PBS400 WATER FILTRATION SYSTEM
SISTEMA DE FILTRACIÓN DE AGUA PBS400
PBS400 SYSTÈME DE FILTRAGE D’EAU
pentair.com
Thank you for purchasing an Everpure by Pentair
1
2
6
5
873
4
9
commercial grade water filtration system for your home.
With your Everpure by Pentair system, you get premium
quality water direct from your tap that’s great-tasting,
healthful and convenient for you and your family.
PRODUCT SPECIFICATIONS
• For Cold Water Use Only
• Temperature Range: 35-100°F (2-38°C)
• Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
Measure 20 inches from the base of the cabinet, and mark
the mounting location for the top of the filter head. Make sure
there is adequate space above the head to open and close
the built in shut-off valve and to avoid crimping the water
line tubing. Also, make sure your chosen location offers easy
access for future filter cartridge changes.
DIMENSION Width
PBS-4005 inches20 inches5 inches
NOTE: The filter head and filter cartridge must be mounted
2 • EVERPURE® PBS-400 Water Filtration System
in the vertical position, with the cartridge hanging
down.
Mounting
Height
Depth
BASIC INSTALLATION INSTRUCTIONS
A
B
C
D
CONTINUED
3
3. Installing Union Connections
NOTE: Two union connections and a stainless steel braided
A. Apply plumber tape to the 3/8” NPT threads on both union
B. Screw elbow fitting into the inlet port of the filter head.
C. Install union fittings onto filter head and elbow.
D. Securely mount the filter head on the cabinet wall using the
4. Connect Inlet Water Supply
E. Locate and close the cold water shut-off valve under your
F. Unscrew and disconnect the braided tubing from the cold
G. Attach one end of the supplied braided tubing to the top of
H. Attach the other end of the supplied braided tubing to the
5. Connect System to Faucet
I. Attach open end of existing Braided Tubing to Union Fitting
hose are included to allow installation to a 3/8” cold
water supply line. A 90 degree plastic elbow fitting is
included to prevent kinking of supply hose.
fittings and elbow fitting. Wrap tape in direction of the
threads to assure a tight fit and avoid small leaks.
enclosed mounting screws and washers.
sink. Open cold water line of faucet to release
water pressure.
water supply line.
the cold water supply line.
inlet connection of the filter head.
on outlet side (right) of new system. Hand tighten to avoid
damage to fittings.
INLETOUTLET
ENGLISH
4
F
E
H
G
5
I
6. Install And Flush Filter Cartridge
J. Lift handle of the build-in shut off (QC Valve) on the Filter
Head.
K. Hold Head firmly with one hand.
L. Align filter cartridge lug with label on filter Head.
M. Insert filter cartridge—Push upwards.
N. Turn it to the right—About 1⁄4 turn—Until rotation stops.
O. Open cold water valve and check for leaks up to Inlet
Elbow Fitting.
P. Open Water Faucet (not pictured).
Q. Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridge for at least 3 minutes to
remove air and any loose carbon. At first the water
may appear cloudy due to trapped air in the filter and
tubing. If water continues to be cloudy for more than
one week, please contact Pentair Technical Support for
assistance: (800) 279-9404
R. Activate Filter Timer by pinching bubble until you feel
a change in resistance as the Filter timer “pops.”
Within a few seconds, a thin RED line will appear in
the white window showing the Timestrip(R) has been
activated. Peel away backing and adhere to desired
location. When the white window is completely filled
with RED, it is time to replace your product.
6
J
K
L
Label
M
Lug
Q
O
N
EVERPURE PBS-400 Water Filtration System • 3
PERFORMANCE DATA PBS400
WARNING:
This system has been tested according to NSF/ANSI 42 and
53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
Influent
ENGLISH
Substance
Standard 42—Aesthetic Effects
Chlorine2.0 mg/L ± 10%≥ 50%>97.6%
Particulate,
Class I
particles
0.5 to <1
µm
Standard 53—Health Effects
Cysts*
Lead 8.50.15 mg/L ± 10%0.010 mg/L94.1%>98.5%
Lead 6.50.15 mg/L ± 10%0.010 mg/L98.9%>99.7%
*NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
Challenge
Concentration
at least 10,000
particles/mL
Minimum
50,000/L
NOTE: This installation must comply with all applicable state
and local regulations.
NOTE: Maximum working pressure 125 psi.
NOTE: Do no use with water that is microbiologically unsafe
or unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on waters that may contain
filterable cysts.
NOTE: Testing was performed under standard laboratory
conditions, actual performance may vary.
NOTE: This drinking water system must be maintained
according to manufacturer’s instructions, including
replacement of filter cartridges.
NOTE: An absorption product used will not be regenerated
for reuse. If an absorption product is affected by
chlorine, the water supply should be treated to
remove chlorine before introducing the filter.
Max.
Permissible
Product Water
Concentration
Reduction
Requirements
≥ 85%>99.9%
99.95%99.99%>99.99%
Minimum
Reduction
Average
Reduction
C US
The PBS-400 is tested and Certified by NSF
International against CSA B483.1 and NSF/
ANSI standard 42 and 53 for the claims
specified on the performance data sheet.
CALIFORNIA PROPOSITION 65 WARNING
This product contains chemicals known to the
State of California to cause cancer or birth
defects or other reproductive harm.
EPA Est. No. 002623-IL-002
4 • EVERPURE PBS-400 Water Filtration System