Pentax HHT-149-HD Installation Manual

IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked over by persons in the household.
3. Always turn the air purifier controls to the OFF position and unplug from the wall outlet when not in use.
4. To disconnect the air purifier, press the Power button ( ) to turn the unit off,
grip the plug
and pull it from the wall outlet.
Never pull by
the cord.
5. Do not use any product with a damaged cord or plug or if product malfunctions,
is dropped or damaged in any manner.Keep the cord away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do not cover with thro
w rugs.
Arrange cord such
that it will not be tripped over.
9. Do not use air cleaner where combustible gases, va
pors or an oxygen rich environment
are present.
10. Do not expose the air purifier to rain, or use near water
, in a ba throom, laundry area or
other damp location.
11. The air purifier must be used in its upright position.
12. Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or dama
ge to the air purifier
. Do not
block air outlets or intakes.
13. Locate air purifier near the outlet and a void using an extension cord.
14. This appliance has a polarized plug (one blade is wider than the other).
T
o reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOTattempt to defeat this safety
feature.
15. A loose fit between the ACoutlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
16. Do not sit,
stand or place heavy objects on the
air purifier.
17. Disconnect po
wer supply before servicing.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier With Any Solid-State Speed Control Device.
The sealed UV bulbs contain a small amount of mercury.Dispose of these items at household hazardous waste collection sites only. If the UV bulb breaks, do not vacuum or handle with your bare hands.
HEPA CLEAN
WHISPER QUIET AIR PURIFIER WITH UV LIGHT
Model HHT-149-HD
The Honeywell trademark is used by Kaz, Inc.under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 1
YOUR AIR PURIFIER
HOW YOUR AIR PURIFIER WORKS
ODOR ABSORPTION
This model air purifier incorporates a 4-stage cleaning system to help clean the air that passes through the unit (Fig.1).
Stage 1: Washable (Permanent) Particle Pre-F
ilter or
Replaceable Odor Absorbing Filter
Stage 2: UV light that can be turned on or off Stage 3: 99% HEPA-Type Filter Stage 4: Electronic Ionizer tha
t can be turned on or off
depending on your personal preference
UltravioletLight
Washable Pre-Filteror Replaceable OdorAbsorbing Filter
Fig. 1
Control Panel
HEPA-
Type
Filters
(2)
Washable Pre-filter (1) OR Optional Odor Reducing Pre-filter
Rear
Grille
This air purifier includes a special odor absorbing pre-filter(s) packed in the product box. In order to enjoy the benefits of enhanced odor control, replace the washable pre-filter that is already in the air
purifier with the odor absorbing pre-filter . For optimal performance,the pre-filter(s) is(are) wrapped in plastic to keep it fresh. Pre-filter replacement timing will be approximately 3 months, depending on use. You can purchase replacement B Plus pre-filters from your local Home Depot store or visit www.homedepot.com.If you have any questions, contact Kaz Consumer Services at 1-800-447-0457.
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 2
OPERATION
Powering Up: (Fig. 3)
• Plug the air purifier into a grounded, working outlet. Once the unit is plugged in, the back-lit Power Button icon ( ) will blink for 12 seconds indicating the unit is ready for operation.
• When the Power Button is pressed the following will take place:
°
The LCD display and buttons will light up.The Oscillation, On/off,Timer, and Timer +/– button lights will turn off after 3 seconds.The LCD light will turn off after 8 seconds if no buttons are pressed.
°
The UV feature turns on.
°
The Ionizer feature turns on.
°
The air purifier will operate at a medium cleaning power level for a few seconds and then automatically change to a low level.
°
The continuous Run display turns on and rotates.
Fig. 3
INSTALL HEPA-TYPE FILTERS
The HEPA-Type Filters are supplied within the air purifier.They are wrapped to ensure purity.
• Make sure the air purifier is turn off and unplugged.
Remove the rear grille by pressing the notch on the top of the rear grille and pulling the grille towards you (Fig. 2).
• Remove the filters by gently pushing along the edge of the filter frame and pulling it forward. Repea t for the second filter.
• Remove the protective wrap from the filters.
• Place the filters back into the air purifier housing and snap the rear grille back into place.
NOTE: The pre-filter needs to be in position along the rear grille before snapping the grille back into place.
NOTE:
The Top filter must be securely in place in order for the unit to operate.
Fig. 2
SET-UP
• Select a firm, level and fla t location. For best airflow,locate the unit at least 3 feet (1 M) from an y wall or furniture.
• When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. If the unit is placed on a light colored carpet, a small ma t or rug should be used underneath to prevent permanent staining.This is especially important in homes with contamination from smoking, fireplaces or where candles are burned.
