INSTALLATION/OPERATION MANUAL
WLVEH ENCLOSURE
FOR WIRELESS CONTROL/VIDEO SYSTEMS
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1.Installation and servicing should only be done by
qualified service personnel and conform to FCC
regulations and all Local codes.
2.Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is
designed for indoor use only and it must not be
installed where exposed to rain and moisture.
3.The product may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
4.Only use replacement parts recommended by Pelco.
5.After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C907M-A (7/96)1
2.0 SCOPE
This manual covers the installation of the following
wireless systems in the WLVEH outdoor enclosure:
WLV500 Series of control systems
WLV2000 Series of video systems
5.Reinstall the transmitter mounting plate (11) inside the enclosure. There are two sets of four
mounting holes on the enclosure mounting plate
(15). On units without an omnidirectional dipole
antenna, use the top holes to provide more clearance for making connections to the transmitter.
3.0 DESCRIPTION
The WLVEH Enclosure is a NEMA-rated housing that
protects the WLV500 Series of wireless control systems and WLV2000 Series of wireless video systems
in outdoor environments.
Input power to the enclosure is selectable from either
120 VAC, 24 VAC, or 230 VAC. The AC input is converted to a regulated 15 VDC to power the wireless
system.
The enclosure can be mounted to a flat surface or to a
pole when installed with Pelco's PA102 pole mount,
and PA9000 pole mount adapter.
4.0 INSTALLATION
You can install either a wireless transmtter unit or a
wireless receiver unit in the enclosure. Proceed to either Section 4.1, “Transmitter” or Section 4.2, “Receiver.”
4.1 TRANSMITTER
Refer to Figure 1 to install the wireless transmitter . The
following instructions apply to both the WLV500 and
WLV2000 units.
1.Open the lid of the enclosure.
2.Remove the four screws that secure the transmitter mounting plate (item 11) to the enclosure
mounting plate (15).
3.Install the transmitter to the transmitter mounting
plate so that the electrical connections on the transmitter face the bottom of the enclosure. Use four
small Phillips screws and lockwashers that are supplied with the transmitter.
4.If you have an omnidirectional dipole antenna,
screw it onto the transmitter.
6.Connect the power leads inside the enclosure to
the transmitter . The red wire attaches to the positive (+) terminal and the black wire to the negative (-) terminal.
7.There are two Phillips screws (I) on the bottom of
the enclosure. Nothing is attached to them when a
transmitter is installed in the enclosure.
8.Close the lid.
9.To complete the installation, refer to the instructions for outdoor installation in your WLV500 or
WLV2000 manual.
4.2 RECEIVER
Refer to Figure 1 to install the wireless receiver. The
following instructions apply to both the WLV500 and
WLV2000 units.
1.Open the lid of the enclosure.
2.Remove the four screws that secure the receiver
mounting plate (item 11) to the enclosure mounting plate (15).
3.Install the receiver to the receiver mounting plate
so that the electrical connections on the receiver
face the bottom of the enclosure. Use four small
Phillips screws and lockwashers that are supplied
with the receiver.
4.Reinstall the receiver mounting plate (11) inside
the enclosure. There are two sets of four mounting
holes on the enclosure mounting plate (15). On
units without an omnidirectional dipole antenna,
use the top holes to provide more clearance for
making connections to the bottom of the receiver.
5.Connect the power leads inside the enclosure to
the receiver. The red wire attaches to the positive
(+) terminal and the black wire to the negative (-)
terminal.
2Pelco Manual C907M-A (7/96)
6.There are two Phillips screws (I) on the bottom of
the enclosure. If you are installing a WLV500 receiver, they are not used. If your are installing a
WLV2000 receiver, they are test points for measuring Received Signal Strength Indication (RSSI).
