Peerless has no afliation with Sony Corporation of America.
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 2
PARTS LIST
A
Description Qty.Part #
lock down plate 1125-1217
B 1/4-20 x 1.75" carriage bolt 4520-1017
C #14 x 2.5" hex head wood screw2500-1005
D 1/4-20 x 1.5" socket pin screw 4520-1256
E concrete anchor 2590-0320
F 1/4-20 slope nut 3530-0035
G plastic screw cap4590-1294
H 4 mm allen wrench1560-9646
I 1/4-20 plastic toggler4560-9708
J 1/4-20 nylock nut 2530-9413
A
BC
DE
H
F
G
I
J
Installation to Wood Stud Wall..................................................................Page 3
Installation to Solid Concrete or Cinder Block........................................Page 4
Installation to Metal Studs.........................................................................Page 5
Mounting Surface Lock down Installation...............................................Page 6
2 of 7
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 3
Installation to Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations
Use a stud nder to locate the edges of the stud. Use of an edge-to-edge stud nder is highly recommended.
1
Based on their edges, draw a vertical line down each stud center. Place lock down plate (A) on wall as a template.
Level, and mark the center of the two mounting holes. Make sure that the mounting holes are on the stud center
lines. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Secure using two #14 x 2.5" wood screws (C)
as shown below.
WOOD STUD
C
A
PlayStation® 3
3 of 7
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 4
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and
components.
Place lock down plate (A) on wall as a template. Level,
1
and mark the center of the two mounting holes.
Drill two 5/16" (8 mm) dia. holes to a minimum depth of
2.5" (64 mm). Insert anchors (E) in holes ush with wall
as shown. Secure using two #14 x 2.5" wood screws (C)
as shown in gure 1.4.
1
Drill holes and insert anchors (E).
concrete
surface
E
WARNING
• Tighten screws so that wall plate is rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
nishing material. If mounting to concrete surfaces
covered with a nishing surface is unavoidable,
the nishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer.
INCORRECTCORRECT
wall
plate
concrete
wall
plate
concrete
2
A
C
Place lock down plate (A) over anchors (E) and secure with
screws (C).
3
Tighten all fasteners.
SOLID CONCRETE
E
E
CINDER BLOCK
CUTAWAY VIEW
plaster/
dry wall
plaster/
dry wall
C
A
4 of 7
PlayStation® 3
Figure. 1.4
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 5
Installation to Metal Studs
) as shown in gure 1.3. Loosely fasten wall plate to wall using two
WARNING
• Drywall must be 1/2" or thicker, and metal stud must be 24 gauge or thicker.
• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and
components.
• Make sure that togglers are anchored into the center of the studs. The use of an "edge to edge" stud nder is highly
recommended.
Using a stud nder, locate and mark the edges of the metal stud used in mounting this product. Use of an edge to
1
edge stud nder is highly recommended. Use a level to draw a level, vertical line down the center of the stud. Level
wall plate (A), and mark the center of the two mounting holes. Make sure that the mounting holes are on the stud
center lines. Drill two 1/2" holes through drywall and metal studs. NOTE: It may be necessary to drill 5/32" pilot
holes prior to drilling 1/2" holes. Install togglers (I
1/4-20 x 1.5" screws (D) using 4 mm allen wrench (H) as shown in gure 1.4. Level, hold,
and then tighten all screws.
g. 1.3
METAL STUD
1
I
Pivot end of toggler (I).
drill
1/2"
hole
2
I
Push into hole.
3
I
Rotate toggler (I) clockwise to wedge it against
inside walls of metal stud.
4
I
I
A
D
PlayStation® 3
Figure. 1.4
Slide plastic cap forward while pulling back
rmly on ring.
5
I
Break off excess.
5 of 7
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 6
Installation to Drywall
WARNING
• Drywall must be 1/2" or thicker.
• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and
components.
Using lock down plate (A) as a template mark the center of the four mounting holes. Drill four 1/2" holes through
1
drywall. NOTE: It may be necessary to drill 5/32" pilot holes prior to drilling 1/2" holes. Install togglers (I) as shown
in gure 1.3. Loosely fasten lock down plate (A) to wall using four 1/4-20 x 1.5" screws (D) using 4 mm allen
wrench (H) as shown in gure 1.4. Level, hold, and then tighten all screws.
g. 1.3
1
I
Pivot end of toggler (I).
drill
1/2"
hole
I
DRYWALL
2
I
Push into hole.
3
I
Rotate toggler (I) clockwise to wedge it against
inside walls.
4
I
Slide plastic cap forward while pulling back
rmly on ring.
5
I
A
D
PlayStation® 3
Figure. 1.4
Break off excess.
6 of 7
ISSUED: 1-17-11 SHEET #: 125-9181-1
Page 7
Desktop Mounting Surface Lock down Installation
Place lock down plate (A) onto mounting surface as a template. Level, and mark the center of four rectangular
1
mounting holes. Drill four 5/16” (8 mm) dia. holes through desktop mounting surface. Secure using four carriage
bolts (B) though lock down plate (A) and mounting surface as shown in gure 1.1.
Secure two 1/4-20 x 1 3/4” carriage bolts (B) using two 1/4-20 nylock nuts (J) in corners as shown in gure 1.1.
Using remaining 1/4-20 x 1 3/4” carriage bolts (B), hand tighten slope nut (F) through 1/4-20 x 1 3/4" carriage bolt
(B) until snug against bottom of desktop surface as shown in gure 1.2. Thread another slope nut (F) upside-down,
about two turns from rst slope nut (F). Insert a open box wrench between both slope nuts (F) and tighten.
NOTE: Avoid jamming both slope nuts (F) together, doing so may make it difcult to remove slope nut used for tightening rst slope nut (F) as shown in gure 1.3. After slope nut is secure remove bottom slope nut and add plastic cap (G) as shown in gure 1.4. Repeat with remaining 1/4-20 x 1 3/4" carriage bolt (B).
B
TOP OF MOUNTING SURFACE
PlayStation® 3
J
B
BOTTOM OF MOUNTING SURFACE
F
F
A
Figure. 1.1
B
TIGHTENING
SLOPE NUT
F
Figure. 1.2Figure. 1.3
7 of 7