Connect Wires to New Wallplate
1. Match the labeled wires to the letter designations
on the wallplate.
2. Select the correct letter designations to follow for
your system. If you have a standard heating and/or cooling system, use the CONVENTIONAL letter designations. If you have a heat pump system, use the HEAT PUMP letter designations to wire the new thermostat.
M22294
See table on page 30 to help you determine if you have a CONVENTIONAL or HEAT PUMP system.
15 69-1726—1
Step 7. Connect Wires to New Wallplate (Cont)
3. If wires are to be connected to both Rc and R,
loosen the Rc and R screw terminals and remove the metal jumper wire.
4. If only one of the terminals, Rc or R, is to be
connected, leave the metal jumper wire in place.
TERMINAL BLOCK
SCREW TERMINALS
LETTER DESIGNATIONS
C
G
Y
O/B
RC
R
WALLPLATE
METAL JUMPER WIRE
69-1726—1 16
M22295
Step 7. Connect Wires to New Wallplate (Cont)
5. Loosen the screw terminals. Insert the labeled
wires into the holes on the side of the terminal block that match the letter designations. Tighten the screw terminals.
6. If any of the labeled wires do not match the letter
designations, see next page for wire connections.
LABELED WIRES
TERMINAL BLOCK
SCREW TERMINALS
CONVENTIONAL LETTER DESIGNATIONS
RC
C
G
Y
W
R
G
Y
W
C R
R
INSERT WIRE IN HOLE
WALLPLATE
WIRE HOLE
M22325
17 69-1726—1
Step 7. Connect Wires to New Wallplate (Cont)
7. Compare letter designations on your old and new
thermostats. Use the information below if you are wiring a CONVENTIONAL System. Use the information on page 20 if you are wiring a Heat Pump system.
CONVENTIONAL letter designations
on the new thermostat
1
RC
1
R
W
Y
G
C
Y2
W2
Do not connect more than one wire to each terminal. Be sure to read the notes referenced in the numbered triangles above. These numbered notes appear on the next page.
69-1726—1 18
Possible letter
designations on
the labeled wires
or R
RC
or RH, 4, V
R
or W1, H
W
or Y1, M
Y
or F
G
or C1, X, B
C
Y2
W2
2
2
3
M22208
4
Step 7. Connect Wires to New Wallplate (Cont)
NOTES FOR CONVENTIONAL HEATING AND COOLING SYSTEMS
1
If wires will be connected to both RC and R on the new thermostat, remove metal jumper wire between R wire in place if only one of the terminals, R on the new thermostat.
If wires were connected to both R and RH terminals on the old
2
thermostat, remove metal jumper wire between R new thermostat. Connect the old R to the new R to the new R.
3
If two C and/or C1 wires were connected to the old thermostat, do not connect them to the new thermostat. Wrap the bare end of each wire separately with electrical tape and do not use.
4
If one C and/or C1 wire was connected to the old thermostat, the wire should be connected to the "C" letter designation on the new thermostat.
C and R. Leave metal jumper
C or R, will be connected
C and R on the
C and the old RH
M22246
19 69-1726—1
Step 7. Connect Wires to New Wallplate (Cont)
8. Compare letter designations on your old and new
thermostats. Use the information below if you are wiring a HEAT PUMP system.
HEAT PUMP letter
designations on the
new thermostat
1
RC
R
O/B
Y
G
C
L
E
AUX
M22210
2
3
3
4
AUX, W1, W or
Possible letter
designations on
the labeled wires
VR or V or
R
H or B,
O
Y1 or M or
Y
F or
G
X or B,
C
F or
L
X2 or X,
E
W2
Be sure to read the note referenced in the numbered triangles above. These numbered notes appear on the next page.
69-1726—1 20
Loading...