8/97Changed fusing values for fuse #F2, Figure 1 per ECO#
C554M-A5/98Rev A. Changed manual to new format and manual
93-362.
pagination. Included the CE version metal box receiver/
drivers.
Pelco Manual C554M-A (5/98)3
(This page intentionally left blank.)
4Pelco Manual C554M-A (5/98)
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1.Installation and servicing should only be done by qualified service personnel
and conform to all local codes.
2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or
6P enclosure, it is designed for Indoor use only and it must not be installed
where exposed to rain and moisture.
3.Only use replacement parts recommended by Pelco.
4.After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C554M-A (5/98)5
1.2 REGULATORY NOTICES
NOTE: This equipment has been tested and found to comply with the limits of a
Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However there is no guarantee that
the interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
1.3 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
The following items are supplied:
1CX9000 Series Coaxitron® Receiver/Driver
1Installation/Operation Manual (C554M-A)
Be sure to save the shipping carton, boxes and inserts. They are the safest material
in which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its box
and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement.
(International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN INFORMATION section of this manual for instructions.
1.4 RECOMMENDED TOOLS
Pelco does not supply the basic tools needed for the installation process. The following tools are recommended.
Medium adjustable wrench or socket wrench
Medium Phillips screwdriver (to open anodized metal box)
Power drill
Wire stripper
Wire cutter
AMP type crimper
6Pelco Manual C554M-A (5/98)
2.0 DESCRIPTION
The Coaxitron® receiver/driver operates on the principle of transferring control information and video on the same line. A train of pulses containing control information is superimposed on the video at VIS time. This transmitted train of control information can originate from a variety of Pelco controllers, including the CM6700,
CM7500, CM8500, CM9500, CM9760-CXT, MPT9000, and MPT9008.
Depending on receiver/driver options, wiring and controller capabilities, the possible range of control information that can be transferred, acted upon and augmented by the receiver is covered by the following list of functions:
1. Pan Left9.Iris Open
2. Pan Right10. Iris Close
3. Tilt Up11. Camera Power On/Off
4. Tilt Down12. Auto/Manual Scan
5. Zoom In13. AUX 1 (Manual Iris)
6. Zoom Out14. AUX 2 (Auto Iris)
7. Focus Near15. AUX 3
8. Focus Far16. AUX 4
When used with a CX900TLC Local Test Board Plug-in Module, manual control of
functions can be performed from the receiver location for local operation and to
check for the valid reception of a given command from the controller.
Pan/tilt, zoom lens and camera power control is included on the main (video and
logic) receiver board, which eliminates malfunctions due to improper wiring or broken wires.
The receiver/driver includes the following standard functions on a single circuit board
and chassis with integral power supply:
1.Pan/tilt (24 VAC or 120 VAC as ordered from the factory)
2.Zoom lens – Zoom, iris, and focus with adjustable speed (speed not remote
controllable)
3.Camera power (24 VAC or 120 VAC as ordered from the factory)
4.An open collector transistor output (latching) intended for use in manual override of an automatic iris control
Pelco Manual C554M-A (5/98)7
2.1 MODELS
Outdoor
CX9024RXCoaxitron® outdoor receiver for 24 VAC pan/tilts with power
CX9024RX/220Same as CX9024RX except 230 VAC input and CE compliant.
CX9024RX-12VSame as CX9024RX except 12 VDC camera power. (UL)
CX9024RX-PP*Same as CX9024RX except with preset option. (UL)
CX9024RX-PP220* Same as CX9024RX-PP except 230 VAC input and CE compli-
CX9115RXCoaxitron® receiver for 120 VAC pan/tilts with power supply for
CX9115RX-PP*Same as CX9115RX except with preset option. (UL)
CX9220RXCoaxitron® receiver for 230 VAC pan/tilts with power supply for
CX9220RX-PP*Same as CX9220RX except with preset option.
CX9224RXSame as CX9024RX except 24 VAC input. (UL)
CX9224RX-PP*Same as CX9224RX except with preset option.
Indoor
supply for pan/tilt, zoom lens, 24 VAC camera power. 120 VAC
input. (UL)
pan/tilt, zoom lens, 230 VAC camera power. 230 VAC input and
CE compliant.
CX9024RXISame as CX9024RX except for indoor use. (UL)
CX9024RXI-12VSame as CX9024RXI except 12 VDC camera power. (UL)
CX9024RXI-PP*Same as CX9024RXI except with preset option. (UL)
CX9115RXISame as CX9115RX except for indoor use. (UL)
CX9115RXI-PP*Same as CX9115RXI except with preset option. (UL)
CX9220RXISame as CX9220RX except for indoor use.
CX9220RXI-PP*Same as CX9220RXI except with preset option.
CX9224RXISame as CX9224RX except for indoor use. (UL)
CX9224RXI-12VSame as CX9224RXI except with 12 VDC camera power.
CX9224RXI-PP*Same as CX9224RXI except with preset option. (UL)
* Receivers with the preset designation (PP) are for use with preset capable
Coaxitron® controllers. Controllers with preset ability include the CM6700, CM7500,
CM8500, CM9500, and CM9760-CXT.
8Pelco Manual C554M-A (5/98)
2.2 CERTIFICATIONS
The products identified below have been tested and certified for agency compliance as noted below.
ModelCEFCCULCSA/cUL
CX9024RXXX
CX9024RX-12VXX
CX9024RX-PPXX
CX9024RX-PP220X
CX9024RX/220X
CX9024RXIXX
CX9024RXI-12VXX
CX9024RXI-PPXX
CX9115RXXX
CX9115RX-PPXX
CX9115RXIXX
CX9115RXI-PPXX
CX9220RX
CX9220RX-PP
CX9220RXI
CX9220RXI-PP
CX9224RX
CX9224RX-PPXX
CX9224RXIXX
CX9224RXI-12VXX
CX9224RXI-PPXX
Agency Compliance Certification