Peavey PV 2.6 C Operating Manual

A
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
A
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
CAUTION: Risk of electrical shock - DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to
qualified service personnel. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
appliance, read the operating guide for further warnings.
A
Este simbolo tiene el proposito de alertar al usuario de la presencia de “(voltaje) peligroso” que no tiene aislamiento dentro de la caja
de1
product0 que puede tener una magnitud suficiente coma para constituir riesgo de
corrientazo.
A
Este simbolo tiene el proposito de alertar al usario de la presencia de instruccones importantes sobre la operation y mantenimiento en la literatura que viene con el producto.
PRECAUCION: Riesgo de corrientazo - No
abra.
PRECAUCION: Para disminuir el riesgo de corrientazo, no
abra
la cubierta. No hay piezas adentro que el usario pueda
reparar. Deje todo mantenimiento a
10s
tecnicos calificados.
ADVERTENCIA: Para evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato
Antes de usar este aparato, lea
m&s
advertencias en la guia de operacibn.
A
Ce symbole est utilise pur indiquer a l’utilisateur la presence a
l’interieur
de ce produit de tension non-isolee
dangereuse pouvant
&tre d’intensite
suffisante pour constituer un risque de choc Clectrique.
A
Ce symbole est utilise pour indiquer a l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions sur l’utilisation et l’entretien (service) de l’appareil dans la litterature accompagnant le produit.
ATTENTION: Risques de choc Clectrique - NE PAS OUVRIR! ATTENTION: Afin de reduire le risque de choc blectrique, ne pas enlever le couvercle. 11 ne se trouve a
l’interieur
aucune piece pouvant
&tre
reparee par l’utilisateur. Confier l’entretien a un personnel qualifie.
AVERTISSEMENT: Afin de
prtvenir
les risques de decharge Clectrique ou de feu, n’exposez pas cet appareil a la pluie
ou a
l’humidid. Avant d’utiliser cet appareil, lisez les avertissements supplementaires situ& dans le guide.
A
Dieses Symbol
sol1
den Anwender vor unisolierten gefahrlichen Spannungen innerhalb des Gehauses
warnen,
die
von Ausreichender
St%rke
sind,
urn
einen elektrischen Schlag verursachen zu konnen.
A
Dieses Symbol
sol1
den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die
Handhabung und Wartung des Produkts betreffen.
VORSICHT: Risiko - Elektrischer Schlag! Nicht iiffnen! VORSICHT:
Urn
das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden
sich
keine Teile darin, die vom Anwender repariert werden konnten. Reparaturen nur von qualifiziertem Fachpersonal
durchfiihren
lassen.
ACHTUNG:
Urn
einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerat nicht dem Regen oder
Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
2
FRONT PANEL FEATURES
DDTTM
ACTIVE LED INDICATOR (1)
Illuminates when
DDTTM
compression is taking place. This LED becomes a clip indicator when the rear
panel
DDTTM
ENABLE/DEFEAT switch is in the DEFEAT position.
OPERATION NOTE: It is normal for the DDT
TM
LED(s) to flash occasionally during amplifier operation. If the LED(s) remain on continuously, additional headroom is needed. In some cases, this may mean that the particular application requires a more powerful amplifier.
POWER LED INDICATOR (2)
Illuminates when AC power is supplied to the amplifier.
CIRCUIT BREAKER (3)
This breaker is provided to limit the current to the associated power transformer and protect it from overheating and possible destruction due to fault conditions in the amplifier. The trip current values have been carefully chosen to allow continuous power output performance while still protecting the power transformer. Normally, these breakers should not trip unless there is a fault in the amplifier circuitry that draws excessive mains current. However, abnormal conditions such as a short circuit on either or both channels, or continuous operation at overload or clipping (especially into 4 ohm load) will cause the breaker to trip. If this occurs, turn the power switch off, then simply reset the breaker and correct the cause of the overload.
A
When tripped, the button on the breaker will be outward nearly
l/2”
and can be reset by
pushing inward. A normal reset button length is about
l/4”.