• Ensure the exit grille (front of the unit) faces away from the closest wall or furniture.
• Ensure no grilles are blocked.
Ionization on/off button
UV on/off button
Filter reset button
UV bulb reset button
Power button
Cleaning power +/- button
Oscillation button
Timer +/– button
Timer on/off button
LCD display
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 3
°
The filter status display turns on. (Note: The 1
st
segment is always
filled in.Additional segments will fill in as the filter gets dirty.)
°
The “filters”and “UV Bulb”lights will be green. (Note: if they are red, this indica tes that the filters must be cleaned or UV bulbs replaced.)
Changing the Cleaning Power Setting:
• This model has 12 air cleaning settings for specialized cleaning capability.
To increase the cleaning power, press the (+) button and to decrease the cleaning power, press the (–) button. The cleaning power display “segments”will increase when power is increased and vice versa.
• Use a higher setting if you want to clean your room at a higher rate and use a lower setting for quieter operation.
Ionizer, UV and Oscillation Options:
• Press the ionizer ( ),UV ( ), or oscillate ( ) buttons to turn these functions on or off.
The ionizer button will be back-lit to indicate ionization is taking place.The UV button will be back-lit and the blue UV indicator light will illuminate when the UV feature is on. (Note: UV bulbs are inside the product and the actual UV light cannot be seen.) The oscillate button will be back-lit and the unit will oscillate when the oscillation feature is on.
NOTE: If you have asthma symptoms or other breathing disorders that can be triggered by the presence of an ionizer,
we
recommend that you do not activate the ionization feature. Timer Operation:
• Once the air purifier is turned on, it can be programmed to turn off automatically after a set amount of time (up to 18 hours).
• Press the Timer on\off button ( ). The default time of “9 hr” will appear in the timer display (F
ig. 4).
• If you want to increase or decrease the amount of time in which the product will shut off, press the Timer (+) or (–) buttons.
• To turn off the timer mode, just press the Timer on\off button ( ).
NOTE: Removing the rear grille or turning off the unit will cancel the timer operation.
Filter Clean Indicator:
• The HEPA-T
ype filters and pre-filter should be checked about ever
y 3 months depending on use.The Filter Status display shows the approximate time left until the HEPA-Type filters need to be cleaned or replaced.
• When the Filters need to be cleaned or replaced,all of the Filter Status segments will be filled in and the Filters button LED will change from green to red (Fig.5).
• Clean or replace the HEPA-Type filters and pre-filter (see Cleaning/Replacing instructions) and then press and hold the Filters button for 5 seconds or until the light changes from Red to Green.The filter status bar will revert back to showing only one bar.
Fig. 4
Fig. 5
OPERATION
(CONTINUED)
OPERATION
(CONTINUED)
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 4
OSCILLATION FEATURE
DUAL UV LAMP OPERATION
• Press the UV button to turn the Lamps on or off (Fig 7).
• The lamps will light and you will see a faint blue glow along the top of the unit.This is a visual effect to let you know that the UV feature has been turned on.The UV bulbs are located inside the product and can’t be seen during normal operation.
• The UV button will be illuminated on the control panel.
NOTE: Removing the rear grille or turning the unit off will cancel the UV Lamp function.
To help circulate fresher, cleaner air throughout the room,this unit has an oscillation feature.
• To turn oscillation on or off, simply press the Oscillation ( ) button (Fig 6).
Fig. 6
Fig. 7
This model is equipped with long-life HEPA-Type filters.You have the option of cleaning your HEPA-Type filters or replacing them, depending on your personal preference.
To Clean Your HEPA-Type Filter:
• Air purifier should be turned off and unplugged prior to cleaning filters.
• Remove the rear grille from the air purifier by pushing down on the release tab at the top of the grille and pulling the grille a
way from the unit.
• DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE HEPA-TYPE FILTER.
• Remove filters from the unit. DO NOT IMMERSE FIL
TERS IN WATER.
• It is recommended that you use a vacuum cleaner that has a HEPA filter built into it.If a HEPA filter vacuum is not available, you should vacuum your HEP
A filter outdoors to keep the particles from getting
recirculated in the air in your home.
• To vacuum-clean the filter,hold the filter and run a vacuum cleaner with a nozzle or brush attachment along the filter to pick-up the dirt and particles (Fig.8). Repeat along the entire surface of the HEPA­Type filter.
• Note:The filter may still be discolored even after vacuum cleaning it.This is acceptable and will not affect performance.
• After vacuuming the filter, place it securely back into the air purifier housing and sna p filter grille into place.
