User Settings
For security reasons, write only the user’s name and not his or her access code. 4-Digit Codes N 6-Digit Codes N
User # and NamePartition 1 or 2BypStayForceArm OnlyPGM OnlyDuress
001: Master_______________________________1 & 2
002: Master1______________________________1
003: Master2______________________________2
004:_________________________________________NNNNNDuress: Y N N N
005:__________________________________________NNNNNDuress: Y N N N
006:__________________________________________NNNNNDuress: Y N N N
007:__________________________________________NNNNNDuress: Y N N N
008:__________________________________________NNNNNDuress: Y N N N
009:__________________________________________NNNNNDuress: Y N N N
010:__________________________________________NNNNNDuress: Y N N N
011:___________________________________________NNNNNDuress: Y N N N
012:__________________________________________NNNNNDuress: Y N N N
013:__________________________________________NNNNNDuress: Y N N N
014:__________________________________________NNNNNDuress: Y N N N
015:__________________________________________NNNNNDuress: Y N N N
016:__________________________________________NNNNNDuress: Y N N N
017:__________________________________________NNNNNDuress: Y N N N
>>>
>>>
>>>
018:__________________________________________NNNNNDuress: Y N N N
019:__________________________________________NNNNNDuress: Y N N N
020:__________________________________________NNNNNDuress: Y N N
021:__________________________________________NNNNNDuress: Y N N N
022:__________________________________________NNNNNDuress: Y N N N
023:__________________________________________NNNNNDuress: Y N N N
024:__________________________________________NNNNNDuress: Y N N N
025:__________________________________________NNNNNDuress: Y N N N
026:__________________________________________NNNNNDuress: Y N N N
027:__________________________________________NNNNNDuress: Y N N N
028:__________________________________________NNNNNDuress: Y N N N
029:__________________________________________NNNNNDuress: Y N N N
030:__________________________________________NNNNNDuress: Y N N N
031:__________________________________________NNNNNDuress: Y N N N
032:__________________________________________NNNNNDuress: Y N N N
N
Master Quick Menus
User
StepActionDetails
1
2[USERNUMBER]MG32LRF/MG32LED = 2 digits: 01 to 32
3[CODE]Enter 4- or 6-digit code.
4[CONFIRMCODE]Re-enter 4- or 6-digit code.
5[LEARNREMOTE] / [ENTER]Press a button on the designated remote or [ENTER] to skip. Goes to the next available
6[1] and/or [2] + [ENTER]Assign the user to one or both partitions and press [ENTER]. By default, users are
NotesBy default: User 1 has access to both partitions, User 2 has access to partition 1 only, and User 3 has access to parti-
[] + [
MASTERCODE]
tion 2 only. These settings cannot be modified.
Delays
StepActionDetails
The [ ] key will flash. LED/key on = programmed user.
[PARTITIONMASTERCODE] may also be used.
MG10LEDV/H =1 digit: 1 to 0(10)
user, or if partitioned, go to step 6.
assigned to partition 1. Goes to next available user.
1
2[TBL]
3[1] = Entry Delay 1 (sec.)
4[000] to [255]Enter a value between 000 and 255 (000 = default value).
2[TBL]
3[5]
4[HH:MM]Enter time. If HH = 13 or more, skip to step 6.
5[TIMEFORMAT]Enter time format ([1] = 24hr; [2] = AM; [3] = PM).
6[YYYY/MM/DD]Enter date.
[] + [
MASTERCODE]
The [ ] key will flash. [PARTITIONMASTERCODE] may also be used.
Communicate with WinLoad
StepActionDetails
1
2[MEM]
3[1] = Start communication
[] + [
MASTERCODE]
[2] = Cancel communication
The [ ] key will flash. [PARTITIONMASTERCODE] may also be used.
Communicator
StepActionDetails
1
[] + [
MASTERCODE]
The [ ] key will flash. [
PARTITIONMASTERCODE] may also be used.
2[MEM]
3[3] = Personal Phone #1
[4] = Personal Phone #2
[5] = Personal Phone #3
[6] = Personal Phone #4
[7] = Personal Phone #5
[8] = Pager #
4[PHONE #] + [ENTER]Enter phone # (up to 32 digits) and press [ENTER]. Goes to next phone#, or go to step 5
if [8] = Pager # was selected.
5[MESSAGE] + [ENTER]Step 5 for Pager # only. Enter pager message and press [ENTER].
Test Report
StepActionDetails
1
[] + [
MASTERCODE]
The [ ] key will flash. [
PARTITIONMASTERCODE] may also be used.
2[MEM]
3[2]Send a test report to the monitoring station.
Auto Arm
StepActionDetails
1
[] + [
2[BYP]
MASTERCODE]
The [ ] key will flash. [PARTITIONMASTERCODE] may also be used.
3[1] = Auto arm (partition 1)
[2] = Auto arm (partition 2)
4[HH:MM]Enter time (24Hr clock).
5[1] = Regular arm
[2] = Sleep arm
[3] = Stay arm
Erase Lost Remote Controls
StepActionDetails
1
[] + [
MASTERCODE]
The [ ] key will flash. [
PARTITIONMASTERCODE] may also be used.
2[BYP]
3[3]
4[ALLREMOTES] + [ENTER]Press a button on all remotes. Press [ENTER].
5Press and hold [SLEEP]
Press and hold [SLEEP] to erase all lost remotes.
(3sec)
System Options
StepActionDetails
1
[] + [
MASTERCODE]
2[BYP]
3[4] = Regular arm
[5] = Sleep arm
[6] = Stay arm
The [ ] key will flash. [
PARTITIONMASTERCODE] may also be used.
Toggle to have the siren squawk on arm/disarm with keypad.
