Pentair Pro Elite Professional Series, Pro Elite268-762-100-1044 Demand, Pro Elite 268-762-150-1248 Demand, Pro Elite 268-762-200-1248 Demand Operation Manual

PRO ELITE PROFESSIONAL SERIES PRO ELITE DEMAND WATER TREATMENT SYSTEM
OPERATION MANUAL
Table of Contents
Performance Data Sheet ......................................................................................................................................3
How To Use This Manual .......................................................................................................................................4
Safety Information ...............................................................................................................................................4
Valve Layout ......................................................................................................................................................... 5
Demand Control Layout ........................................................................................................................................5
System Specications 762 ...................................................................................................................................5
Location Selection ............................................................................................................................................... 6
Outdoor Locations ...............................................................................................................................................6
System Features .................................................................................................................................................. 7
Equipment Installation .........................................................................................................................................8
Water Line and Bypass Connections ................................................................................................................... 11
Drain Line Connection .........................................................................................................................................12
Regenerant Line Connections .............................................................................................................................12
Overow Line Connection ...................................................................................................................................13
Electrical Connection ..........................................................................................................................................13
System Operation............................................................................................................................................... 14
Cycle Water Flows .............................................................................................................................................. 14
Camshaft Cycle Positions ....................................................................................................................................15
Valve Disc Location/Function ..............................................................................................................................15
Disinfection of Water Conditioning Systems........................................................................................................16
Displays, Icons and Cursors .................................................................................................................................17
Button Functions ................................................................................................................................................17
Programming Overview .......................................................................................................................................18
Demand Control Operation ..................................................................................................................................18
Level I Programming ...........................................................................................................................................18
Level l Programming - Demand Conditioner .......................................................................................................19
Level II Programming – P Values ..........................................................................................................................21
Level I Programming – P Values ..........................................................................................................................20
Programming the Lockout Feature ....................................................................................................................22
Level lll Cycle Programming – C Values ...............................................................................................................22
Placing 268 Water Conditioning System Into Operation (Fill Brine Tank Last) .....................................................24
Rell First Operation .......................................................................................................................................... 25
Manual Regeneration Options ............................................................................................................................26
Pro Elite Valve - Exploded View and Parts List .................................................................................................... 27
Conditioner Tank and Regenerant Tank Assembly - Exploded View and Parts List .............................................29
Brine Well Assembly - Exploded View and Parts List ...........................................................................................31
CH15675 ..............................................................................................................................................................31
Troubleshooting .................................................................................................................................................32
2 • PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual
Performance Data Sheet
Pro Elite Demand Water Softener System Performance Data Sheet
Model Pro Elite
268-762-100-1044
Demand
Pro Elite
268-762-150-1248
Demand
Pro Elite
268-762-200-1248
Demand
Rated Service Flow (gpm) 12.0 13.0 14.4
Pressure Drop at Rated
Service Flow Rate (psi)
Rated Capacity
(grains @ lb of salt)
Rated Eciency (grains/lb Salt @ lb of salt)
Maximum FLow Rate
During Regeneration (gpm)
10% Cross Linked Ion Exchange Resin (cu ft)
4,582 grains/lb @ 3.3 lbs 5,201 grains/lb @ 4.95 lbs. 5,470 grains/lb @ 6.6 lbs
11 12 15
15,122 @ 3.3 lbs 21,716 @ 9.0 lbs
27,641 @ 15.0 lbs
25,746 @ 4.95 lbs
36,972 @ 13.5 lbs
47,059 @ 22.5 lbs
5.5 5.5 5.5
1.0 1.5 2.0
36,102 @ 6.6 lbs
51,844 @ 18.0 lbs
65,988 @ 30.0 lbs
Tank Size 10" x 44" 12" x 48" 12" x 48"
Backwash - GPM 2.7 3.9 3.9
Rapid Rinse/Purge - GPM 5.5 5.5 5.5
Operating Pressure: 20-125 psi or 1.4-8.8 kg/cm2, Operating Temperature: 34-100°F or 1.1-43.3°C Acceptable Salt Type: Sodium Chloride - Pellet salt
All Systems above tested at 35 psi ±5 psi, pH of 7.5 ±0.5, Capacity Testing Flow Rate = 50% of the rated service ow rate for the
various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specic performance claims as veried and substantiated by test data. The rated salt eciencies above were
also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above.
