Pella insynctive bridge Product Manual

PELLA® INSYNCTIVE™ PRODUCT GUIDE
BRIDGE
BRIDGE wirelessly connects your Pella Insynctive products to STATUS INDICATOR or a compatible
security or home automation system.
WHAT’S NEEDED:
• ONE OR MORE PELLA INSYNCTIVE PRODUCTS (sold separately).
PELLA INSYNCTIVE STATUS INDICATOR (optional — sold separately): Indicates status of Pella Insynctive SENSORS. Or you can use a compatible security or home automation system.
PELLA® INSYNCTIVE™ BRIDGE PRODUCT GUIDE | 1
TABLE OF CONTENTS
3
4
5 6
9
General and Safety Information
n
Registering Products
n
Need Help?
n
Home Automation or Security System
n
Warnings
Product Overview
n
Specifications
Detailed Instructions
Factory Reset Bridge
Additional Instructions
n
Volume and Chime Settings
11
14
n
Changing Chime Settings
n
Chime Indication Table
n
Installation Recommendations
n
Product Manufacturer’s Code
n
Care and Maintenance
n
Replacing Backup Battery
Special Features
n
Troubleshooting
Sensor Test Mode
n
Z-Wave Test Mode
n
Faults
15
FCC Compliance and Industry Canada/Limited Warranty
PELLA® INSYNCTIVE™ BRIDGE PRODUCT GUIDE | 2
GENERAL AND SAFETY
WARNING
INFORMATION
REGISTERING PRODUCTS
Visit Insynctive.Pella.com/Registration for instant access to instructions, warranties and how-to videos.
NEED HELP?
Find troubleshooting information and videos at Insynctive.Pella.com/Support or call 855-473-5524.
HAVE A HOME AUTOMATION OR SECURITY SYSTEM?
®
Visit Insynctive.Pella.com/HomeAutomation for instructions on how to sync Pella
Failure to adhere to the warnings below may result in death, serious injury and/or loss of valuables.
• Pella Insynctive BRIDGE is not 100% reliable for a variety of reasons. For example, BRIDGE:
— communicates data wirelessly, and wireless data is susceptible to interference or failure.
Insynctive™ products.
— requires proper installation.
— requires a battery with an adequate charge in the event of a power outage.
— may be damaged after installation.
Therefore, Pella Insynctive products should not be relied upon in situations where life, safety, and/or protection of valuables are solely dependent on their function. Test each product at least once per year to help ensure proper operation.
• BRIDGE may be connected to a non-Pella product such as a compatible security or home automation system. All systems are subject to compromise or failure to warn for a variety of reasons. Review and comply with the information for the system that is connected with BRIDGE.
• Pella Insynctive products are not a substitute for careful adult supervision of children.
• Keep battery and other small parts out of reach of children. If battery or any parts are swallowed, immediately seek medical help.
• Batteries carry the risk of fire, explosion and burns. Do not recharge, disassemble or incinerate.
PELLA® INSYNCTIVE™ BRIDGE PRODUCT GUIDE | 3
PRODUCT OVERVIEW
TEST
BRIDGE is the wireless communication hub that connects your Pella® Insynctive™ products to STATUS INDICATOR or a compatible security or home automation system.
BRIDGE can be operated without home automation (stand-alone mode) or can be used with home automation. For more information on compatible home automation systems, see Insynctive.Pella.com/HomeAutomation.
WITHOUT HOME AUTOMATION (Stand-Alone Mode):
In stand-alone mode, BRIDGE will beep twice (if chime is enabled) when Pella Insynctive SENSORS within the system change to opened or unlocked status. BRIDGE will provide current SENSOR status to STATUS INDICATOR when STATUS INDICATOR senses motion within its field of range.
WITH HOME AUTOMATION:
Connecting BRIDGE to a home automation system can provide additional functionality and greater control within your home. If using a home automation system with Z-Wave, BRIDGE must be located in the same room — in close proximity to the Z-Wave gateway (within 50 feet).
BUTTON
SYNC
BUTTON
LIGHT
SPECIFICATIONS:
Frequency: 433.92 MHz (Insynctive), 908.42 MHz (Z-Wave)
Operating Temperature: 32° – 120°F (0° – 49°C)
Operating Humidity: 5% – 95% RH noncondensing
Optional Battery: Motorola BP6X 3.7V lithium ion polymer rechargeable battery
Typical Battery Life: 4 – 6 hours (may vary by use)
Enrollment Capacity: 128 Dev ices
Indoor Use Only
PELLA® INSYNCTIVE™ BRIDGE PRODUCT GUIDE | 4
DETAILED INSTRUCTIONS
See Insynctive.Pella.com/Support for how-to videos.
WITHOUT HOME AUTOMATION (STAND-ALONE MODE):
1. Get Started
TEST
BUTTON
Plug BRIDGE into an electrical outlet (light will turn green and then flash blue).
SYNC
BUTTON
LIGHT
2. Sync Your Pella® Insynctive™ Smart Products
Press and hold the sync button until the light begins flashing orange.
BRIDGE is in sync mode while the orange light is flashing. BRIDGE will remain in sync mode for 2 minutes. BRIDGE will then beep, and orange light will turn off to indicate BRIDGE has exited sync mode.
BRIDGE is now ready to sync to Insynctive devices.
Refer to the Quick Start Guide included with your Insynctive product(s) for instructions on how to sync with BRIDGE.
WITH HOME AUTOMATION:
Visit Insynctive.Pella.com/HomeAutomation for a list of
compatible home automation systems. For installations via Ethernet cable, skip Z-Wave sync process below.
Z-WAVE SYNC PROCESS:
TEST
BUTTON
SYNC
BUTTON
LIGHT
1. Get Started
Plug BRIDGE into an electrical outlet (light will turn green and then flash blue).
BRIDGE is in Z-Wave sync mode while the light is flashing blue. BRIDGE will remain in Z-Wave sync mode for 2 minutes. BRIDGE will then beep, and blue light will turn off to indicate BRIDGE has exited sync mode.
2. Sync BRIDGE to Z-Wave Home Automation System
While BRIDGE light is flashing blue, initiate the sync or learn process for your Z-Wave home automation system.
PELLA® INSYNCTIVE™ BRIDGE PRODUCT GUIDE | 5