Concrete Ceiling Mount for Peerless® Outdoor Enclosures*
Models: FPECMC-01, FPECMC-02,
FPECMC-03, FPECMC-04
Max Load Capacity: 400 lb (181 kg)
*For use with Peerless
®
Outdoor Enclosures only
ISSUED: 08-09-10 SHEET #: 061-9058-4 10-18-10
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Due to outdoor environmental conditions such as strong wind gusts, heavy snow, hail, rain, etc. The environmental
enclosure mount, together with the enclosure, extension tube and hardware, must be inspected at least once a
year, and immediately following any time winds exceed 90 mph. A qualifi ed installer or inspector must check for
signs of rust, loose fasteners, bent metal, etc. If evidence of excessive wear, deterioration or any unsafe condition
is observed, this product must be taken out of service immediately. Direct all inquiries to customer care if you have
any questions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product was designed for use with other outdoor products only.
Tools Needed for Assembly
• 6mm allen wrench, 3/16" allen wrench
• drill
• 3/8" (10mm) bit for solid concrete
• level
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Solid Concrete ..................................................................................................................................................4
Installing Tilt Plate to Main Enclosure Assembly ....................................................................................................................6
Mounting Main Enclosure Assembly.......................................................................................................................................7
2 of 24
ISSUED: 08-09-10 SHEET #: 061-9058-4 10-18-10
Before you begin, make sure all parts shown are included with your product.
Parts List
DescriptionQty. Part #Model #Part #
adapter box
A
tilt plate
B
ceiling assembly
C
support column
D
M10 x 16mm socket screw4520-5013
E
Fsplit lock washer
1/4"-20 x 3/4" socket cap screw6520-5034
G
H1/4"-20 nylock nut
u-bolt with hex nuts2520-5037
I
carriage bolt3520-5039
J
3/8"-16 nylock nut3530-5004
K
concrete expansion anchor65M9-381-H03
L
5mm washer6540-5014
M
Parts may appear slightly different than illustrated.
• Concrete must be 3000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
Use ceiling plate (C) as a template to mark six mounting holes on concrete ceiling. Drill six 3/8" (10 mm) dia. pilot
1
holes to a minimum depth of 3". Place concrete expansion anchors (L) into ceiling and tighten to secure. Remove
bolt and washer from anchor housing. Place ceiling plate over anchors and secure with bolt and washer from
anchor housing. Tighten all fasteners.
WARNING
• Tighten screws so that ceiling assembly is fi rmly
attached, but do not overtighten. Overtightening
can damage screws, greatly reducing their holding
power.
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
fi nishing material.
CUTAWAY VIEW
L
C
WASHER (L)
BOLT (L)
1
Drill 3/8" (10 mm) dia. holes.
2
CONCRETE
SURFACE
concrete
surface
4 of 24
L
Tap concrete expansion anchors (L) into holes.
3
L
Tighten concrete expansion anchors (L) to secure to wall.
4
C
L
Unscrew bolt and washer from anchor housing, level wall plate (C)
on wall, and secure. Do not tighten in excess of 80 in•lbs (9.0 N.m.).
ISSUED: 08-09-10 SHEET #: 061-9058-4 10-18-10
Insert two M10 x 16 mm socket screws (E) and
2
two split lock washers (F) into bottom of adapter
box (A) leaving 1/4" exposed thread as shown in
fi gure 2.1 and detail 1.
A
fi g. 2.1
Insert one 3/8-16 x 4" fl at head bolt (J) through
3
bottom hole of support column (D) and secure with
3/8" nylock nut (K).
Set adapter box (A) onto support column (D).
A
F
1/4"
DETAIL 1
Unscrew hex nuts from u-bolts (I). Secure adapter
4
box (A) to support column (D) with two u-bolts (I)
and two hex nuts.
Adjust swivel of adapter box as shown and tighten
all fasteners.
D
E
D
J
K
Insert support column (D) into ceiling assembly
5
(C). Align holes of support column with holes of
ceiling assembly and secure using two 3/8-16 x 4"
fl at head bolts (J) and two 3/8" nylock nuts (K).
C
J
A
I
HEX NUTS (I)
5 of 24
K
D
ISSUED: 08-09-10 SHEET #: 061-9058-4 10-18-10
Installing Tilt Plate to Main Enclosure Assembly
WARNING
• Tighten screws so tilt plate (B) is fi rmly attached. Do not tighten with excessive force. Overtightening can cause
stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become
detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
NOTE: Follow instructions with main enclosure assembly for removal of bay door and vertical brackets.
6
Thread six 1/4-20 x .75" socket cap screws (G) with washers (M) through tilt plate (B), main enclosure assembly
(sold separately), seal washer (provided with enclosure assembly), and nylock nut (H) as shown below. Tighten all
fasteners using a 3/16" allen wrench.
G
M
MAIN ENCLOSURE
ASSEMBLY
SEAL WASHERS
H
B
MAIN ENCLOSURE ASSEMBLY MAY APPEAR SLIGHTLY
DIFFERENT THAN ILLUSTRATED - SHOWN WITHOUT
BAY DOOR AND VERTICAL BRACKETS
6 of 24
ISSUED: 08-09-10 SHEET #: 061-9058-4 10-18-10
Mounting Main Enclosure Assembly
WARNING
• Do not lift more weight than you can handle. Always use an assistant or mechanical lifting equipment to safely lift
and position the fl at panel screen.
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to
40 in. • lb (4.5 N.M.) maximum torque.
Hook tilt plate (B) onto bottom socket screws
7
threaded into adapter box (A) and select desired
tilt angle (0° to 20°) as shown in fi gure 7.1. NOTE:
Be sure split lock washer (F) is on outside of tilt
plate as shown in detail 2.
Insert two M10 x 16 mm socket screws (E) and
two split lock washers (F) through tilt plate (B) and
into top of adapter box (A) as shown in fi gure 7.2.
Tighten all fasteners using 6 mm allen wrench.
CAUTION
• Do not allow main enclosure assembly to hang freely
on wall box (A) when all four sets of M10 x 16 mm
socket screws (E) are not fully secured or mount may
come off of wall.
MAIN ENCLOSURE
ASSEMBLY
B
A
B
F
DETAIL 2
E
fi g 7.2
fi g 7.1
7 of 24