Paradyne TAM1500-12 User Manual

Interface Module User Guide
TAM1500-12
12-Port T1 Access Multiplexer
CAUTION
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this equipment.
INSTALLATION
1. Unpack and inspect the TAM1500-12.
If there is visible damage, do not attempt to connect the device; contact Customer Support at 1­877-638-2638 (001-603-427-0600 for international customers) or Support@NetToNet.com.
2. Install the TAM1500-12 in an IP DSLAM chassis.
NOTE
There must be a Multiplexer Uplink Module installed in the IP DSLAM chassis in order for Access Modules to operate.
a. Align the TAM1500-12 with the slot module guides of the chosen slot for installation (slot
1-12 on the IPD12000 or slot 1-4 on the IPD4000).
b. Slide the TAM1500-12 firmly into the chassis. DO NOT USE EXCESS FORCE.
c. Secure the TAM1500-12 by tightening the fastening screws on the module faceplate.
d. Verify that the PWR (Power) LED on the TAM1500-12 faceplate is illuminated.
210-0000025 rev04
3. Connect the T1 Line(s).
Plug the T1 cable into the RJ21 connector for the chosen slot on the back of the IP DSLAM. The TAM1500-12 will connect with remote T1 modems at distances up to 6,000 feet before requiring a T1 repeater. For each port being connected to a remote T1 modem, verify that the T1 link has been established; the T1 LK LED for that port will show steady illumination to indicate the connection has been made. Link up should occur within 20 seconds depending on the quality, gauge and distance of the copper cables. Default bandwidth for the TAM1500-12 is 1,536 kbps.
T1 RJ21 Connector Port Pinout
PORT 1 2 3 4 5 6 7 8 9 10 11 12 RX Tip 26 27 28 29 30 31 32 33 34 35 36 37 RX Ring 1 2 3 4 5 6 7 8 9 10 11 12 TX Tip 39 40 41 42 43 44 45 46 47 48 49 50 TX Ring 14 15 16 17 18 19 20 21 22 23 24 25
(Pins 13 and 38 are not used)
NOTE
Once the TAM1500-12 has been installed, all settings are software selectable via Net to Net Technologies' Network Management System (NMS). For further information regarding TAM1500-12 configuration and management please refer to the Circuit Configuration section further on in this manual and/or to the Management User Guide for IP and Mini DSLAMs.
OVERVIEW
TAM1500-12 Management
Statistical and configuration data for the TAM1500-12 are maintained in an embedded web server that resides within the firmware of Net to Net Technologies' Multiplexer Uplink Modules (MUMs). This firmware contains Net to Net's Network Management System (NMS) and Simple Network Management Protocol (SNMP).
Accessing TAM1500-12 data in a newly installed IP DSLAM
a. Connect your PC to the Ethernet RJ45 MGMT port located on the faceplate of the
MUM installed in your IP DSLAM.
b. Verify the connection; solid illumination of the MGMT LNK LED on the MUM
c. Launch a web browser such as Microsoft Internet Explorer (v4.0 or higher) or
d. Type the default IP address into the address field at the top of your browser and
210-0000025 rev04
faceplate indicates the connection has been established.
Netscape Navigator (v4.0 or higher).
press the Enter key.
192.168.254.252 if the MUM is in slot 13 (IPD12000) or slot 5 (IPD4000)
!
192.168.254.253 if the MUM is in slot 14 (IPD12000)
!
e. Log in with a default username and password (both of which are case sensitive).
Please note that General Users have "read only" access; for NMS configuration you must log in as a Superuser.
general / Password
!
superuser / Password
!
NOTE
Accessing TAM1500-12 data in a previously installed IP DSLAM
Once accessed initially, the management system within the MUM can be configured such that NMS and SNMP can be reached from any computer on your network. For further instruction please refer to the Management User Guide for IP and Mini DSLAMs.
a. Establish a connection with the MUM either directly (through the Ethernet RJ45
MGMT port on the MUM faceplate) or, if the system has been so configured, from a PC on your network.
b. For direct connections verify that the MGMT LNK LED on the MUM faceplate is
illuminated indicating the connection has been established.
c. Launch a web browser such as Microsoft Internet Explorer (v4.0 or higher) or
Netscape Navigator (v4.0 or higher).
d. Enter the assigned IP address* into the address field at the top of your browser
window. Press the Enter key.
e. Log in with your assigned username and password.* Please note that General Users
have "read only" access; for NMS configuration you must log in as a Superuser.
*If the IP address, username or password is unknown, contact your System Administrator or Information Technology Manager.
Default Settings
No configuration is necessary for the TAM1500-12 to operate at default settings. If however, a change is required, default settings can easily be modified within NMS. For information regarding specific parameter configurations, refer to the TAM1500-12 Circuit Configuration section on the following page and/or the Management User Guide for IP and Mini DSLAMs.
Management Password Administration Defaults*
General Username: general General Password: Password
*Usernames and passwords are case sensitive.
210-0000025 rev04
Super Username: superuser Super Password: Password
Loading...
+ 5 hidden pages