Pelco KBD9000 User Manual

®
KBD9000
Transmitter/
Controller
Installation/
Operation Manual
C551M (4/98)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
CONTENTS
Section Page
1.0 GENERAL .................................................................................................. 3
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3
1.2 REGULATORY NOTICES ..................................................................4
1.3 UNPACKING INSTRUCTIONS .......................................................... 4
2.0 DESCRIPTION .......................................................................................... 5
2.1 MODELS ............................................................................................6
2.2 CERTIFICATIONS .............................................................................6
3.0 INSTALLATION .......................................................................................... 7
3.1 POWER ............................................................................................. 7
3.2 VIDEO INPUT ....................................................................................7
3.3 VIDEO OUTPUT ................................................................................7
3.4 SYSTEM CONFIGURATIONS ...........................................................7
4.0 OPERATION .............................................................................................11
4.1 FUNCTIONAL CIRCUIT DESCRIPTION .......................................... 11
4.2 KBD9000 CONTROLS ...................................................................... 12
5.0 TROUBLESHOOTING .............................................................................. 13
6.0 MAINTENANCE ........................................................................................14
7.0 SPECIFICATIONS .................................................................................... 15
8.0 WARRANTY AND RETURN INFORMATION ........................................... 16
LIST OF ILLUSTRATIONS
Figure Page
1 Basic KBD9000 Configuration ........................................................... 8
2 KBD9000 Configuration with Manual Video Switcher
and Multiple Cameras ........................................................................8
3 Basic KBD9000 Configuration Interconnect Diagram ........................ 9
4 KBD9000 Configuration with Multiple Transmitters and Receivers ... 10
5 KBD9000 Control Buttons .................................................................12
6 KBD9000 Dimension Drawing .......................................................... 15
LIST OF TABLES
Table Page
A Video Coaxial Cable Requirements ...................................................7
REVISION HISTORY
Manual # Date Comments
C551M 1/98 Original version.
4/98 Added Certifications. Deleted Figure 4.
2 Pelco Manual C551M (4/98)

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C551M (4/98) 3

1.2 REGULATORY NOTICES

NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are de­signed to provide reasonable protection against harmful interference in a residen­tial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter­mined by turning the equipment off and on, the user is encouraged to try and cor­rect the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

1.3 UNPACKING INSTRUCTIONS

Unpack and inspect all parts carefully.
The following items are supplied:
1 KBD9000 Transmitter/Controller 1 Installation/Operation Manual (C551M) 1 12 VAC Wall Mount Transformer
Be sure to save the shipping carton, boxes and inserts. They are the safest material in which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its box and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement. (International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY AND RETURN section of this manual for instructions.
4 Pelco Manual C551M (4/98)

2.0 DESCRIPTION

The KBD9000 Transmitter/Controller is a desk top unit that provides up to 16 re­mote control functions. It operates without the need for control cables other than for a dedicated video cable for the normal transmission of a remote camera signal to the local monitoring and control position. Coaxitron® control lends itself to applica­tions where short-to-medium distances are involved and where equalization of cable losses is not required.
Check your receiver/driver manual for active functions.
Typically, control functions are:
1. Pan Left
2. Pan Right
3. Tilt Up
4. Tilt Down
5. Zoom In
6. Zoom Out
7. Focus Near
8. Focus Far
9. Iris Open
10. Iris Close
11. Camera Power On/Off
12. Auto/Manual Scan
13. AUX 1
14. AUX 2
15. AUX 3
16. AUX 4
Functions 1 through 10, 15 and 16 are momentary; that is, they are only actuated while the associated control switch on the KBD9000 is operated. Functions 11, 12, 13 and 14 are latching; that is, camera power, auto scan, and auto/ manual iris are latching functions and remain on until turned off. The latching iris function is not dedicated, and with proper interfacing, it can be used for some other latching func­tion. Alternately, AUX 1, 2, 3 and 4 may be used as momentary functions to control such things as lights or gates with proper external interfacing. Up to ten functions can be operated simultaneously. Functions 11 through 16 must be used individu­ally; although any one of these functions may be used simultaneously with func­tions 1 through 10.
KBD9000 is an improved version of the original Coaxitron® transmitter/controller. Improvements include the following features:
1. When used with a Pelco CX900TLC Test Local Control Plug-in Module, pro­vides troubleshooting capability for both the receiver and the KBD9000.
2. Pan/tilt, zoom, and camera power control are included on the main receiver board, which eliminates malfunctions due to incorrect wiring or broken wires.
Pelco Manual C551M (4/98) 5
Loading...
+ 11 hidden pages