Pentair Everpure MRS225CC User Manual

MRS-100/100CC/225/225CC
MRS Reverse Osmosis System
Configurable system that delivers reverse osmosis or blended water for multiple foodservice applications
MRS-100 System: EV9970-07 (115VAC/60Hz) EV9970-23 (230VAC/50Hz) EV9970-24 (240VAC/50Hz)
MRS-100CC System: EV9970-10 (115VAC/60Hz) EV9970-25 (230VAC/50Hz) EV9970-26 (240VAC/50Hz)
MRS-225 System: EV9970-08 (115VAC/60Hz) EV9970-27 (230VAC/50Hz) EV9970-28 (240VAC/50Hz)
MRS-225CC System: EV9970-09 (115VAC/60Hz) EV9970-29 (230VAC/50Hz) EV9970-30 (240VAC/50Hz)
Pre-filter Kit: EV9795-81
6TO-BW Cartridge: EV9607-41
7CC-BW Cartridge: EV9627-05
P5 Cartridge: EV9109-08
- System shown with optional Pre-filter kit.
BENEFITS
Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up
Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages
Sanitary cartridge replacement is simple, quick and clean–internal lter parts are never exposed to handling or contamination
Wall mount design allows exible installation
Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs–plus, scale reduction reduces energy costs
“CC” models introduce a small amount of hardness minerals back into the treated water
This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results
INSTALLATION TIPS OPERATION TIPS APPLICATION/SIZING
Choose a mounting location capable of safely supporting the full weight of the system when in operation
Deliming of existing water using equipment is
recommended
Never use saddle valve for connection
Use 3/8” (9.5 mm) minimum water line
The water inlet must supply a minimum of
0.7 gpm (2.7 lpm)
Install vertically with cartridges hanging down and allow 3” (76 mm) on all four sides of unit for cover removal and service access
The product water tubing/piping and associated
ttings connecting the RO product outlet to the
equipment being serviced should be suitable for use with high purity water
Refer to Installation, Operation & Maintenance
Change lter cartridges on a regular 6-month
preventative maintenance program
Change RO cartridges on a regular 2-year preventative maintenance program
Change cartridges when capacity is reached
Always ush the lter cartridge at time of installation and cartridge change
Proper pre-treatment is required to control RO
Cartridge (membrane) scale formation and/or fouling
- Raw water hardness in excess of 7 grains per
gallon (120 ppm) should be softened
- The raw water may contain particulates and
the use of a pre-lter is recommended
Contact EVERPURE Technical Service for pre-treatment recommendations
Mineral Reduction System for foodservice applications
Ideal for: Flash steamers, conventional steamers, cheese melters, combi-ovens and coffee/espresso machines
Daily Production Rate:
MRS-100/100CC: 100 gpd (379 lpd) nominal
0.069 gpm (0.263 lpm) nominal
MRS-225/225CC: 225 gpd (852 lpd) nominal
0.156 gpm (0.591 lpm) nominal
For use in coffee, steam, reconstitution, ice and multiple applications
Manual for cartridge ushing and RO start-up
SPECIFICATIONS
Power Cord Plug Types
NEMA 5-15P AS 3112CEE 7/7 “Schuko”
Overall Dimensions: 30" H (34" H - CC Model) x 15" W
(20.5" W with Prefilter) x 8" D 762 mm H (864 mm H - CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D [Add 3" (76 mm) on all 4 sides for cover removal and service access]
Available Voltages and Power Cord Plug Types: 115VAC/60Hz - NEMA 5-15P
230VAC/50Hz - CEE 7/7 “Schuko” 240VAC/50Hz - AS 3112
Inlet and outlet connection: 3/8" (9.5 mm) OD tube connection
Wastewater line connection: 1/4" (6.4 mm) OD tube connection
Daily Production Rate: MRS-100/100CC: 100 gpd (379 lpd) nominal
0.069 gpm (0.263 lpm) nominal
MRS Reverse Osmosis System
MRS-225/225CC: 225 gpd (852 lpd) nominal
0.156 gpm (0.591 lpm) nominal
Service Flow Rate: Dependant on water pressure in storage
tank and line size(s) to equipment
Pressure Requirements: Operating:
25 - 80 psi (1.72-5.52 bar), non-shock Maximum Static: 100 psi (6.89 bar), non-shock
Minimum Water Supply: 0.7 gpm (2.7 lpm)
Inlet Temperature: 40–100°F (4–38°C)
Inlet TDS: 1,500 ppm max recommended
Operating Weight: 35 lbs. (15.9 kg.) (not including storage tanks)
The contaminants or other substances removed or reduced by this system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
WARRANTY
MRS-100/100CC/225/225CC system (excluding replaceable elements) is covered by a limited warranty against defects in material and workmanship for a period of one year after the date of purchase.
Everpure replaceable elements (filter cartridges and water treatment cartridges) are covered by a limited warranty against defects in material and workmanship for a period of one year after date of purchase. See printed warranty for details. Everpure will provide a copy of the warranty upon request.
Everpure offers a full line of water storage tanks. See “ROmate Storage Tanks” specification sheet or contact your Everpure
sales representative for more information.
JA10