Pentair Everpure PBS-400 Installation Manual

EVERPURE® PBS400 WATER FILTRATION SYSTEM
SISTEMA DE FILTRACIÓN DE AGUA PBS400 PBS400 SYSTÈME DE FILTRAGE D’EAU
©2013 Pentair Residential Filtration, LLC www.pentairaqua.com
Thank you for purchasing an Everpure by Pentair commercial­grade water filtration system for your home. With your Everpure by Pentair system, you get premium quality water direct from your tap that’s great-tasting, healthful and convenient for you and your family.
PRODUCT SPECIFICATIONS
For Cold Water Use Only
Temperature Range: 35-100°F (2-38°C)
Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
ENGLISH
Service Flow Rate: 2.2 gpm (8.3 Lpm)
Capacity: 3,000 gallons (11,355 L)
1
3
4
5
1
6
7
2
TOOLS REQUIRED FOR INSTALLATION
Phillips Screwdriver
Adjustable Wrench
Tape Measure
Pencil
BASIC INSTALLATION INSTRUCTIONS
1. Open Carton & Inspect Parts
Installation Parts
Key Description Part No.
1 QL3 Filter Head EV927082 2 PBS-400 Filter Cartridge EV927086 3 2 Locking Washers EV306204 4 2 Screws EV306196 5 3/8-inch MPT x 3/8-inch FTP Elbow EV310852 6 (2) 3/8-inch x 1/2-inch Unions EV312251 7 (2) 3/8-inch x 3/8-inch Unions EV312250 8 Tubing, 3/8-inch Braided EV312249 9 Plumber Tape EV312119
10 Everpure Filter Timer EV314160
2. Verify Under-Sink Mounting Location
Measure 20 inches from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.
DIMENSION Width
PBS-400 5 inches 20 inches 5 inches
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
Mounting
Height
Depth
8
10
9
2
20 inches
2 EVERPURE
PBS-400 Water Filtration System
BASIC INSTALLATION INSTRUCTIONS
CONTINUED
3. Mount Filter Head Under Sink
NOTE: Two sets of unions are included to connect to the 3/8-
inch head connections. If your existing braided tubing has 1/2-inch connections, use the 1/2-inch x 3/8-inch unions instead of the 3/8-inch x 3/8-inch unions. You will have 2 extra fittings with either installation. The following instructions are for a typical installation using 1/2-inch supply lines.
A. Apply plumber tape to the small threads of one Union
Fitting and screw into the open end of the Elbow. Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.
B. Apply plumber tape to the threads of the Elbow Fitting
and screw into the inlet (left) side of the Filter Head. Hand tighten only.
C. Apply plumber tape to the small threads of the second
Union Fitting, and screw into the right side of the filter head in the same manner.
D. Securely mount the filter head on the cabinet wall using
the enclosed mounting screws and washers.
4. Connect Inlet Water Supply
E. Locate and close the cold water shut-off valve under your
sink. Open cold water line of faucet to release water pressure.
F. Unscrew and disconnect the braided tubing on top of cold
water shut-off valve.
G. Attach one end of the new braided tubing to the top of the
cold water shut-off valve.
H. Attach the other end of the new Braided Tubing to the inlet
side of the filter head (Union & Elbow Fittings).
3
A
D
C
B
4
ENGLISH
F
E
H
G
5
I
5. Attach Filtered Water To Cold Line of Faucet
I. Attach open end of existing Braided Tubing to Union Fitting
on outlet side (right) of new Filter Head. Hand tighten to avoid damage to fittings.
6. Install And Flush Filter Cartridge
J. Lift handle of the build-in shut off (QC Valve) on the Head. K. Hold Head firmly with one hand. L. Align cartridge lug with label on filter Head. M. Insert filter Cartridge—Push upwards. N. Turn it to the right—About 1⁄4 turn—Until rotation stops. O. Open cold water valve and check for leaks up to Inlet
Elbow Fitting. P. Open Water Faucet (not pictured). Q. Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridges for at least 3 minutes to
remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more that one week, please contact Pentair Technical Support for assistance: (800) 279-9404
R. Activate Filter Timer by pinching bubble until you feel a
change in resistance as the Filter timer “pops.” Within a few
seconds, a thin RED line will appear in the white window
showing the Timestrip® has been activated. Peel away
backing and adhere to desired location. When the white
window is completely filled with RED, it is time to replace
your product.
6
J
K
L
Label
M
Lug
Q
O
N
EVERPURE
PBS-400 Water Filtration System 3
HEALTH CLAIM PERFORMANCE
WARNING:
Cysts
Lead
CLASSIFIED BY UL
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
ENGLISH
Substance
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 98%
Particulate, Class I particles
0.5 to <1 µm
Standard 53—Health Effects
Cyst
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 94.1% 97.2%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.9% 98.9%
Influent
Challenge
Concentration
at least 10,000
particles/mL
Minimum
50,000/L
Max.
Permissible Product Water Concentration
Reduction
Requirements
≥ 85% 99.8%
99.95% 99.99% 99.99%
Minimum
Reduction
NOTE: This installation must comply with all applicable state
and local regulations. NOTE: Maximum working pressure 125 psi. NOTE: Do no use with water that is microbiologically unsafe
or unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on waters that may contain
filterable cysts. NOTE: Testing was performed under standard laboratory
conditions, actual performance may vary. NOTE: This drinking water system must be maintained
according to manufacturer’s instructions, including
replacement of filter cartridges. Suggested retail
$134.99.
CALIFORNIA PROPOSITION 65 WARNING
Average
Reduction
This System has been Tested & Certified by WQA against Std. 42 & 53 as verified and substantiated by test data for the reduction of:
This Filter System has been Tested & Certified by the WQA against NSF/ANSI Std. 42,53, 372 & CSA B483.1
Std. No. 42—Aesthetic effects
Chemical Reduction
Chlorine Taste & Odor
Mechanical Filtration
Nominal Particulate Class I
Std. No. 53—Health effects
Chemical Reduction
Lead
Mechanical Filtration
Cyst
EPA Est. No. 002623-IL-002
State of California Department of Public Health
Water Treatment Device
13-2213
Trademark/Model Designation Replacement Elements
EverPure PBS-400 PBS-400
Manufacturer: Pentair Residential Filtration, LLC.
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants
Organic Contaminants None
Rated Service Capacity 3,000 gallons Rated Service Flow: 2.2 gallons per minute
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems for cyst reduction may be used on disinfected waters that contain filterable cysts.
Certificate Number
Date Issued: December 5, 2013
Conditions of Certification
This product contains chemicals known to the
State of California to cause cancer or birth defects or other reproductive harm.
Reduces particles as small as 0.5 micron in size by mechanical means.
NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
4 EVERPURE
PBS-400 Water Filtration System
ENGLISH
EVERPURE
PBS-400 Water Filtration System 5
Loading...
+ 11 hidden pages