Pelco FTV10D11, FTV10D1M1ST, FTV10D1S1FC, FRV10D1M1, FRV10D1S1ST operations manual

...
INSTALLATION AND OPERATION MANUAL
FTV/FRV10D1(M,S)1(ST,FC) Series
10-BIT DIGITALLY ENCODED VIDEO WITH “UP-THE-COAX” EXTENDED DISTANCE OR BI-DIRECTIONAL DATA (RS232, RS422 RS485 2/4W)
The FTV/FRV10D1(M,S)1(ST,FC) series transmits 10 bit digital video and
NTSC, PAL and SECAM CCTV camera systems. The data supports RS232,
RS422 and RS485 (2W & 4W) at data rates up to 115 Kbps (NRZ). The FTV/
FRV10D1(M,S)1(ST,FC) series also supports “Up-the-Coax” control signals
for Pelco Coaxitron. The product is “Plug-and-Play” with no electrical or optical
adjustments.
The FTV/FRV10D1(M,S)1(ST,FC) series allows the user to choose
bi-directional data or up-the-coax data through a switch on the unit, as
described in Figure 5 on Page 4.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining
equipment operating status. Figure 6 on Page 4 describes the LED indicators
for each light on the unit.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 6 for installation instructions.
See Figures 1 – 7 for complete installation details.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C5633M-A / REV 07-24-14
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C5633M-A / REV 07-24-14
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOIN
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOIN
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
GND
+Vin
PWR
OPTICAL
IN/OUT
VIDEOOUT
B
A
DOUT-
DOUT+
DIN-
DIN+
GND
DIN
DOUT
232485422
DATA
INSTALLATION AND OPERATION MANUAL FTV/FRV10D1(M,S)1(ST,FC)
FIGURE 1 – FTV/FRV10D1(M,S)1(ST,FC) SERIES TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK WITH WHITE STRIPES
BLACK Power Supply: Surface Mount: 8–15 VDC @ 2W Rack Mount: From Rack NOTE: Remove Electrical Connector for Rack Mount Units Above wiring assumes use of Pelco FEXTPS power supply. When using non-Pelco power supplies, confirm polarity before connecting.
FIGURE 2 – TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FTV10D1S1ST
VIDEO
TRANSMITTER
+ 2 WAY DATA / UP the COAX
VIDEOIN
LINK
VIDEO
DATA IN
DATAOUT
POWER
12
ON
DOUT
DIN GND DIN+
DIN­DOUT+ DOUT-
GND
+Vin
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
IN/OUT
OPTICAL
DATA
232485422
A B
PWR
FIGURE 3 – RECEIVER
FRV10D1S1ST
VIDEO
RECEIVER
+ 2 WAY DATA / UP the COAX
LINK
VIDEO
DATA IN
DATAOUT
ON
12
POWER
VIDEOOUT
DOUT
DIN GND DIN+
DIN­DOUT+ DOUT-
GND
+Vin
IN/OUT
OPTICAL
DATA
232485422
A B
PWR
C5633M-A / REV 07-24-14
INSTALLATION AND OPERATION MANUAL FTV/FRV10D1(M,S)1(ST,FC)
12
ON
DATAOUT
DATA IN
VIDEO
LINK
FTV10D1S1ST
VIDEO
TRANSMITTER
+ 2 WAY DATA / UP the COAX
FIGURE 4 – DATA CHANNEL CONNECTIONS
FIGURE 5 – SWITCH POSITIONS
The mode for each data channel is configured using a pair of switches on the front panel of the unit.
Switch
FIGURE 6 – LED INDICATORS
GREEN Communication link
RED Communication
OFF Unit powered down.
1 2
Up-the-Coax
Protocols
LINK VIDEO DATA IN DATA OUT POWER
has been established
over optical fiber
link has not been established.
An active video signal
is present on the BNC
connector.
An active data signal
is present on the
input pins of the data
connector.
1 2
RS485
4-Wire Data
An active data signal
is present on the
output pins of the
data connector.
1 2 1 2
RS232 Data RS422,
Unit powered up
RS485 2-Wire,
Manchester or
Bi-Phase Data
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C5633M-A / REV 07-24-14
INSTALLATION AND OPERATION MANUAL FTV/FRV10D1(M,S)1(ST,FC)
FIGURE 7 – DATA CONNECTIONS
UTC Control
RS232
RS422
Customer
Equipment
Up-the-Coax
Control Receiver
Customer
Equipment
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (–)
Data In (+)
Data In (–)
Transmitter
VIDEO IN
Transmitter
DIN
DOUT
GND
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
Receiver
VIDEO OUT
Receiver
DOUT
DIN
GND
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
Customer
Equipment
Up-the-Coax
Control Transmitter
Customer
Equipment
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (–)
Data Out (+)
Data Out (–)
Bi-phase or
Manchester
2-Wire
RS485
4-Wire
RS485
Data Out (+)
Data Out (–)
Data (A)
Data (B)
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(–)
A
B
A
B
DOUT(+)
DOUT(–)
DOUT(+)
DOUT(–)
A
B
DOUT(+)
DOUT(–)
A
B
Data In (+)
Data In (–)
Data (A)
Data (B)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C5633M-A / REV 07-24-14
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, the manufacturer recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
FIGURE A
Dimensions are for a standard one slot module
.2cm
[5.2in]
11.9cm [4.7in]
7. 5cm
0.63cm [0.25in]
[2.9in]
15cm
[5.9in]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
2.75cm [1.1in]
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C5633M-A / REV 07-24-14
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•Five years: –Fiber optic products – Unshielded Twisted Pair (UTP) transmission products –CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
• Three years: –FD Series and BU Series analog camera models –Fixed network cameras and network dome cameras with Sarix –Sarix thermal imaging products (TI and ESTI Series) –Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,
and C10CH Series) – EH1500 Series enclosures –Spectra –Spectra HD dome products –Camclosure
®
IV products (including Spectra IV IP)
®
IS Series integrated camera systems
– DX Series video recorders (except DX9000 Series which is covered for a
period of one year), DVR5100 Series digital video recorders, Digital Sentry
Series hardware products, DVX Series digital video recorders, and NVR300
Series network video recorders
®
– Endura – Genex
Series distributed network-based video products
®
Series products (multiplexers, server, and keyboard) – PMCL200/300/400 Series LCD monitors –PMCL5xxF Series and PMCL5xxNB Series LCD monitors
•Two years: –Standard varifocal, fixed focal, and motorized zoom lenses – DF5/DF8 Series fixed dome products
®
–Legacy –Spectra III
Series integrated positioning systems
, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, ExSite IP, and
PS20 scanners, including when used in continuous motion applications – Esprit Ti and TI2500 Series thermal imaging products – Esprit and WW5700 Series window wiper (excluding wiper blades) –CM6700/CM6800/CM9700 Series matrix – Digital Light Processing (DLP
®
) displays (except lamp and color wheel). The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.
®
technology
•Six months: – All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes)
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization
®
following information:
number (RA), and provide the
1. Model and serial number
2. Date of shipment, P. O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
Revised 1-12-12
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pe .cnI ,ocleP ,2102 thgirypoC © .setailiffa sti ro .cnI ,ocl All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.
www.pelco.com
co, Inc.
Pel
625 W. Alluvial, Fresno, California 93711 United States USA & Canada Tel (800) 289-9100 Fax (800)
289-9150 I
nternational Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.com
Loading...