Pelco CC3551H-2, C1984M-F, CC3651H-2X User Manual

®
Installation/Operation
CC3551H-2 and CC3651H-2X DSP Color Camera
C1984M-F (4/03)
Pelco World Headquarters • 3500 Pelco Way, Clovis, CA 93612-5699 USA • www.pelco.com
USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150
International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
11. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, the apparatus does not operate normally, or the apparatus has been dropped.
12. Apparatus shall not be exposed to dripping or splashing, and no objects filled with liquids, such as vases, shall be placed on the apparatus.
13. Warning: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
14. Caution: Danger of explosion if battery is replaced incorrectly. Replace only with the same or equivalent type.
15. To reduce the risk of shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
16. Use only installation methods and materials capable of supporting four times the maximum specified load.
17. Use only UL listed class 2 power supply.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are impor-
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
tant operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
2
Pelco Manual C1984M-F (4/03)
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device many not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
DESCRIPTION
The CC3551H-2 and CC3651H-2X are high resolution, color video cameras with a 1/3-inch CCD imager. The cameras feature digital slow shutter (DSS) mode, a direct drive/auto iris lens connector, adjustable back focus, backlight compensation, automatic gain control, and an adjustable C/CS lens mount.
Models
CC3551H-2 High resolution, 480 TV lines, HyperHAD™ CCD, minimum illumination of 0.035 lux at
CC3651H-2X High resolution, 470 TV lines, EXviewHAD™ CCD, minimum illumination of 0.02 lux at
f1.2 and 50 IRE, NTSC format (CE, UL, cUL)
f1.2 and 50 IRE, PAL (CE, UL, cUL, UL AR-S)
Pelco Manual C1984M-F (4/03)
3
CAMERA LAYOUT
BACK FOCUS ADJUSTMENT LOCKING SCREW
MOUNT ADAPTER
PHASE ADJUSTMENT
LEVEL ADJUSTMENT
POWER SUPPLY
COSMETIC TRIM RING
Note: The cosmetic trim ring conceals the
BACK FOCUS ADJUSTMENT RING
LED light for more descreet surveillance operations. The trim ring also hides the
BNC VIDEO CONNECTOR
LENS CONNECTOR
LED
DIP SWITCHES
power connectors and protects the DIP switches.
Figure 1. Camera Layout
INSTALLATION
Lens Mounting
The camera can use a fixed iris, manual iris or auto iris lens. The camera is factory set for a CS-mount lens, but is easily adjusted for a C-mount lens.
1. C-Mount Lens Only - Rotate the back focus adjustment fully counterclockwise before install-
ing the C-mount lens (refer to the section on
Back Focus Adjustment
).
2. Remove the cosmetic trim ring from the back of the camera (refer to Figure 1). Set the lens mode
selector switch on the side of the camera to AIV (auto iris video drive lens) or AID (auto iris DC drive lens). Refer to the
Switch Settings
section. Switch setting is determined by the type of lens used.
3. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space between the
lens and the CCD element. If necessary, use clean, compressed air to remove any foreign matter.
4. Thread the lens cable through the cosmetic trim ring.
5. Connect the auto iris lens to the four-pin connector located on the side of the camera. Pin connec-
tions for the iris drive connector are as follows:
PIN DC AUTO IRIS LENS VIDEO AUTO IRIS LENS
3 4
1 Control coil negative (-) Lens positive supply
2 Control coil positive (+) Not used
3Drive coil positive (+) Video drive signal
12
4Drive coil negative (-) Ground
Figure 2. Lens Connections