An eciency rated water softener is a demand initiated regeneration (DIR) softener which also complies with specic performance specications intended to minimize the amount of regenerant brine and water used in its operation. Eciency rated water softeners shall have a rated salt eciency of not less that 3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The rated eciency of the water softener, the salt dosage at that eciency, the capacity at that salt dosage and that of the eciency is only valid at the stated salt dosage. Eciency is measured by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible eciency the system can achieve. Operational eciency is the actual eciency achieved after the system has been installed. It is typically less than the eciency due to individual application factors including water hardness, water
usage, and other contaminants that reduce the water softener’s capacity. These systems are not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Refer to the system Installation and Service Manuals for set-up and programming instructions.
Contact your local dealer for parts and service. See your owner’s manual for warranty information
Tested and Certied by
WQA against NSF/ANSI
Std. 44 & 372 for “lead free”
compliance & CSA B483.1.
PENTAIR Residential Filtration, LLC
13845 Bishops Drive Suite 200
Brookeld, WI 53005
PHONE: (262) 238-4400
2/01/19
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 3
How To Use This Manual
This installation manual is designed to guide the installer through the process of installing and starting water conditioning systems featuring Pro Elite equipment.
This manual is a reference and will not include every system installation situation. The person installing this equipment should have:
• Training in the Pro Elite Demand systems.
• Knowledge of water conditioning and how to determine proper control settings.
Adequate plumbing skills and qualications per local and state laws, codes, and ordinances.
Icons That Appear In This Manual
• Do not use petroleum-based lubricants such as petroleum jelly, oils, or hydrocarbon-based lubricants. Use only 100% silicone lubricants.
• Use only the power transformer supplied with this water conditioning system.
• All electrical connections must be completed according to local codes.
• The power outlet must be grounded.
Install an appropriate grounding strap across the inlet and outlet piping of the water conditioning system to ensure that a proper
ground is maintained.
WARNING: Dry location use only, unless used with a Listed Class 2 Power Supply suitable for outdoor use.
WARNING: Failure to follow this instruction can result in personal injury or damage to the equipment.
Note: Helpful hint to simplify procedure.
Safety Information
• Observe all warnings that appear in this manual.
• Please review the entire Installation and Operation Manual before installing the water conditioning system.
• As with all plumbing projects, it is recommended that a trained professional water treatment dealer install the water conditioning system. Please follow all local plumbing codes for installing this water conditioning system.
WARNING: Excessive Weight Hazard. Use two or more people to move and
• System is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
• This water conditioning system is to be used only for potable water.
• Inspect the water conditioning system for carrier shortage or shipping damage before beginning installation.
Use only lead-free solder and ux, as required by federal and state codes, when installing soldered copper plumbing.
• Use caution when installing soldered metal piping near the water conditioning system. Heat can adversely affect the plastic control valve and bypass valve.
• All plastic connections should be hand tightened. plumber tape may be used on connections that do not use an O-ring seal. Do not use pipe dope type sealants on the valve body. Do not use pliers or pipe wrenches.
install the conditioner. Failure to do so can result in injury (including back injury).
• To disconnect power, unplug the AC adapter from its power source.
• Observe drain line requirements. The drain line must be a minimum of 1/2-inch diameter. Use 3/4-inch pipe if the
backwash ow rate is greater than 5 gpm (19 Lpm) or the
pipe length is greater than 20 feet (6 m).
• Do not support the weight of the system on the control
valve ttings, plumbing, or the bypass.
• Do not allow this water conditioning system to freeze. Damage from freezing will void this water conditioning system’s warranty.
• Operating ambient temperature: 34° to 120°F
(1° to 49°C).
Operating water temperature: 35° to 100°F (1.7° to 38°C).
Operating water pressure range : 20 to 125 psi (1.38 to 8.62 bar). In Canada the acceptable operating water pressure range is 20 to 100 psi
(1.38 to 6.89 bar).
WARNING: The valve and tank components of this Pro Elite unit have been assembled and tightened to the
proper factory torque specications.
Over tightening may result in improper valve, probe and tank alignment and may
damage the tank O-ring (PN1010154).
• Keep the media tank in the upright position. Do not turn upside down or drop. Turning the tank upside down or laying the tank on its side can cause media to enter the valve.
• Ensure that all wiring and plumbing connections on the mineral and brine tanks are installed correctly.
• Use only regenerants designed for water conditioning. Do not use ice melting salt, block salt or rock salt.
