Pelco FTV10D11, FTV10D1M1ST, FTV10D1S1FC, FRV10D1M1, FRV10D1S1ST operations manual

...
INSTALLATION AND OPERATION MANUAL
FTV/FRV10D1(M,S)1(ST,FC) Series
10-BIT DIGITALLY ENCODED VIDEO WITH “UP-THE-COAX” EXTENDED DISTANCE OR BI-DIRECTIONAL DATA (RS232, RS422 RS485 2/4W)
The FTV/FRV10D1(M,S)1(ST,FC) series transmits 10 bit digital video and
NTSC, PAL and SECAM CCTV camera systems. The data supports RS232,
RS422 and RS485 (2W & 4W) at data rates up to 115 Kbps (NRZ). The FTV/
FRV10D1(M,S)1(ST,FC) series also supports “Up-the-Coax” control signals
for Pelco Coaxitron. The product is “Plug-and-Play” with no electrical or optical
adjustments.
The FTV/FRV10D1(M,S)1(ST,FC) series allows the user to choose
bi-directional data or up-the-coax data through a switch on the unit, as
described in Figure 5 on Page 4.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining
equipment operating status. Figure 6 on Page 4 describes the LED indicators
for each light on the unit.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 6 for installation instructions.
See Figures 1 – 7 for complete installation details.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C5633M-A / REV 07-24-14
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C5633M-A / REV 07-24-14
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOIN
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOIN
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOOUT
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
INSTALLATION AND OPERATION MANUAL FTV/FRV10D1(M,S)1(ST,FC)
FIGURE 1 – FTV/FRV10D1(M,S)1(ST,FC) SERIES TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK WITH WHITE STRIPES
BLACK Power Supply: Surface Mount: 8–15 VDC @ 2W Rack Mount: From Rack NOTE: Remove Electrical Connector for Rack Mount Units Above wiring assumes use of Pelco FEXTPS power supply. When using non-Pelco power supplies, confirm polarity before connecting.
FIGURE 2 – TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FTV10D1S1ST
VIDEO
TRANSMITTER
+ 2 WAY DATA / UP the COAX
VIDEOIN
LINK
VIDEO
DATA IN
DATAOUT
POWER
12
ON
DOUT
DIN GND DIN+
DIN­DOUT+ DOUT-
GND
+Vin
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
IN/OUT
OPTICAL
DATA
232485422
A B
PWR
FIGURE 3 – RECEIVER
FRV10D1S1ST
VIDEO
RECEIVER
+ 2 WAY DATA / UP the COAX
LINK
VIDEO
DATA IN
DATAOUT
ON
12
POWER
VIDEOOUT
DOUT
DIN GND DIN+
DIN­DOUT+ DOUT-
GND
+Vin
IN/OUT
OPTICAL
DATA
232485422
A B
PWR
C5633M-A / REV 07-24-14