01215
MRD1400HZ16
Camera Control
Interface for the
CC1400HZ16
Installation/
Operation Manual
C1973M-B (8/03)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
CONTENTS
LIST OF ILLUSTRATONS
Section Page
IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3
DESCRIPTION ................................................................................................................... 4
INSTALLATION .................................................................................................................. 4
DIP SWITCH SETTINGS ........................................................................................... 4
BAUD RATE SELECTION ................................................................................. 4
MRD ADDRESS SETTINGS .............................................................................. 5
MRD1400HZ16 INSTALLATION METHODS ............................................................. 6
WALL MOUNTING ............................................................................................. 6
DF5/DF8 SERIES DOME INSTALLATION ........................................................ 6
EH3512 SERIES ENCLOSURE INSTALLATION .............................................. 8
EH2512 SERIES ENCLOSURE INSTALLATION .............................................. 9
CONTROL, POWER, AND CAMERA CONNECTIONS ............................................10
OPERATION ..................................................................................................................... 11
TROUBLESHOOTING ...................................................................................................... 12
WARRANTY AND RETURN INFORMATION.................................................................... 12
Figure Page
1 SW-1 Default Switch Settings ............................................................................ 4
2 Wall Mounting .................................................................................................... 6
3 DF5/DF8 Installation .......................................................................................... 7
4 Removing the MRD Board ................................................................................. 7
5 Installing the EH3512 Adapter ........................................................................... 8
6 Installing the MRD Board onto the EH3512 Adapter .......................................... 8
7 EH2512 Series Enclosure Installation ................................................................9
8 Control, Power, and Camera Connections ........................................................ 10
9 Multiple Units with Parallel Connections ........................................................... 10
10 Data Cable Wiring .............................................................................................10
LIST OF TABLES
Table Page
A Baud Rate Switch Settings ................................................................................ 4
B MRD DIP Switch Settings .................................................................................. 5
C Two-Wire Control Connections .........................................................................10
2 Pelco Manual C1973M-B (8/03)
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. There are no user-serviceable parts inside this unit. Only authorized service personnel
may open the unit.
3. To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture if
this unit is designed for indoor use only.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit.
This symbol indicates that there are important operating and maintenance instructions
in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
Pelco Manual C1973M-B (8/03) 3
DESCRIPTION
The MRD1400HZ16 is a camera interface control for Pelco’s CC1400HZ16 Series digital
color camera. The unit can be mounted directly to a wall or installed in a DF5 Series dome,
DF8A Series dome, EH2512 Series enclosure, or EH3512 Series enclosure.
The MRD1400HZ16 can be used with the following Pelco controllers and matrix switchers:
INSTALLATION
DIP SWITCH SETTINGS
NOTE:
Settings – If switch settings
are changed while the power
to the MRD unit is ON, push
and hold the reset button for
five seconds and then
release, to recycle power
and accept the new baud/
address setting. Refer to
Figure 4 for the location of
the reset button.
Baud/Address
Controllers (direct mode only) MPT9500, CM9760-KBD Series, KBD200A,
and KBD300A
Matrix Switchers CM6700 Series, CM6800 Series, CM9740
(configured for D or P protocols only) Series, and CM9760 Series
The following items are supplied:
Qty. Item
1 MRD1400HZ16
1 DF5/DF8/EH2512 Series adapter
1 EH3500 Series adapter
1 4-pin connector
1 Data cable (12 inches)
4 4-40 Phillips button head screws
1 #10 nut and washer
1 Camera sled for EH3500 Series enclosure
BAUD RATE SELECTION
The baud rate must be set for the MRD1400HZ16 to automatically sense D or P protocol.
The default communication rate for the MRD1400HZ16 is 4800 baud. If the system’s controller/switcher uses a different communication rate, change the baud rate of the
MRD1400HZ16 to match the controller/switcher.
To change the baud rate, refer to Figure 1 and Table A.
P
NOTE:
Dip switches 8, 9,
and 10 are factory set. Do
DATA
W
R
IN
SW1
RST
DATA
CAM
MRD1400HZ16
Made in USA
Table A. Baud Rate Switch Settings
Switch Setting
Baud
Rate
2400 OFF OFF
4800 ON OFF
9600 OFF ON
67
not change switch positions.
DEFAULT SWITCH
SETTINGS: 6 & 10 ON