Wire the test points as follows:
5.0 SPECIFICATIONS
Power Input:24, 120, or 230 VAC
Construction:Fiberglass box with NEMA 4X rat-
ing
a.Solder one end of a wire to the solder lug on
receiver mounting plate. Solder the other end
of the wire to the solder lug on the Phillips
screw on the left (the screw to the left of I) on
the bottom of the enclosure.
b.Solder one end of a wire to the solder lug on
the Phillips screw on the right (I) on the bottom of the enclosure. Screw the other end of
the wire into the tip plug that is supplied.
c.Push the tip plug into the green connector on
the front of the receiver.
7.Attach the receive antenna (18) to the antenna
mounting bracket (16).
8.Screw the connector on the end of the antenna cable
onto the mating connector on the top of the receiver.
9.Close the lid.
10. To complete the installation, refer to the instructions for outdoor installation in your WLV500 or
WLV2000 manual.
IEC 144 Rating: IP66
Dimensions:4.3" H x 11.5" L x 9.5" W
(10.92 x 29.21 x 24.13 cm)
Cable Entry:One (1) gland for power cord
Two (2) glands for video and audio
coaxial cable
Locking
Method:Latches with holes for padlocks
Weight (excluding wireless transmitter or receiver)
Enclosure:8.6 lbs (3.90 kg)
Shipping:10.6 lbs (4.81 kg)
N46-32 NutZH6-32NUTSH
O2Screw, 6-32 x 1/2-inch, Pan Head, PhillipsZH6-32X.500SPP
P4Screw, 4-40 x 1/4-inch, Pan Head, PhillipsZH4-40X.250SPP
Q4Internal Tooth Lock Washer, #4ZH4L WSIS
7.0 WIRING DIAGRAM
NOTE: Output voltage is 15 VDC, not 10.5.
Figure 2. WL VEH Outdoor Enclosure Wiring Diagram
Pelco Manual C907M-A (7/96)5
8.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
If a warranty repair is required, contact Pelco at (800)
289-9100 or (209) 292-1981 for a Repair
Authorization number (RA), and provide the following
information:
Pelco will repair or replace, without charge, any
merchandise proved defective in material or
workmanship for a period of one (1) year after the date
of shipment. Exceptions to this warranty are as noted
below:
•Two (2) years on all standard motorized and fixed
focal length lenses.
•Two (2) years on Legacy®, Intercept®, CM8500/
CM9500/CM9750 Matrix, and DF8 Fixed Dome
products.
•Two (2) years on WW5700 series window wiper
(excluding wiper blades).
•Two (2) years on cameras.
•Six (6) months on all pan and tilts, scanners or
preset lenses used in continuous motion
applications (e.g., preset scan, tour and auto scan
modes).
Pelco will warranty all replacement parts and repairs
for 90 days from the date of shipment. All goods for
warranty work shall be sent freight prepaid to our
Clovis, California facility. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident
are not covered under this warranty. Pelco is not liable
for any incidental or consequential expenses or liability
incurred by the customer as a result of field repair,
installation, or any other reason.
1.Model and serial number
2.Date of shipment, P.O. number, Sales Order
number, or Pelco invoice number
3.Details of the defect or problem
If there is a dispute regarding the warranty of a product
which does not fall under the warranty conditions
stated above, please include a written explanation with
the product when returned.
Ship freight prepaid to:Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
Method of return shipment shall be the same as method
by which the repair item is received by Pelco.
RETURNS
In order to expedite parts returned to the factory for
repair or credit, please call the factory at (800) 289-9100 or (209) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA
number if returned for repair). Goods returned for
repair or credit should be clearly identified with the
assigned CA/RA number and freight should be prepaid.
All merchandise returned for credit may be subject to
a 20% restocking and refurbishing charge.
Ship freight prepaid to:Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
The above warranty is in lieu of any other expressed or
implied warranty, condition, or guarantee by Pelco of
the equipment listed herein. Pelco makes no warranties
except for intended use and will not be liable for any
loss, damage, or costs arising, whether consequential
or incidental, from the use of said merchandise.
This warranty gives you specific legal rights. You may
also have additional rights, which are subject to variation
from state to state.
6Pelco Manual C907M-A (7/96)