If this “thermal” type breaker does trip, simply pushing the button back in will reset it, after waiting a brief period of time to allow it to cool down. REMEMBER, ALWAYS TURN THE POWER OFF BEFORE RESETTING
THE BREAKER. If the breaker trips instantly each time you attempt to reset it, the unit
should be taken to a qualified service center for repair.
POWER SWITCH (4)
Depress to the “I” position to turn the amplifier on.
OPERATION NOTE: This unit is equipped with automatic resetting thermal protection. If extremely high
operating temperatures cause the protection circuit to engage, the unit will shut down. Once it has cooled sufficiently, the protection circuit will disengage and the amplifier will be re-enabled. Continued thermal cycling indicates a load problem exists (shorted cable or the total speaker load is too low), or there is inad-
equate ventilation.
3
Back Panel:
0
6
BACK PANEL FEATURES LINE CORD - 120 V products only (5)
A
For your safety, we have incorporated a three-wire line (mains) cable with proper grounding facilities. It is not advisable to remove the ground pin under any circumstances. If it is necessary to use the equipment without proper grounding facilities, suitable grounding adaptors should be used. Less noise and greatly reduced shock hazard exists when the unit is operated with properly grounded receptacles.
SPEAKER OUTPUTS (6)
A
Provided for connection of external speaker(s). Minimum total impedance is 4 ohms.
DDTTM
COMPRESSION (7)
Each of the two internal power amplifiers is equipped with Peavey’s patented
DDTTM
Compression. The DDT circuits will automatically engage to prevent clipping distortion within the power amplifiers. Compres­sion is defeated when the pushbutton is “in”.
DDTTM
should be enabled at all times to protect speakers.
INPUT SENSITIVITY (8)
Maximum input gain (minimum sensitivity rating) is achieved at the full clockwise setting. A setting of less than full clockwise will yield lower system noise at the expense of headroom. Calibration indicates sensitivity in
volts/dBV
necessary to attain full available output.
OPERATION NOTE: The input sensitivity rating of a power amplifier is the voltage level required to drive the
amplifier to full output.
CHANNEL INPUTS (9)
Standard
l/4”
phone jacks with a special switching function to allow two modes of operation:
a. For normal STEREO operation, each jack is used as the input to the respective channel
(see fig. 1).
b. For dual-channel MONO operation, the A input jack may be used by inserting the plug only to the
first “click” or detent (see fig. 2). In this mode, the signal source is applied equally to both channels.
4
SPECIFICATIONS
Output Power:
4 ohms,1 kHz
at 1% THD: 130 W RMS
8 ohms,1 kHz
at 1% THD: 100 W RMS
2 ohms not recommended
Rated Output Power:
4 ohms,
20 Hz to 20
kHz,
0.1% THD: 100 W RMS
8 ohms,
20 Hz to 20
kHz,
0.1% THD: 90 W RMS
Slew Rate:
Stereo mode, each channel: 20
volts/uSec
Total Harmonic Distortion:
20 Hz to
20
kHz @
rated power, 8 ohms: Less
than 0.1%
Input Sensitivity & Impedance:
(63
rated output power)
4 ohms:
1 .O V RMS, 0
dBV;
20 k ohms (26
dB)
Frequency Response:
+0,
-1
dB,
20 Hz to 30
kHz,
1 W RMS, 8 ohms
Damping Factor:
8 ohms, 1
kHz:
Greater than 200
Hum & Noise:
(below rated output power)
8 ohms, 100
dB,
unweighted
Power Consumption:
(63
rated output power)
Domestic: 600 watts, 60 Hz, 120 V AC
Export: 600 watts,
50/60
Hz, 230 V AC
Dimensions & Weight:
Height: 3.5”
Width:
19”
Depth: 9.6”
Weight: 15.6
Ibs.
A
Due to
OUT
efforts for constant improvements,
features and
specifications
listed herein
are
subject to change without notice.
5
Loading...
+ 11 hidden pages