BENEFITS
APPLICATION/SIZING
INSTALLATION TIPS
OPERATION TIPS
EV9347-20
High Flow CSR Plus-XC²
Delivers premium quality water for combination applications
High Flow CSR Plus-XC²: EV9347-20
High Flow CSR Plus-XC²: EV9347-20
EC210 Prefilter Cartridge: EV9534-26
EC210 Prefilter Cartridge: EV9534-26
SS-IMF Cartridge: EV9799-32
SS-IMF Cartridge: EV9799-32
One system provides premium quality water to high flow fountain, coffee and ice machines
New and improved Micro-Pure II media inhibits the growth of bacteria
Ideal where extreme water conditions demand larger capacity filters and surge tank to meet peak demand flow requirements
Reduces chlorine taste and odor and other offensive contaminants that can adversely affect the taste of beverages
Precoat submicron technology reduces dirt and particles as small as 1/2 micron in size and reduces health contaminants such as cysts
20" prefilter captures larger dirt particles
Remote mounted SR-X System with SS-IMF cartridge inhibits limescale buildup in ice machines and coffee brewers
Sanitary cartridge replacement is simple
NSF Certified under NSF/ANSI Standards 42 and 53
Choose a mounting location suitable to support the full weight of the system when operating
Use 3/4” water line
Fountain equipment connections are made to the outlet part of the system before the SR-X system
Coffee brewer and ice machine connections are made after the SR-X feeder; a tee is required
Install vertically with cartridges hanging down. Allow 2-1/2” clearance below the cartridge for easy cartridge replacement
Flush cartridges by running water through flushing valve for five minutes at full flow
Change cartridges on a regular 6 month preventative maintenance program
Change cartridges when capacity is reached or when pressure falls below 10 psi
Change SS-IMF cartridge before Hydroblend™ compound is completely used up
Change prefilter cartridge when excessively dirty
Always flush the filter cartridge at time of installation and cartridge change
For multiple equipment and combination applications
High volume installations
XC² cartridges provided for additional capacity
Rated Capacity: 48,000 gallons
Overall Dimensions: |
29.69”H x 31.58”W x 6.75”D (excludes tank and SR-X)
Inlet connection: 3/4”
Outlet connection: 3/4”
Service Flow Rate: Maximum 6.7 gpm (25.4 Lpm)
Rated Capacity: 48,000 gallons
Pressure Requirements: 10 - 125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35 - 100°F (2 - 38°C)
High Flow CSR Plus-XC²
XC² Precoat Replacement Cartridge
No electrical connection required
Shipping Weight: System is packed in two boxes and can be shipped via UPS. Box 1, System: 42 lbs.; Box 2, Surge Tank: 28 lbs.
Operating Weight: 50 lbs. system; 60 lbs. tank
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
Everpure water treatment systems (excluding replaceable elements) are covered by a limited warranty against defects in material and workmanship for a period of five years after date of purchase. Everpure replaceable elements (filter cartridges and water treatment cartridges) are covered by a limited warranty against defects in material and workmanship for a period of one year after date of purchase. See printed warranty for details. Everpure will provide a copy of the warranty upon request.