Instruction Sheet
for the PASCO
Model ME-9470
ADJUSTABLE DYNAMICS TRACK FOOT
Setup Procedure
1. Remove the existing fixed foot from the end of the
Dynamics Track.
2. Loosen the thumbscrew on the Adjustable Dynam-
ics Track Foot.
3. With the leveling feet aiming away from the under-
side of the track, slide the square nut of the adjustable foot into the slot on the side of the track.
NOTE: The flat side of the square nut must face the
outside of the Dynamics Cart Track as shown.
012-04992C
Introduction
The PASCO Model ME-9470 Adjustable Dynamics
Track Foot is designed for use as an accessory to any
PASCO Dynamics Track or Introductory Dynamics
System.
The Adjustable Dynamics Track Foot allows for a
greater range of adjustment and stability when performing experiments. It also permits the user to level
the track by raising or lowering the appropriate end. It
may be used in addition to or instead of the existing
fixed foot that is supplied as standard equipment on
either the 1.2 or 2.2 meter Dynamics Tracks.
Additional Equipment Required:
• Dynamics Cart Track, 1.2 meter (ME-9435A) or 2.2
meter (ME-9458)
• Dynamics Cart, such as Model ME-9430
Additional Equipment Recommended:
• Collision Cart, such as Model ME-9454
4. Position the foot as desired.
5. Retighten the thumbscrew.
6. Set the leveling feet at the desired height (for
stability).
7. Tighten the stabilizer nuts against the underside of
the foot.
NOTE: When adding other accessories through
the same track slot, you must first remove the
adjustable foot.
track
Square nut
Thumb screw
(617-002)
Foot
(648-07152)
(614-054)
Leveling foot 2X
(614-034)
Adjustment
screw 2X
(610-174)
012-04992C
Technical Support
For assistance with the Adjustable Dynamics Track
Foot or any other PASCO products, contact PASCO as
follows:
Address: PASCO scientific
10101Foothills Blvd.
Roseville, CA 95747-7100
Phone: (916) 786-3800
FAX: (916) 786-3292
Web: www.pasco.com
Email: techsupp@pasco.com
Limited Warranty
PASCO scientific warrants this product to be free from
defects in materials and workmanship for a period of
one year from the date of shipment to the customer.
PASCO will repair or replace, at its option, any part of
the product which is deemed to be defective in material
or workmanship. This warranty does not cover damage
to the product caused by abuse or improper use.
Determination of whether a product failure is the result
of a manufacturing defect or improper use by the
customer shall be made solely by PASCO scientific.
Responsibility for the return of equipment for warranty
repair belongs to the customer. Equipment must be
properly packed to prevent damage and shipped
postage or freight prepaid. (Damage caused by improper packing of the equipment for return shipment
will not be covered by the warranty.) Shipping costs
for returning the equipment, after repair, will be paid
by PASCO scientific.
2