• Press and hold the “Filters”button to re-set the indicator light.
CLEANING/REPLACING THE HEPA-TYPE FILTERS
Fig. 8
NOTE: If the odor reducing pre-filter is used in lieu of the permanent washable pre-filter, it will need to be replaced approximately every 3 months.
OPERATION
(CONTINUED)
OPERATION
(CONTINUED)
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 5
These cleaning intervals are intended as guidelines only.Performance of any filter media is dependent upon the concentration of contaminates going through the system. High concentrations of contaminates such as smoke will reduce the useful performance of the filter.
NOTE: The HEPA-Type filters are not washable.
To Replace Your HEPA-Type Filters:
You can purchase Honeywell replacement HEPA-Type filters for your air purifier if you prefer to replace the filters vs. c
leaning them. Replacement HEPA-Type filters may be available at your local Home Depot store or can be ordered directly at www.homedepot.com.If you have any questions, contact Kaz Consumer Services at 1-800-447-0457.
CLEANING/REPLACING THE HEPA-TYPE FILTERS (CONTINUED)
• Air purifier should be turned OFF,
and unplugged prior to replacing filters.
• Remove the rear grille from the air purifier by pushing down on the release tab at the top of the rear grille and pulling the grille away from the unit (Fig 9).
• Remove protective wrap from filter(s).
• Note the arrows on the filter frame – snap new filters into place with the arrows facing toward the unit. Install bottom filter first, then top filter.Filters must snap in place in order for the unit to operate properly.
• Re-install the rear grille by inserting the lower tab of the grille into the tab slot near the bottom of the air purifier. Push the top into place until you hear a “sna p” (Fig 10).
• Plug unit back in. Unit is read y for use.
replacement filters may be available from the Home Depot store where you purchased your air purifier, or can be ordered directly from Home Depot at www.homedepot.com.
If you have any questions, contact Kaz Consumer Services at 1-800-477-0457.
FILTER INSTALLATION INSTRUCTIONS
Fig. 9
Fig. 10
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 6
The pre-filter helps pick up large airborne particles that enter the rear grille.This pre-filter can be periodically removed and shaken to clean it.Alternatively,it can be rinsed by hand under warm water (Fig. 11). Let the pre­filter air dry completely before inserting back into the unit (Fig.12). If you need to replace this item, please call 1-800-477-0457 or visit www.kaz.com.
OPTIONAL: Changing the Odor Absorbing Pre-Filter
If you have chosen to use the odor absorbing B Plus filter that came with your air purifier,
it will lose its effectiveness for odor adsorption over time and will need to
be replaced. To purchase replacement pre-filters, visit your local Home Depot store or
order directly from www.homedepot.com.If you have any questions, contact Kaz Consumer Services at 1-800-477-0457.
If using the odor absorbing filter, it is recommended tha t you store the original washable pre-filter in the event that you decide to use it in the future.
To insert it into the unit, simply place securely into the rear grille in lieu of standard pre-filter as shown in figure 12.
NOTE: The odor absorbing pre-filter is not washable.
Fig. 11
MAINTAINING YOUR WASHABLE PRE-FILTER
Fig.12
• After about six to nine months of continuous use, the
UV bulbs must be replaced.
• When it is time to replace the bulbs, the UV Bulb
indicator light (Fig. 13) will change from green to red and the display will show a message (Fig. 13).
• To replace the bulb cartridge take the following steps:
°
Be sure to turn off and unplug your air purifier.
°
Remove the rear grille and the upper HEPA-Type filter (Fig.14).
°
Remove the UV bulb by pulling it from the unit (Fig.15). Dispose old UV Bulb cartridge only at household hazardous waste collection sites.
°
Insert a new UV bulb (HUV-145).Make sure it is completely inserted into the main unit. (Contact Kaz Consumer Rela tions at 1-800-477-0457 to order new UV replacement bulbs.)
°
Replace the HEPA-Type filter and rear grille.
°
Plug the air purifier back into an electrical socket and turn the air purifier on.
°
Press and hold the UV Bulb button for 5 seconds or until the light turns from red to green and the UV bulb related message in the display is cleared (Fig.16) .
NOTES:Bulb cartridge is not intended for use with any other product or purpose. This unit is equipped with a safety interlock switch.
The unit will not operate while the rear grille is removed.
REPLACING THE ULTRAVIOLET (UV) BULBS
Fig. 13
Fig. 14
Fig. 15
Fig. 16
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 7
We recommend that you clean the air purifier at least once every 3 months and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER,WAX POLISH,
OR ANY CHEMICAL SOLUTION.
If your Air Purifier will not be used for more than 30 days,we recommend:
• Remove the HEPA-T
ype Filters from the unit.