4 • PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual
Valve Layout
Valve Discs
Demand Control
Rell Controller
Regenerant Tube Connection
Demand Control Layout
SU MO TU WE TH FR SA DAYS
Time/Day
Regeneration Time/Day
Salt Amount
Capacity
Check Salt
One Piece Valve Disc Spring
Injector and Cap
PM
Outlet
Drain
Motor
Inlet
Optical Sensor
Camshaft
Injector Screen Filter
Backwash Drain Control
AC Adapter Connection
(12 Volt Input)
Motor & Optical
Sensor Connection
Demand Series
Turbine Meter
Input
Front Back
System Specications 762
Model Number 268-762-100-1044 268-762-150-1248 268-762-200-1248
Recharge Style Demand Demand Demand
Media Tank Size 10" x 44" (25 x 112 cm) 12" x 48" (30.5 x 122 cm) 12" x 48" (30.5 x 122 cm)
Resin Volume 1 ft3 (0.03 m3) 1.5 ft3 (0.04 m3) 2 ft3 (0.056 m3)
Recharge (Salt) Tank Size 19" x 36" (48.3 x 91.5 cm) 19" x 36" (48.3 x 91.5 cm) 19" x 36" (48.3 x 91.5 cm)
Salt Storage 240 lbs (109 kg) 240 lbs (109 kg) 240 lbs (109 kg)
Drain Water Rate 2.7 gpm (10.2 L/m) 3.9 gpm (14.7 L/m) 3.9 gpm (14.7 L/m)
Service Connection Size 1" NPT 1" NPT 1" NPT
Drain Connection Size 3/4" NPT 3/4" NPT 3/4" NPT
Recharge (Brine) Connection
Size
Installation Space Requirements
3/8" NPT 3/8" NPT 3/8" NPT
21" x 42" x 72"
(53.3 x 106.6 x 182.8 cm)
21" x 42" x 72"
(53.3 x 106.6 x 182.8 cm)
21" x 42" x 72"
(53.3 x 106.6 x 182.8 cm)
Shipping Weight 140 lbs (63.5 kg) 165 lbs (74.8 kg) 200 lbs (90.7 kg)
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 5
Location Selection
Location of a water conditioning system is important. The following conditions are required:
Level platform or oor.
Note: The Pro Elite System can be provided with optional leveling feet that may be used on the two
tanks. Order part number 4000409.
• Room to access equipment for maintenance and adding regenerant (salt) to tank.
• Ambient temperatures over 34°F
(1°C and below 120°F (49°C).
Water pressure below 125 psi (8.62 bar) and above 20 psi (1.38 bar).
• In Canada the water pressure must
be below 100 psi (6.89 bar).
• Constant electrical supply to operate the control.
• Total minimum pipe run to water heater of ten feet (three meters) to prevent backup of hot water into system.
• Local drain for discharge as close as possible.
• Water line connections with shutoff or bypass valves.
• Must meet any local and state codes for site of installation.
• Valve is designed for minor plumbing misalignments. Do not support weight of system on the plumbing.
• Be sure all soldered pipes are fully cooled before attaching plastic valve to the plumbing.
Outdoor Locations
It is recommended that the Pro Elite conditioner be installed in a protected environment.
When installing the water conditioning system outdoors, several items must be considered:
• Moisture – The valve and control are rated for NEMA 3 locations. Falling water should not affect performance. The system is not designed to withstand extreme humidity or water spray from below. Examples are: constant heavy mist, near corrosive environment, or upwards spray from sprinkler.
• Direct Sunlight – The materials used will fade or discolor over time in direct sunlight. The integrity of the materials will not degrade to cause system failures.
• Temperature – Extreme hot or cold temperatures will cause damage to the valve or control. Freezing temperatures will freeze the water in the valve. This will cause physical damage to the internal parts as well as the plumbing and conditioning resin. High temperatures will affect the control. The display may become unreadable but the control should continue to function. When the temperature returns to normal operating limits, the display will re­appear. A protective cover should assist with high temperature applications.
• Insects – The control and valve have been designed to keep all but the smallest insects out of the critical areas. Any holes in the top plate can be covered with duct tape. The top cover should be installed securely in place.
WARNING: Dry location use only, unless used with a Listed Class 2 Power Supply
6 • PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual
suitable for outdoor use.
