Patton electronic 2025 User Manual

USER MANUAL
MODEL 2025
Parallel to Serial/ Serial to Parallel Interface Converter
CERTIFIED
An ISO-9001
Certified Company
Part # 07M2025-B Doc. #102041U,
Revised 1/23/08
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 2025 components to be
free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
1.1 RADIO AND TV INTERFERENCE
The Model 2025 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 2025 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 2025 does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
1.2 CE NOTICE
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.
1
1.3 SERVICE
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or,
support@patton.com.
NOTE: Packages received without an RMA number will not be
accepted.
Patton Electronics' technical staff is also available to answer any
questions that might arise concerning the installation or use of your Model 2025. Technical Support hours: 8AM to 5PM EST, Monday
through Friday.
2
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions arise during installation or use of the unit, contact Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or,
support@patton.com.
2.1 FEATURES
• Converts parallel data to serial data and vice versa
• Automatic parallel and serial sensing and selection
• Automatic DCE/DTE sensing and selection
• Serial data rates up to 38,400 bps
• No AC power required
• Supports both software and hardware flow control
• Ultra-miniature size
• A five-state LED monitors status and diagnostics
• Variety of connectors and cable lengths
• Made in USA
2.2 DESCRIPTION
The Patton Model 2025 Parallel to Serial Converters
automatically convert RS-232 serial data to parallel data format and vice versa. Incorporating advanced microprocessor technology, the Model 2025 is able to automatically sense and select parallel and serial modes, as well as DTE/DCE modes. The Model 2025 requires no AC power and supports serial data rates from 300 to 38,400 bps.
For easy configuration, the Model 2025 features a convenient set of configuration switches. The configuration switches allow the user to control baud rate, parity, word length and flow control. An easy-to-read LED indicator displays status and operating condition.
Housed in an ultra-miniature ABS plastic case, the Model 2025 measures only 2.62” x 1.26” x .76”. The Patton Model 2025 comes equipped with a DB-25 female connector on the serial side, and a Centronics 36 pin male connector on the parallel side. A six foot integral cable is also included.
3
3.0 CONFIGURATION
The Model 2025 is simple to install and designed for excellent reliability: just set it and forget it. The following instructions will help you set up and install the converters properly. If you have any questions, please call Patton Technical Support at (301) 975-1007.
3.1 CONFIGURATION SWITCHES
The Model 2025 uses a set of eight external DIP switches (see Figure 1) that allow configuration to a wide range of applications. Because all eight switches are in one externally accessible DIP switch package, there is no need to open the case for configuration. The configuration switches allow you to select data rates, parity, word length and flow control selection. The following section describes all switch locations, positions and functions.
Configuration
Switch
Figure 1. The location of the configuration switches
The Model 2025 uses a
miniature
configuration switch package (see Figure 2). To configure your unit, use a small screwdriver and gently push each switch to its proper setting. The ON and OFF positions are shown in Figure 2. Default settings for the DIP switches are shown in the table on the following page. Detailed settings follow the table.
12345678
OFF
Figure 2. The miniature configuration switch package
DHS-8
4
Loading...
+ 11 hidden pages