Flex Rod
ME-8978A
Instruction Sheet
012-10009B
Included Equipment Included Equipment
1. Flexible Tubing 2. Rod Clamp
3. Lock Nut (2) 4. Three-finger Clamp
5. Base Adapter Rod 6. Double Clamp
7. Thumbscrew (2)
Introduction
The PASCO ME-8978A Flex Rod is a unique variation on the
traditional lab stand. Use it with a base or table clamp (sold separately) to support sensors, photogates, pulleys, diode lasers, test
tubes, and other lightweight equipment. The flexible
“goose-neck” tubing allows easily and accurate positioning by
bending the rod.
Sensors and other equipment can be screwed directly to Flex
Rod’s 1/4-20 threaded studs or held in the included rod clamp,
double clamp, or three-finger clamp. The rod clamp and double
clamp can also be screwed directly to Flex Rod’s threaded studs.
The rod clamp and double clamp hold cylindrical items up to 12
millimeters (mm) in diameter. The three finger clamp spans 62
mm when fully open.
Compatible Bases
The assembled Flex Rod can be mounted on any base or table
clamp that accepts an unthreaded 12.7 mm (0.5 inch) diameter
rod or a 1/2-13 threaded rod.
The table below lists compatible bases and table clamps available
from PASCO.
Compatible Base Part Number
Large Rod Base ME-8735
Small “A” Base ME-8976
Large Base and Support Rod ME-9355
Large Table Clamp ME-9472
Universal Table Clamp ME-9376B
800-772-8700 www.pasco.com
Model No. ME-8978A Set-up
Base Adapter
Rod
Flexible Tubing
Clamp or
screw into
base or
table clamp
Lock Nut
PASCO Sensor
Lock Nut
Flexible Tubing
Screw sensor
onto threaded
stud
Tighten nut
Rod Clamp
Lock Nut
Flexible Tubing
Screw clamp
onto threaded
stud
Tighten nut
Three-finger Clamp
Screw flexible rod
into Rod or Double
Clamp
Thumbscrew
Set-up
1. Screw one end of the flexible tubing through a lock nut into the
mating hole of the Base Adapter
Rod.
2. Secure the Base Adapter Rod in a
base or table clamp either by
clamping it or screwing it into a
1/2-13 threaded hole.
3. Screw a second lock nut onto the
threaded stud on the free end of
the Flexible Tubing.
4. If the equipment to be mounted
includes a 1/4-20 threaded hole
(such as a PASCO sensor), screw
it loosely onto the threaded stud; then tighten the lock nut
against it.
6. To attach the included three-finger clamp, first attach a rod
clamp or double clamp to the flexible tubing. Mount the
three-finger clamp in the rod clamp and tighten the thumbscrew to hold it in place.
Technical Support
For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone: 916-462-8384 (worldwide)
877-373-0300 (U.S.)
Web: www.pasco.com
Email: support@pasco.com
5. To attach the included rod clamp or double clamp, screw it
loosely onto the threaded stud; then tighten the lock nut
against it.
012-10009B
Limited Warranty
For a description of the product warranty, see the PASCO catalog.
Copyright
The PASCO scientific 012-10009B Flex Rod Instruction Sheet is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the
reproductions are used only in their laboratories and classrooms, and are
not sold for profit. Reproduction under any other circumstances, without
the written consent of PASCO scientific, is prohibited.
Trademarks
PASCO and PASCO scientific are trademarks or registered trademarks of
PASCO scientific, in the United States and/or in other countries. All other
brands, products, or service names are or may be trademarks or service
marks of, and are used to identify, products or services of, their respective
owners. For more information visit www.pasco.com/legal.
2