Pentair Everpure Kleensteam II User Manual

BENEFITS
APPLICATION/SIZING
INSTALLATION TIPS
OPERATION TIPS
EV9797-22
Kleensteam II Twin System
Everpure's second generation of total water treatment system for steam applications
7CB5 Replacement Cartridge: EV9618-11
7CB5 Replacement Cartridge: EV9618-11
SS-10 Cartridge: EV9799-02
SS-10 Cartridge: EV9799-02
A total system delivering high quality filtered water with scale inhibition and deliming capabilities
New dual cartridge design provides enhanced performance for low or high flow capacity steamers
Fine filters incoming water to improve the performance, maximize energy efficiency and increase the life of steam equipment
Reduces chlorine-induced corrosion
System is simple to install, operate and maintain
Easy deliming with Everpure's ScaleKleen, which is fed directly into the boiler through the SR-X bowl without use of hazardous chemicals or special piping
Long lasting SS-10 cartridge is more effective in higher alkalinty/hardness/TDS/temperature installations.
Sophisticated Hydroblend compound prevents limescale formation in high temperature steam applications
Choose a mounting location suitable to support the full weight of the system when operating
Use minimum 1/2” inlet water line (3/4” preferred)
Connect the system to the boiler feed water line only! Do not connect to the condenser water line!
Install vertically with cartridges hanging down
Allow 2-1/2” clearance below the cartridge for easy cartridge replacement
Flush cartridges by running water through filter for five minutes at full flow
Change 7CB5 cartridge on a regular 6 month preventative maintenance program, when capacity is reached or when pressure falls below 10 psi
Change SS-10 cartridge before Hydroblend™ compound is completely used up
Service flow rate must not exceed 2.5 gpm for single cartridge systems or 5.0 for dual cartridge systems
Always flush the filter cartridge at time of installation and cartridge change
Use for periodic deliming as needed by installing the dip tube assembly in place of the SS-10 and dissolving Scale Kleen in SR-X housing. Full deliming instructions are provided with the system
For commercial steam applications
For use with foodservice steamer and combi-oven applications
The Kleensteam II Twin System is shipped with two 7CB5 cartridges and no filter head plug
KleenSteam II - Twin Cartridge
Overall Dimensions:
25.5”H x 20.5”W x 7”D
Inlet connection: 3/4” FNPT
Outlet connection: 3/4” FNPT
Service Flow Rate: Maximum 5.0 gpm (18.9 Lpm) - twin cartridges
Pressure Requirements: 10 - 125 psi (0.7 – 8.6 bar), non-shock
Maximum water temperature at inlet: 100°F (38°C)
Kleensteam II Twin System
Alkalinity range: 2 to 12 grains per gallon
No electrical connection required
Shipping Weight: 28 lbs.
Operating Weight: 35 lbs.
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
Everpure water treatment systems (excluding replaceable elements) are covered by a limited warranty against defects in material and workmanship for a period of five years after date of purchase. Everpure replaceable elements (filter cartridges and water treatment cartridges) are covered by a limited warranty against defects in material and workmanship for a period of one year after date of purchase. See printed warranty for details. Everpure will provide a copy of the warranty upon request.
ScaleStick is NSF Certified under NSF/ANSI Standard 42 for materials