Pelco C808M-G, VS5008 User Manual

INSTALLATION/OPERATION
VS5004/VS5008
®
Sequential Switcher
Contents
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Terminated Camera Inputs and One Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Looping Camera Inputs and One Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Terminated Camera Inputs and Two Monitor Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Looping Camera Inputs and Two Monitor Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Coaxitron Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
List of Illustrations
1 VS5004 Terminated Camera Inputs - One Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 VS5008 Terminated Camera Inputs - One Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 VS5004 Alarm Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 VS5008 Alarm Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Looping Conversion Modification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6 VS5004 Looping Camera Inputs - One Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7 VS5008 Looping Camera Inputs - One Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
8 VS5004 Conversion For Two-Monitor Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
9 VS5004 Terminated Camera Inputs - Two Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
10 VS5008 Terminated Camera Inputs - Two Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
11 VS5004 Looping Camera Inputs - Two Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
12 VS5008 Looping Camera Inputs- Two Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
13 VS5004 with Coaxitron Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
14 VS5008 with Coaxitron Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
2 C808M-G (4/05)
Description
The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron mounted.

MODELS

VS5004 Sequential switcher with four camera inputs and two monitor outputs, 120 VAC VS5004/220 Same as VS5004 except 230 VAC VS5008 Sequential switcher with eight camera inputs and two monitor outputs, 120 VAC VS5008/220 Same as VS5008 except 230 VAC
®
compatible and can be placed on a desktop or rack
C808M-G (4/05) 3
a.
a.
Installation

TERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT

1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008).
VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output. The MON 1 output must
be terminated with a 75-ohm BNC terminator.
2. Make alarm connections if required. Refer to Figure 3 (VS5004) or Figure 4 (VS5008) and do the following:
VS5004
Input: Connect the alarm contact between the appropriate input (pins 1-4) and common (pin 5) on the 6-pin connector receptacle.
Pins 1 thru 4 directly correspond with the like-numbered front panel camera switches of the VS5004. The alarm output is an open-collector NPN transistor. Current from the output to circuit ground should not exceed 600 mA.
b. Output: To activate an external device during an alarm, connect the device at pins 5 and 6 on the 6-pin connector.
VS5008
Input: Connect the alarm contact between the appropriate ALARM INPUT (terminals 1-8) and common (COM) terminal. The alarm
output is an open-collector NPN transistor. Current from the output to circuit ground should not exceed 40 mA.
b. Output: To activate an external device during an alarm, connect the device at the ALARM OUT terminal and the common (COM)
terminal.
3. Set the ALARM switch to the ON position.
NOTES:
When an alarm occurs, the monitor immediately switches to the alarmed channel, and the associated LED blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008). The alarm has priority over the MONITOR/AUTO/BYPASS switch settings.
Once triggered, the alarm remains on until the input condition is removed or the ALARM switch is moved to the OFF position.
When the ALARM switch is set to the OFF position, all alarm inputs are ignored.
4. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switches set to the BYPASS position.
NOTE: All channels with a switch in the AUTO position will automatically sequence through the monitor. To view one specific channel
continuously, set the corresponding switch to the MONITOR position. To remove a channel from the sequence, set the corresponding switch to the BYPASS position.
5. Connect the AC adapter to the 12 VAC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 VAC (VS5004 or VS5008) or 230 VAC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing.
6. Using a screwdriver, adjust the DWELL interval control to the desired setting. This control adjusts the interval time from a minimum of 1 second to a maximum of 70 seconds nominal. To increase the interval, turn the control clockwise. To decrease the interval, turn the control counterclockwise. The DWELL interval control is a precision 15-turn potentiometer. Each complete turn of this control will adjust the time interval by approximately 4 to 5 seconds.
MON 1
BRIGHT CONTRAST
12 VAC
INPUT
ALARM
4321
MON 1
IN 1 2 3 4
MON 2
OUT 6 COMMON 5
Figure 1. VS5004 Terminated Camera Inputs - One Monitor
4 C808M-G (4/05)
NOTE: MON 1 MUST BE TERMINATED.
12 VAC
INPUT
ALARM
INPUT
12345678
COM
87654321
ALARM OUT
CAMERAS
VS5008 (REAR)
Figure 2. VS5008 Terminated Camera Inputs - One Monitor
REAR VIEW
MON 1
MON 2
CAMERAS
3
4
12
1234
ALARM
IN 1 2 3 4
OUT 6 -- TO VCR
COMMON 5
YEL
GRN
BLK
12VAC INPUT
MON 1
MON 2 MON X
6-PIN CONNECTOR
RECEPTACLE
4
5
6
BRN
1
RD
2
OR
3
TO EXTERNAL
ALARM CIRCUITRY
Figure 3. VS5004 Alarm Connections
C808M-G (4/05) 5
UP TO EIGHT ALARM INPUTS (ALARM INPUT FROM MOTION DETECTOR, DOOR CONTACT, ETC., THROUGH NORMALLY OPEN SWITCH). EACH ALARM DEVICE MUST BE CONNECTED TO THE "COM" TERMINAL.
UP TO EIGHT VIDEO INPUTS
VCR
12 VAC
INPUT
ALARM
INPUT
12345678
COM
87654321
ALARM OUT
CAMERAS
VS5008 (REAR)
OPEN COLLECTOR OUTPUT FOR VCR ACTIVATION IN ALARM CONDITION. ONLY ONE VCR CAN BE USED IN THIS CONFIGURATION.
Figure 4. VS5008 Alarm Connections
MON 1
MON 2 MON X
6 C808M-G (4/05)
Loading...
+ 14 hidden pages