Pelco C907M-A User Manual

®
WLVEH Enclosure
for
Wireless Control/Video Systems
Installation/Operation Manual
C907M-A (7/96)
Pelco • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-209) 292-1981
FAX (800) 289-9150 or (1-209) 292-3827 • DataFAX (800) 289-9108 or (1-209) 292-0435

TABLE OF CONTENTS

Section Page
1.0 WARNINGS........................................................................................................................................1
2.0 SCOPE...............................................................................................................................................2
3.0 DESCRIPTION...................................................................................................................................2
4.0 INSTALLATION...................................................................................................................................2
4.1 TRANSMITTER ........................................................................................................................2
4.2 RECEIVER ...............................................................................................................................2
5.0 SPECIFICATIONS ..............................................................................................................................3
6.0 EXPLODED ASSEMBL Y DIAGRAM ..................................................................................................4
6.1 MECHANICAL PARTS LIST.....................................................................................................5
7.0 WIRING DIAGRAM ............................................................................................................................5
8.0 WARRANTY AND RETURN ..............................................................................................................6

LIST OF ILLUSTRATIONS

Figure Page
1 WLVEH Outdoor Enclosure Exploded Assembly Diagram..............................................................4
2 WLVEH Outdoor Enclosure Wiring Diagam ....................................................................................5
REVISION HISTORY
Manual # Date Comments
C907M 1/95 Original manual. C907M-A 7/96 Complete revision to reflect redesign of unit.
11/96 Revised Figure 1 and installation instructions per ECO 96-284. Added
Section 7.0, “Wiring Diagram.”
®Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 1996, Pelco. All rights reserved.
ii Pelco Manual C907M-A (7/96)

INSTALLATION/OPERATION MANUAL WLVEH ENCLOSURE FOR WIRELESS CONTROL/VIDEO SYSTEMS

1.0 WARNINGS

Prior to installation and use of this product, the follow­ing WARNINGS should be observed.
1. Installation and servicing should only be done by
qualified service personnel and conform to FCC regulations and all Local codes.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. The product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
4. Only use replacement parts recommended by Pelco.
5. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C907M-A (7/96) 1

2.0 SCOPE

This manual covers the installation of the following wireless systems in the WLVEH outdoor enclosure:
WLV500 Series of control systems WLV2000 Series of video systems
5. Reinstall the transmitter mounting plate (11) in­side the enclosure. There are two sets of four mounting holes on the enclosure mounting plate (15). On units without an omnidirectional dipole antenna, use the top holes to provide more clear­ance for making connections to the transmitter.

3.0 DESCRIPTION

The WLVEH Enclosure is a NEMA-rated housing that protects the WLV500 Series of wireless control sys­tems and WLV2000 Series of wireless video systems in outdoor environments.
Input power to the enclosure is selectable from either 120 VAC, 24 VAC, or 230 VAC. The AC input is con­verted to a regulated 15 VDC to power the wireless system.
The enclosure can be mounted to a flat surface or to a pole when installed with Pelco's PA102 pole mount, and PA9000 pole mount adapter.

4.0 INSTALLATION

You can install either a wireless transmtter unit or a wireless receiver unit in the enclosure. Proceed to ei­ther Section 4.1, “Transmitter” or Section 4.2, “Re­ceiver.”

4.1 TRANSMITTER

Refer to Figure 1 to install the wireless transmitter . The following instructions apply to both the WLV500 and WLV2000 units.
1. Open the lid of the enclosure.
2. Remove the four screws that secure the transmit­ter mounting plate (item 11) to the enclosure mounting plate (15).
3. Install the transmitter to the transmitter mounting plate so that the electrical connections on the trans­mitter face the bottom of the enclosure. Use four small Phillips screws and lockwashers that are sup­plied with the transmitter.
4. If you have an omnidirectional dipole antenna, screw it onto the transmitter.
6. Connect the power leads inside the enclosure to the transmitter . The red wire attaches to the posi­tive (+) terminal and the black wire to the nega­tive (-) terminal.
7. There are two Phillips screws (I) on the bottom of the enclosure. Nothing is attached to them when a transmitter is installed in the enclosure.
8. Close the lid.
9. To complete the installation, refer to the instruc­tions for outdoor installation in your WLV500 or WLV2000 manual.

4.2 RECEIVER

Refer to Figure 1 to install the wireless receiver. The following instructions apply to both the WLV500 and WLV2000 units.
1. Open the lid of the enclosure.
2. Remove the four screws that secure the receiver mounting plate (item 11) to the enclosure mount­ing plate (15).
3. Install the receiver to the receiver mounting plate so that the electrical connections on the receiver face the bottom of the enclosure. Use four small Phillips screws and lockwashers that are supplied with the receiver.
4. Reinstall the receiver mounting plate (11) inside the enclosure. There are two sets of four mounting holes on the enclosure mounting plate (15). On units without an omnidirectional dipole antenna, use the top holes to provide more clearance for making connections to the bottom of the receiver.
5. Connect the power leads inside the enclosure to the receiver. The red wire attaches to the positive (+) terminal and the black wire to the negative (-) terminal.
2 Pelco Manual C907M-A (7/96)
6. There are two Phillips screws (I) on the bottom of the enclosure. If you are installing a WLV500 re­ceiver, they are not used. If your are installing a WLV2000 receiver, they are test points for mea­suring Received Signal Strength Indication (RSSI). Wire the test points as follows:

