PASCO SF-9288 User Manual

Instruction Sheet for the PASCO Model SF-9288
Spectral Lamp Power Supply and Mount
➄➄
Allow about five minutes warm up time.
Introduction:
Always unplug before
removing cover of lamp.
Loosen
thumbscrew
to adjust
lamp height.
The PASCO Model SF-9288 Spectral Lamp Power Sup­ply and Mount is designed for use with Osram 9 pin DIN base, 21 mm diameter spectral lamps. The Mercury lamp (SF-9282) is available from PASCO scientific.
Mercury Spectral Lamp SF-9282 Sodium Spectral Lamp SF-9289 Cadmium Spectral Lamp SF-9290 Helium Spectral Lamp SF-9291 Neon Spectral Lamp SF-9292 Changing spectral lamps is easy, so a single power supply
can be used to power any one of the Osram lamps.
To use the Spectral Lamp Power Supply and Lamp:
➀➀
Insert a spectral lamp as shown on the back of this
➀➀
page.
➁➁
Plug the round, three-pronged plug from the lamp
➁➁
mount into the socket on the front of the power supply.
➂➂
Plug the power supply power cord into a grounded
➂➂
107-128 VAC, 60 Hz or 206-242 VAC, 50 Hz outlet. (See label on rear of unit).
➃➃
Flip the ON/OFF Switch on the front of the power
➃➃
supply to ON.
➄➄
If, at any time, the lamp fails to come on, check the fuse on the rear panel of the power supply. If the fuse is blown, replace only with a similarly rated fuse:
Fuse: 2 Amp
NOTE: To insert or change the spectral lamp,
follow the procedure shown on the back of this page.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER ON UNIT. NO USER SER­VICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user of the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magni­tude to constitute a risk of electric shock to persons.
The exclamation point within an equilat­eral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instruc­tions in the literature accompanying the appliance.
Hg Lamp Contains Mercury Manage in accordance with
disposal laws.
See https://www.lamprecycle.org/ or 1-866-666-6850
012-03048D
10101 Foothills Blvd.  Roseville, CA 95678-9011 USA
®
Phone (916) 786-3800  FAX (916) 786-8905  web: www.pasco.com
better
ways to
teach science
Spectral Lamp Power Supply and Mount 012-03048D
Replacing the Spectral Lamp
CAUTION HIGH VOLTAGE: Always
unplug the lamp mount from the power supply
➀➀
Unplug the Lamp Mount cord from
➀➀
the power supply, and allow several minutes for the lamp to cool.
➁➁
Unscrew and remove the top
➁➁
screws.
➂➂
Lift off the top.
➂➂
➃➃
Gently pull the spectral lamp up,
➃➃
out of the 9-pin socket.
CAUTION! WEAR GLOVES TO PROTECT
YOUR HANDS FROM A HOT LAMP OR POSSIBLE BREAKAGE.
➄➄
Reverse the procedure to replace the lamp.
➄➄
CAUTION! WHEN USING THE MERCURY
LAMP, SF-9282, DO NOT LOOK INTO LAMP. UV RAYS MAY BE DAMAGING. If the glass bulb is broken, immediately turn lamp off and remove it to avoid possible injury. Replace bulb prior to next use.
S1
117 VAC or 220 VAC
GROUND
COMMON
Schematic: Model SF-9288 Spectral Lamp Power
ON/OFF
F1
2 Amp
Supply and Mount
T2
T1
Limited Warranty
PASCO scientific warrants this product to be free from defects in materials and workmanship for a period of one year from the date of shipment to the customer. PASCO will repair or replace, at its option, any part of the product which is deemed to be defective in material or workman­ship. This warranty does not cover damage to the product caused by abuse or improper use. Determination of whether a product failure is the result of a manufacturing defect or improper use by the customer shall be made solely by PASCO scientific. Responsibility for the return of equipment for warranty repair belongs to the customer. Equipment must be properly packed to prevent damage and shipped postage or freight prepaid. (Damage caused by improper packing of the equipment for return ship­ment will not be covered by the warranty.) Shipping costs for returning the equipment, after repair, will be paid by PASCO scientific.
Equipment Return
Should this product have to be returned to PASCO scien­tific, for whatever reason, notify PASCO scientific by letter or phone BEFORE returning the product. Upon notification, the return authorization and shipping instruc­tions will be promptly issued.
NOTE:
FOR RETURN WITHOUT AN AUTHORIZATION.
When returning equipment for repair, the units must be packed properly. Carriers will not accept responsibility for damage caused by improper packing. To be certain the unit will not be damaged in shipment, observe the following rules:
➀➀
The carton must be strong enough for the item
➀➀
shipped.
➁➁
Make certain there is at least two inches of packing
➁➁
material between any point on the apparatus and the inside walls of the carton.
➂➂
Make certain that the packing material can not shift in
➂➂
the box, or become compressed, thus letting the in­strument come in contact with the edge of the box.
NO EQUIPMENT WILL BE ACCEPTED
2
®
Loading...