PASCO UI-5001 Reference Manual

Reference Guide
*013-14545*
PASCO
550 Universal
Interface
Model No. UI-5001
013-14545A
Table of Contents
Equipment ............................................................................................................................1
Introduction.......................................................................................................................... 2
Computer Requirements for the 550 Universal Interface ................................................2
General Operation Requirements and Setup .................................................................... 2
A. Operation Requirements and Precautions.................................................................................................................. 2
B. Connecting the 550 Universal Interface to Your Computer ...................................................................................... 3
C. Starting the 550 Universal Interface .......................................................................................................................... 4
D. Plugging a Sensor into the 550 Universal Interface .................................................................................................. 5
Using the 550 Interface as a Signal Generator .................................................................5
A. Connect the Interface................................................................................................................................................. 5
B. Setup the Signal Generator ........................................................................................................................................ 5
Troubleshooting ................................................................................................................. 6
Appendix A: Specifications ................................................................................................7
Appendix B: Compliance ....................................................................................................9
Appendix C: Frequently Asked Questions........................................................................9
Technical Support ............................................................................................................. 11
Warranty, Copyright and Trademark Information........................................................... 11
Product End of Life Disposal Information.......................................................................11
ii
UI-5001 550 Universal Interface
ON/OFF push button/ power indicator
Input ports for phono
plug sensors
Input ports for DIN
plug sensors
Output port (banana jacks)
for signal generator/power
output (up to 3.2 W)
Input ports for PASPORT sensors
Light emitting diode (LED) USB connection indicator
Light emitting diode (LED) Bluetooth connection indicator
USB Cable
AC Adapter
UI-5001 550 Universal Interface
Equipment
.
Included Equipment
1. 550 Universal Interface (UI-5001)
2. AC Adapter (with power cord)
3. USB cable
Additional Equipment Required Note
USB or Bluetooth compatible computer
Any PASCO® sensor
PASCO Data Collection Software
* Any PASPORT
1
See the PASCO web site at www.pasco.com for more information about software.
OR
Bluetooth compatible tablet
®
or ScienceWorkshop® sensor can be used for real-time data collection.
A sensor with a PS-, CI-, ME-, SN-, or TD- prefix*
PASCO Capstone or SPARKvue
1
Additional Equipment Recommended Model Number
Shrouded Banana Plug Patch Cords (for Output) EM-9740 (red) and EM-9745 (black)
1 013-14545A
Introduction UI-5001
®®
Introduction
Interface
The PASCO
®
550 Universal Interface is a multi-port data collection interface designed for use with any PASCO sensor and PASCO Data Collection software (available separately). Users can plug a sensor into one of the six input ports on the interface, perform the necessary setup in the Data Collection software and then begin collecting data. The software records, displays and analyzes the data measured by the sensor.
The 550 Universal Interface comes with a universal serial bus (USB) cable for connecting to a USB port, and a power supply (adapter with power cord) that converts input of 100 to 240 volts, alternating current (100 to 240V AC) to output of 15 volts, direct current, at two amps (15V DC at 2 A)
The 550 Universal Interface can also connect wirelessly to a Bluetooth-compatible computer or tablet.
The 550 Universal Interface has a built-in signal generator and power output. The power output ports provide up to 3.2 watts (W) of power. The interface can output direct current (DC) or alternating current (AC) in a variety of waveforms such as sine, square, and sawtooth. The interface has built-in voltage and current sensors that measure the output signal.
(Please note that the 550 Universal Interface is not compatible with the PASCO CI-6552A Power Amplifier because there is no ‘signal output’ from the DIN plug ports.)
Note: The 550 Universal Interface is compatible with all PASCO PASPORT sensors and ScienceWorkshop sensors. The PASPORT sensors have a “PS-” prefix, and the ScienceWorkshop sensors have a “CI-”, “ME-”, “SN-”, or “TD-” prefix. See the PASCO web site at www.pasco.com for more information about the sensors.
Computer Requirements for the 550 Universal Interface
Windows®-Based Computers: Windows™ XP SP2 (or higher), 2 GHz (or higher) processor, 200 MB (megabytes) available disk space, 2 GB (gigabytes) RAM (random access memory), display size 1024 by 768. [The interface cannot be used with Windows 3.1, 95, ME, 2000, or NT 4.0].
Macintosh Computers: Mac OS X 10.6 (or higher), Intel CPU, 100 MB available disk space, 2 GB RAM.
General Operation Requirements and Setup
A. Operation Requirements and Precautions
a) The 550 Universal Interface requires PASCO Capstone or SPARKvue software.
b) The included power supply (AC adapter) is required for operation. Always plug the power cord of the AC adapter into a standard, grounded wall outlet.
WARNING: The interface is not water-proof. To avoid the risk of shock, keep the interface,
AC adapter, and cable away from water and liquids. If conducting an experiment with liquids or water,
2 013-14545A