Pentair Everpure MRS-225BL User Manual

EVERPURE® MRS-225BL REVERSE OSMOSIS SYSTEMS
CONFIGURABLE SYSTEM THAT DELIVERS REVERSE OSMOSIS WATER FOR MULTIPLE FOODSERVICE APPLICATIONS
APPLICATIONS
Coffee / Tea
Ice
Steam
Reconstitution
MRS-225 BL System: EV9970-76 (115 VAC/60 Hz) EV9970-77 (230 VAC/50 Hz) EV9970-78 (240 VAC/50 Hz)
Options and Replacements: 6TO-BW Cartridge: EV9607-41 (standard) MR-225 Cartridge: EV9627-03 (standard) BW 4400 Cartridge: EV9668-24 (standard) 7TO-BW Cartridge: EV9627-04 (optional-greater capacity) Prefilter Kit: EV9795-81 (optional) P5 Cartridge: 155014-43 (optional-prefilter replacement)
FEATURES • BENEFITS
Adjustable blend valve allows custom tailoring of the dissolved mineral content in the treated water. This valve controls the amount of tap water that is mixed with the Reverse Osmosis (RO) water, creating a blend that contains a precise level of Total Dissolved Solids (TDS). The blended water then passes through a submicron carbon filter which removes taste and odor, delivering ingredient quality water
Reduces limescale buildup that can cause excessive machine downtime, increased maintenance costs, plus scale reduction reduces energy costs
Sanitary cartridge replacement is simple, quick and clean - internal filter parts are never exposed to handling or contamination
Wall mount design allows for flexible installation
INSTALLATION TIPS OPERATION TIPS
Choose a mounting location capable of safely supporting the full weight of the components when in operation
Deliming of existing water using equipment is recommended
Install vertically with cartridges hanging down and allow 3” (76 mm) on all four sides of unit for cover removal and service access
The product water tubing/piping and associated fittings connecting the RO product outlet to the equipment being serviced should be suitable for use with high purity water
Refer to Instruction & Operation Guide for cartridge flushing and RO start-up
FILTRATION & PROCESSING SOLUTIONS MRS-225BL REVERSE OSMOSIS SYSTEMS SPECIFICATION SHEET
Change filter cartridges on a regular 6-month preventative maintenance program
Change RO cartridges on a regular 2-year preventative maintenance program
Proper pretreatment is required to control RO Cartridge (membrane) scale formation and/or fouling
- Raw water hardness in excess of 7 grains per gallon (120 ppm) should be softened
- The raw water may contain particulates and the use of a prefilter is recommended
Contact Pentair Everpure Technical Service for pretreatment recommendations
SIZING
Daily Production Rate - RO Processor Only: 225 gpd (852 Lpd) nominal
0.156 gpm (0.591 Lpm) nominal
RO Processor With Blend: Capacity will vary based on tap water TDS, RO percent rejection and desired blend water TDS
An example of the adjusted capacity is shown below:
Example: 500 ppm tap water, 90% rejection, 100 ppm blend setting
Result: 225 gpd (852 Lpd) RO Processor Only + 28.1 gpd (106.37 Lpd) filtered tap water = 253.1 gpd (958 Lpd) nominal
0.176 gpm (0.665 Lpm) nominal
EVERPURE® MRS-225BL REVERSE OSMOSIS SYSTEMS
Power Cord Plug Types
EV9970-76 • EV9970-77 • EV9970-78
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
NEMA 5-15P AS 3112CEE 7/7 “Schuko”
SPECIFICATIONS
Overall Unit Dimensions
38” H x 15” W (20.5” w/prefilter) x 8” D [965 mm H x 381 mm W (521 mm W w/prefilter) x 203 mm D] [Add 3” (76 mm) on all sides for cover removal and service access] (not including storage tanks)
Inlet and Outlet Connection
3/8” (9.5 mm) OD tube connection
Wastewater Line Connection
1/4” (6.4 mm) OD tube connection
Service Flow Rate
Dependent on water pressure in storage tank and line size(s) to equipment
Available Voltages and Power Cord Types 115 VAC/60 Hz - NEMA 5-15P 230 VAC/50 Hz - CEE 7/7 “Schuko” 240 VAC/50 Hz - AS 3112
Minimum Water Supply
1.0 gpm (3.8 Lpm)
Pressure Requirements
Operating: 25 – 80 psi (1.72-5.52 bar), non-shock
Maximum Static: 100 psi (6.89 bar), non-shock
Inlet Temperature
40–100°F (4–38°C)
Inlet TDS
1,500 ppm max recommended
Shipping Weight
35 lbs. (15.9 kg.) (not including storage tanks)
WARRANTY
Everpure water treatment systems by Pentair® (excluding replaceable elements) are covered by a limited warranty against defects in material and workmanship for a period of one year after date of purchase. Everpure replaceable elements (filter cartridges and water treatment cartridges) are covered by a limited warranty against defects in material and workmanship for a period of one year after date of purchase. See printed warranty for details. Pentair will provide a copy of the warranty upon request.
