Thank you for purchasing an Everpure by Pentair commercialgrade water filtration system for your home. With your
Everpure by Pentair system, you get premium quality water
direct from your tap that’s great-tasting, healthful and
convenient for you and your family.
PRODUCT SPECIFICATIONS
• For Cold Water Use Only
• Temperature Range: 35-100°F (2-38°C)
• Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
Measure 20 inches from the base of the cabinet, and mark
the mounting location for the top of the filter head. Make sure
there is adequate space above the head to open and close
the built in shut-off valve and to avoid crimping the water
line tubing. Also, make sure your chosen location offers easy
access for future cartridge changes.
DIMENSION Width
PBS-4005 inches20 inches5 inches
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
Mounting
Height
Depth
8
10
9
2
20 inches
2• EVERPURE
®
PBS-400 Water Filtration System
BASIC INSTALLATION INSTRUCTIONS
CONTINUED
3. Mount Filter Head Under Sink
NOTE: Two sets of unions are included to connect to the 3/8-
inch head connections. If your existing braided tubing
has 1/2-inch connections, use the 1/2-inch x 3/8-inch
unions instead of the 3/8-inch x 3/8-inch unions. You
will have 2 extra fittings with either installation.
The following instructions are for a typical
installation using 1/2-inch supply lines.
A. Apply plumber tape to the small threads of one Union
Fitting and screw into the open end of the Elbow. Wrap tape
in direction of the threads to assure a tight fit and avoid
small leaks.
B. Apply plumber tape to the threads of the Elbow Fitting
and screw into the inlet (left) side of the Filter Head. Hand
tighten only.
C. Apply plumber tape to the small threads of the second
Union Fitting, and screw into the right side of the filter
head in the same manner.
D. Securely mount the filter head on the cabinet wall using
the enclosed mounting screws and washers.
4. Connect Inlet Water Supply
E. Locate and close the cold water shut-off valve under your
sink. Open cold water line of faucet to release
water pressure.
F. Unscrew and disconnect the braided tubing on top of cold
water shut-off valve.
G. Attach one end of the new braided tubing to the top of the
cold water shut-off valve.
H. Attach the other end of the new Braided Tubing to the inlet
side of the filter head (Union & Elbow Fittings).
3
A
D
C
B
4
ENGLISH
F
E
H
G
5
I
5. Attach Filtered Water To Cold Line of Faucet
I. Attach open end of existing Braided Tubing to Union Fitting
on outlet side (right) of new Filter Head. Hand tighten to
avoid damage to fittings.
6. Install And Flush Filter Cartridge
J. Lift handle of the build-in shut off (QC Valve) on the Head.
K. Hold Head firmly with one hand.
L. Align cartridge lug with label on filter Head.
M. Insert filter Cartridge—Push upwards.
N. Turn it to the right—About 1⁄4 turn—Until rotation stops.
O. Open cold water valve and check for leaks up to Inlet
Elbow Fitting.
P. Open Water Faucet (not pictured).
Q. Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridges for at least 3 minutes to
remove air and any loose carbon. At first the water
may appear cloudy due to trapped air in the filter and
tubing. If water continues to be cloudy for more that
one week, please contact Pentair Technical Support
for assistance: (800) 279-9404
R. Activate Filter Timer by pinching bubble until you feel a
change in resistance as the Filter timer “pops.” Within a few
seconds, a thin RED line will appear in the white window
showing the Timestrip® has been activated. Peel away
backing and adhere to desired location. When the white
window is completely filled with RED, it is time to replace
your product.
6
J
K
L
Label
M
Lug
Q
O
N
EVERPURE
®
PBS-400 Water Filtration System • 3
HEALTH CLAIM PERFORMANCE
WARNING:
Cysts
Lead
CLASSIFIED BY UL
This system has been tested according to NSF/ANSI 42 and
53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
ENGLISH
Substance
Standard 42—Aesthetic Effects
Chlorine2.0 mg/L ± 10%≥ 50%98%
Particulate,
Class I
particles
0.5 to <1
µm
Standard 53—Health Effects
Cyst
Lead 8.50.15 mg/L ± 10%0.010 mg/L94.1%97.2%
Lead 6.50.15 mg/L ± 10%0.010 mg/L98.9%98.9%
Influent
Challenge
Concentration
at least 10,000
particles/mL
Minimum
50,000/L
Max.
Permissible
Product Water
Concentration
Reduction
Requirements
≥ 85%99.8%
99.95%99.99%99.99%
Minimum
Reduction
NOTE: This installation must comply with all applicable state
and local regulations.
NOTE: Maximum working pressure 125 psi.
NOTE: Do no use with water that is microbiologically unsafe
or unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on waters that may contain
filterable cysts.
NOTE: Testing was performed under standard laboratory
conditions, actual performance may vary.
NOTE: This drinking water system must be maintained
according to manufacturer’s instructions, including
replacement of filter cartridges. Suggested retail
$134.99.
CALIFORNIA PROPOSITION 65 WARNING
Average
Reduction
This System has been Tested & Certified by
WQA against Std. 42 & 53 as verified and
substantiated by test data for the reduction of:
This Filter System
has been Tested
& Certified by
the WQA against
NSF/ANSI Std.
42,53, 372 & CSA
B483.1
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to
Section 116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants
Organic Contaminants
None
Rated Service Capacity 3,000 gallons Rated Service Flow: 2.2 gallons per minute
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
for cyst reduction may be used on disinfected waters that contain filterable cysts.
Certificate Number
Date Issued: December 5, 2013
Conditions of Certification
This product contains chemicals known to the
State of California to cause cancer or birth
defects or other reproductive harm.
Reduces particles as small as 0.5 micron in size by
mechanical means.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
4• EVERPURE
®
PBS-400 Water Filtration System
ENGLISH
EVERPURE
®
PBS-400 Water Filtration System • 5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.