System Features
Resin Tank
2
8
Brine Tank
1
1
2
7
5
7
13
11
5
3
3
10
6
4
12
4
9
6
1 Cover 8 Cover
2 Cap, Cover 9 Foot, Leveling
3 Jacket,Resin Tank 10 Latch Mechanism
4 Base 11 Tank Collar
5 268 Logix PE Valve
w/762 Control
6 Resin Tank 13 Upper Basket
7 Shield
12 Riser Tube
1 Cover 5 Brine Tube Assembly
2 Collar, Tank 6 Foot, Leveling
3 Tank, Brine 7 Latch Mechanism
4 Base, Tank
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 7
Equipment Installation
60.7 (1541.6)
17.6 (447)
55 (1398.1)
Dimensions
16.8 (427.1)
20.5 (521.1)
35.1 (890.4)
(503.8)
19.8
36.9 (938.1)
5.0 (127)
2.5 (63.5)
53.4 (1356.6)
32.2 (817.5)
28.2 (715.9)
8 • PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual
Typical System Layout
Bath TubLavatoryToilet Kitchen
Outside
Faucet
Outside
Faucet
Hot Water
Outlet
Water
Heater
Pump
Laundry Tubs
or
Meter
Floor Drain
Figure 1 Standard Basement Before Installation. Cold water lines shown.
Bath TubLavatoryToilet Kitchen
Hot Water
Outlet
Grounding
Strap
Outside
Faucet
Outside
Faucet
Soft Water
Hard Water
Pump
or
Meter
Water Heater
Bypass
Drain Line
Softener
Laundry Tubs
Brine Tank Overow Drain
Figure 2 Softened Water Flow Diagram.
Floor Drain
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 9
Inspection
The Pro Elite system is shipped with several parts unassembled. When parts are removed from the packing, they should be inspected for damage. If any parts are damaged or missing, contact your supplier.
WARNING: When handling the media tank do not turn it upside down or drop
When the carton is rst opened, the softener will be
standing upright. The salt tank will be turned over and covering the softener (Figure 3).
Salt Tank Cover
Salt Tank Base
on its side.
Salt Tank Collar
To Assemble the Media Tank:
1. If the oor under the media tank is uneven, the leveling feet may be installed. Slowly lay the tank on its side. Press or tap the feet into the pockets.
WARNING: The media tank contains loose particles that will shift. If the tank is turned upside down or laid back quickly, the particles may enter the valve. If this happens, the valve may need to be disassembled and cleaned.
2. Stand the tank up and in position. Level as needed.
3. Remove cover by pressing in on the latch and lifting cover (Figure 4). When the cover is removed, the valve is visible. Remove the power adapter. They should be secured to the tank collar near the inlet/outlet connections.
Lift
Salt Tank
(Upside Down)
Brine Tube
Assembly
Media Tank
(Softener)
Media Tank Base
Figure 3
To assemble the system, remove the salt tank components (cover, collar, base and brine tube assembly) from the shipping container. The media tank can now be removed. Locate the miscellaneous parts bag.
To assemble the Salt Tank:
1. If the oor under the salt tank is uneven, the leveling feet may be installed. Lay the empty salt tank on its side. Press or tap the feet into the pockets.
2. Stand the salt tank up and in position. Level as needed. The tank has two ports that will be connected. One to a drain and one to the valve.
3. Place the brine tube in position inside the pocket at
the bottom of the tank. Install the overow tting.
4. Place the tank collar over the top of the brine tube. Position the collar and push it down into the tank. Lay the cover aside for now.
10 • PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual
Press in
Figure 4
Water Line and Bypass Connections
A bypass valve system should be installed on all
water conditioning systems. A model 1265 bypass is
included with this system. The bypass valve isolates the conditioner from the water system and provides unconditioned water to service during routine
maintenance and servicing procedures. See Figure 5 Model 1265 Bypass (Included) and Figure 6 Typical Three Valve Bypass Conguration
(Not provided by manufacturer).
Note: Before turning on the water to the valve, rotate the two handles on the bypass valve 2-3 times. This will help seat the O-rings and prevent leaking.
Normal Operation
In
B
Y
P
A
S
S
Out
B
Y
P
A
S
S
In
A
P
S
S
In Bypass
Y
B
Out
A
S
S
P
Y
B
WARNING: Do not use tools to tighten
plastic ttings. Over time, stress may
break the connections. Hand tighten the nuts.
WARNING: Do not use petroleum grease on gaskets when connecting bypass plumbing. Use only 100% silicone grease products when installing any Pro Elite brand valve. Non-silicone grease may cause plastic components to fail over time.
WARNING: The inlet water must be connected to the inlet port of the valve. When replacing non-Pro Elite valves, it is possible that the inlet and outlet plumbing is installed in a reversed position. Ensure that the plumbing is not installed in the opposite order. Tank media may be pushed into the valve.
Water Conditioner Water Conditioner
Figure 5 Model 1265 Bypass (Included)
Normal Operation
Water Conditioner Water Conditioner
In Bypass
Figure 6 Typical Three Valve Bypass Conguration
(Not provided by manufacturer)
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 11
Loading...
+ 25 hidden pages