• Place the HEPA-Type Filters in a plastic bag, seal the bag and store with the unit.
CLEANING AND STORAGE
My filter bar says my filter is still relatively clean but when I checked my filter, it was really dirty
In conditions where smoke, pets or air with a lot of contaminants are present it is possible tha t the filter could be dirty sooner than indicated on the indicator.The filter life indicator on your unit runs on a timer and if there are more particles in your air than in an average home, your filter could capture airborne particles sooner than indicated on the display.The indicator is intended to be used as a guideline and individual environmental conditions will vary.
My unit will not turn on.
The air purifier has safety features to ensure that the unit is ready for operation. Check to make sure both HEP
A-type filters are installed flush to the air purifier. Check to make sure the rear cover is
installed flush with the unit and is locked in place.
When do the UV bulbs need to be replaced?
The “Replace UV Bulb”message and light will turn on after 6-9 months of continuous use, so the bulbs should be replaced at this time.
My Air Purifier is making noise and the air output is less.
What’s wrong?
The filters may be dirty.High amounts of contaminates can block the pores in the filter and stop the air from moving through it.The filters should be cleaned or replaced.
How long should I run my Air Purifier?
For best results,you should opera
te your Air Purifier 24 hours a day.This unit will be more effective
when doors and windows are closed.
Can I wash my HEPA-Type filter?
No.Washing the HEPA-Type filter will destroy it.
How does the UV check light work?
The UV check light will change from green to red when it is time to change the UV bulbs. Follow the instructions located in
“Replacing the ultraviolet (UV) bulbs”.
FREQUENTLY ASKED QUESTIONS
REPLACING THE ULTRAVIOLET (UV) BULBS
(CONTINUED)
NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose.
Lamp contains mercury.Manage in accordance with disposal laws. See www.lamprecycle.org or call 1-800-895-8842.
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 8
To order a replacement odor reducing pre-filters and HEPA-Type filters , go to www.homedepot.com.If you have any questions, contact 1-800-477-0457.
HEPA-Type Filter :Model HRF-C2 Odor Absorbing Pre-Filter :Model HRF-B1
Washable Pre-Filter:T.3024 Replacement UV bulbs (2 pack): Model HUV-145
REPLACEMENT FILTERS / UV BULBS
CONSUMER RELATIONS
Mail questions or comments to:
Kaz, Incorporated Consumer Relations Dept. 250 Turnpike Road Southborough, MA 01772
Call us toll-free at: 1-800-477-0457 E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM,PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO PRY OPEN THE AREA OF THE AIR PURIFIER WHERE THE MOTOR IS LOCATED, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY. PLEASE FOLLOW THE OPERATING INSTRUCTIONS CLOSELY.
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 9
You should first read all instructions before attempting to use this product.
A. This 5 year limited warranty applies to repair or
replacement of product found to be defective in material or workmanship.
This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.KAZ IS NOT LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL D
AMAGES
OF ANY NA
TURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.Some jurisdictions do not
allow the exc
lusion or limita
tion of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction.This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in ma
terial
or workmanship.
C. This warranty does not cover dama
ge resulting
from any unauthorized a
ttempts to repair or from any use not in accordance with the instruction manual.
D. This warranty DOES NOT cover the washable
pre-filter or the HEPA-T
ype filters, except for
material or workmanship defects.
E. Return defective product to Kaz, Incorpora ted
with a brief description of the problem. Inc
lude proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number.
You must prepay shipping charges.We suggest having tracking or delivery confirmation. Send to:
In U.S.A.:
Kaz,
Incorpora
ted Attn: Returns Department 4755 Southpoint Drive Memphis,TN 38118 USA
In Canada:
Kaz Canada,
Inc.
Attn:
Returns Department 510 Bronte Street South Milton, ON L9T 2X6 Canada
5 YEAR LIMITED WARRANTY
The ionizing process used by the air purifier (when the optional ionizer is activated) produces small amount of ozone as a byproduct.The air purifier complies with the U.S. Government limits for acceptable levels of ozone (less that 50 parts per billion by volume of air circula
ting through the product). People with a history of respiratory problems or heart/lung disease should consult a physician prior to using the ionizing feature of this product.
This product is California ARB (Air Resource Board) certified and complies with Federal ozone emission limits.
FREQUENTLY ASKED QUESTIONSIMPORTANT NOTE
© 2010 Kaz, Inc. All Rights Reserved.
PN: 31IMT149191
HHT-149-HD_OM.qxd 3/4/10 9:44 AM Page 10
Loading...
+ 21 hidden pages