Electrical (available voltages and power cord types)
115 VAC/60 Hz-NEMA 5-15P (PN: EV9970-76) 230 VAC/50 Hz - CEE 7/7 “Schuko” (PN: EV9970-77) 240 VAC/50 Hz - AS 3112 (PN: EV9970-78)
Daily Production Rate
RO Processor Only (No Blend): 225 gpd (852 Lpd) nominal
0.156 gpm (0.591 Lpm) nominal
RO Processor With Blend: Total daily production rate will vary based on tap water TDS, RO percent rejection and desired blend water TDS - Contact Pentair Everpure for assistance estimating this total
FILTRATION & PROCESSING SOLUTIONS
EVERPURE-SHURFLO WORLD HEADQUARTERS, 1040 MUIRFIELD DRIVE, HANOVER PARK, IL 60133 USA • WWW.EVERPURE.COM
800.942.1153 (US ONLY) • 630.307.3000 MAIN • 630.307.3030 FAX • CSEVERPURE@PENTAIR.COM EMAIL EVERPURE-SHURFLO AUSTRALIA, 1-21 MONASH DRIVE, DANDENONG SOUTH, VIC 3175, AUSTRALIA
011.1300 576 190 TEL • 011.61.39.562.7237 FAX • AU.EVERPURE@PENTAIR.COM EMAIL EVERPURE-SHURFLO CHINA, 21F CLOUD 9 PLAZA, NO 1118, SHANGHAI, 200052, CHINA
86.21.3211.4588 TEL • 86.21.3211.4580 FAX • CHINA.WATER@PENTAIR.COM EMAIL EVERPURE-SHURFLO INDIA, GREEN BOULEVARD, B-9/A, 7TH FLOOR - TOWER B SECTOR 62, NOIDA - 201301
91.120.419.9444 TEL • 91.120.419.9400 FAX • INDIACUSTOMER@PENTAIR.COM EMAIL EVERPURE-SHURFLO EUROPE, PENTAIR WATER BELGIUM BVBA, INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN, 30 B-2200 HERENTALS, BELGIUM
+32.(0).14.283.500 TEL • +32.(0).14.283.505 FAX • SALES@EVERPURE-EUROPE.COM EMAIL EVERPURE-SHURFLO JAPAN INC., HASHIMOTO MN BLDG. 7F, 3-25-1 HASHIMOTO, MIDORI-KU, SAGAMIHARA-SHI KANAGAWA 252-0143, JAPAN
81.(0)42.775.3011 TEL • 81.(0)42.775.3015 FAX • INFO@EVERPURE.CO.JP EMAIL EVERPURE-SHURFLO SOUTHEAST ASIA, SOUTHEAST ASIA,390 HAVELOCK ROAD, #04-01 KING’S CENTRE, SINGAPORE 169662
65.6768.5800 TEL • FAX: 65.6737.5149 FAX • CSEVERPURE@PENTAIR.COM EMAIL
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.
© 2014 Pentair Filtration Solutions, LLC.
EV9770-76 77 78 MR14
Loading...