5.0 SPECIFICATIONS

Power Input: 24, 120, or 230 VAC
Construction: Fiberglass box with NEMA 4X rat-
ing
a. Solder one end of a wire to the solder lug on
receiver mounting plate. Solder the other end of the wire to the solder lug on the Phillips screw on the left (the screw to the left of I) on the bottom of the enclosure.
b. Solder one end of a wire to the solder lug on
the Phillips screw on the right (I) on the bot­tom of the enclosure. Screw the other end of the wire into the tip plug that is supplied.
c. Push the tip plug into the green connector on
the front of the receiver.
7. Attach the receive antenna (18) to the antenna mounting bracket (16).
8. Screw the connector on the end of the antenna cable onto the mating connector on the top of the receiver.
9. Close the lid.
10. To complete the installation, refer to the instruc­tions for outdoor installation in your WLV500 or WLV2000 manual.
IEC 144 Rating: IP66
Dimensions: 4.3" H x 11.5" L x 9.5" W
(10.92 x 29.21 x 24.13 cm)
Cable Entry: One (1) gland for power cord
Two (2) glands for video and audio coaxial cable
Locking Method: Latches with holes for padlocks
Weight (excluding wireless transmitter or receiver)
Enclosure: 8.6 lbs (3.90 kg) Shipping: 10.6 lbs (4.81 kg)
Pelco Manual C907M-A (7/96) 3

6.0 EXPLODED ASSEMBLY DIAGRAM

Figure 1. WL VEH Outdoor Enclosure Exploded Assembly Diagram

4 Pelco Manual C907M-A (7/96)
6.1 MECHANICAL PARTS LIST
Item Quantity Description Part Number
1 1 9-Pin Connector CON03-06-1091 2 2 Gland EH400010003 3 2 Gland Nut EH400010004 4 1 Gland CX950010000 5 1 Gland Nut CX950010001 6 2 Fuse Holder FUS342012L 7 1 Power Supply Assembly PCB9000281ASSY 8 1 3-Position T erminal Block TRB3-140Y
9 1 Transformer TRF21162.01.OCM 10 1 Power Cord (not shown) WIRC1318006BL 11 1 Transmitter/Receiver Mounting Plate WLV4100COMP 12 4 Fixed Tilt Bracket WLV4155COMP 13 4 Adjustment Bracket WLV4156COMP 14 1 Enclosure Box WLVEH4000COMP 15 1 Mounting Plate WLVEH4151COMP 16 1 Antenna Mounting Bracket WLVEH5152COMP 17 1 Wireless Transmitter or Receiver — 18 1 Receive Antenna — 19 2 1/4 Amp, Slow Blow, 3AG Fuse FUS1/4SB
A 8 Screw, 1/4-20 x 1/2-inch ZH1/4-20X.500CH
B 12 Split Lock Washer, 1/4-inch ZH1/4LWSSL
C 12 Flat Washer ZH260X562X65C D 4 Bolt, 1/4-20 x 5/8-inch ZH1/420X.625CH E 4 1/4-20 Nut ZH1/4-20NUTCH F 6 Screw, 10-32 x 1/2-ich, Pan Head, Phillips ZH10-32X.500SPP G 6 Internal Tooth Lock Washer, #10 ZH10LWSIS H 6 Flat W asher, #10 ZH204X436X60C
I 2 Screw, 8-32 x 1/2-inch, Flat Head, Phillips ZH8-32X.500SFS
J 4 8-32 Nut ZH8-32NUTSH
K 10 Screw, 6-32 x 3/8-inch, Pan Head, Phillips ZH6-32X.375SPP
L 12 Internal Tooth Lock Washer, #6 ZH6LWSIS M 8 Flat Washer, #6 ZH148X375X32C
N 4 6-32 Nut ZH6-32NUTSH O 2 Screw, 6-32 x 1/2-inch, Pan Head, Phillips ZH6-32X.500SPP P 4 Screw, 4-40 x 1/4-inch, Pan Head, Phillips ZH4-40X.250SPP Q 4 Internal Tooth Lock Washer, #4 ZH4L WSIS

7.0 WIRING DIAGRAM

NOTE: Output voltage is 15 VDC, not 10.5.

Figure 2. WL VEH Outdoor Enclosure Wiring Diagram

Pelco Manual C907M-A (7/96) 5

8.0 WARRANTY AND RETURN INFORMATION

WARRANTY

If a warranty repair is required, contact Pelco at (800) 289-9100 or (209) 292-1981 for a Repair
Authorization number (RA), and provide the following information:
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment. Exceptions to this warranty are as noted below:
Two (2) years on all standard motorized and fixed
focal length lenses.
Two (2) years on Legacy®, Intercept®, CM8500/ CM9500/CM9750 Matrix, and DF8 Fixed Dome products.
Two (2) years on WW5700 series window wiper (excluding wiper blades).
Two (2) years on cameras.
Six (6) months on all pan and tilts, scanners or
preset lenses used in continuous motion applications (e.g., preset scan, tour and auto scan modes).
Pelco will warranty all replacement parts and repairs for 90 days from the date of shipment. All goods for warranty work shall be sent freight prepaid to our Clovis, California facility. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco is not liable for any incidental or consequential expenses or liability incurred by the customer as a result of field repair, installation, or any other reason.
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
Method of return shipment shall be the same as method by which the repair item is received by Pelco.

RETURNS

In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289- 9100 or (209) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). Goods returned for repair or credit should be clearly identified with the assigned CA/RA number and freight should be prepaid. All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
The above warranty is in lieu of any other expressed or implied warranty, condition, or guarantee by Pelco of the equipment listed herein. Pelco makes no warranties except for intended use and will not be liable for any loss, damage, or costs arising, whether consequential or incidental, from the use of said merchandise.
This warranty gives you specific legal rights. You may also have additional rights, which are subject to variation from state to state.
6 Pelco Manual C907M-A (7/96)