Toggle to have the siren squawk on arm/disarm with remote.
Toggle to have no exit delay when arming with remote.
Table of Contents
User Settings..................................................... 0
System Checklist............................................. 16
Overview
Thank you for selecting the Magellan Security System from Paradox Security Systems Ltd. This advanced technology security system
provides you with reliable security protection and powerful features that anyone can use without memorizing complex and confusing
codes. The system consists of the Magellan control panel, one or more Magellan keypad modules, various input devices (e.g. motion
detectors, door contacts, etc.) and various output devices (e.g. bells, sirens, lights, etc.).
The elegant and user-friendly Magellan MG10LEDV/H, MG32LED, and MG32LRF keypad modules allow you to easily access your
security system's functions and provide you with an easy-to-understand display of your security system's alarm and operational status.
All of the actions performed in your security system will be executed and displayed through the keypad. Therefore, before using your
security system, we highly recommend that you read this manual carefully and have your installer explain basic system operation to you.
Basic Operations
Auditory Feedback
When you enter information on the keypad, it will guide you with beep tones that communicate acceptance or rejection of your
entries. You should be familiar with these two keypad beep tones:
Confirmation Beep: When an operation (e.g. arming/disarming) is successfully entered on the keypad or when the system switches
to a new status/mode, the keypad produces an intermittent beep tone (“
Rejection Beep: When the system reverts to its previous status or when an operation is incorrectly entered on the keypad, it will emit
a continuous beep tone (“
BEEEEEEEEP”).
Visual Feedback
Keypad Indicator Lights: All Magellan keypads include coloured lights which convey the current status of your system. The state of
each light represents a specific condition in your system.
Many of the features in your system must be enabled by the installer. If the feature is not programmed, the keypad will emit a rejection beep
and the action will be cancelled. Refer to
System Checklist on page 16 for details.
BEEP-BEEP-BEEP-BEEP”).
Overview of the Magellan Series Keypads
The numbers and keys of the Magellan series keypad’s screen communicate your system’s status.
Figure 1: MG10LEDV (10-zone LED Keypad Module)
Off Light (red):
On = Disarmed
Off = System armed
Fast Flash = Disarmed system in
*Audible Indicators:
Continuous beep = Alarm,
Variable beep = Fire alarm
Intermittent beep = Beginning of exit delay
Fast beep = Final 10 sec. of exit delay
lnfo Key
Refresh display to see all open zones (see
Display Mode on page 12)
[TBL] Trouble display
[MEM] Alarm memory display
On = StayD Enabled (see p.6)
ON = Trouble(s) occurring
[MEM] Alarm memory display
= Press once + [
CODE] for Quick Menu
Programming
MASTER
ON = Alarm(s) occurred
[BYP] Bypass programming
ON = Zone(s) bypassed
Partitioning
Your Magellan system is equipped with a partitioning feature that can divide your alarm system into two distinct areas identified as
Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as a
home office or warehouse building. When partitioned, each zone, each user code and many of your system's features can be
assigned to either Partition 1, Partition 2, or both partitions.
If the system is not partitioned, all zones, user codes, and features will be recognized as belonging to Partition 1.
Magellan5
StayD Mode
To Turn On/Off StayD Mode
To turn on StayD mode:
[STAY] + [CODE] + [STAY] StayD light on
Press the [
confirm StayD activation, and the system will be in Stay mode.
To turn off StayD mode:
[OFF] + [CODE] + [OFF] Off light on
Press the [OFF] key followed by a valid code, then press the [OFF] key again within ten seconds. The StayD light will turn off and the
Off light will light up to confirm StayD deactivation. With StayD disabled, the system will function as a standard security system.
To Change Arm Mode
To change the level of security - Stay to Sleep:
[SLEEP] for 2 sec. Delay Sleep light on
Press and hold the [
to the bedroom. When the exit delay ends, and you are in the bedroom, the rest of the interior will arm. The system is now in Sleep
mode.
To change the level of security - Sleep to Stay:
[STAY] for 2 sec. Stay light on
Press and hold the [
allowing you to leave the bedroom and move freely inside the house. If you accidentally leave the bedroom without switching to Stay
mode, all zones armed in Sleep mode will go into a delay, allowing you enough time to switch to Stay mode.
STAY] key followed by a valid code, then press the [STAY] key again within ten seconds. The StayD light will light up to
SLEEP] key on any keypad. All zones which will be armed in Sleep mode go into exit delay, allowing you to move
STAY] key on the keypad located in the bedroom. The system will instantly switch from Sleep to Stay mode,
Leaving the site - Stay to Full:
Keypad: [ARM] for 2 sec. Delay Arm light on
Remote: on remote
Press and hold the [ARM] key on the keypad that the exit path is assigned to. This will start an exit delay period for all zones in the
exit path. After you have left the property, all exit path zones will rearm. The system is now in Full mode.
Entering the site - Full to Stay:
Keypad: [CODE] Stay light on
Remote: on remote
When entering the property through the entry path, all zones assigned to the entry path will go into delay, allowing you to enter the
house. Entering a valid code on the keypad the entry path is assigned to ends the entry delay and switches the system to Stay Arm
mode. The entry path zones will rearm. The system is now in Stay mode.
Leaving the site without changing arm mode:
[OFF] for 2 sec.Press and hold the [
OFF] key for 2 seconds on a keypad to leave the site without changing arm mode.
Advanced StayD Settings
To open one window/door while inside:
[OFF] [CODE]
In a Stay-armed system: This mode allows you to open one exterior zone without triggering an alarm. To enter Window mode, press
OFF], then your [ACCESSCODE]. The system will start an exit delay, allowing you to open an exterior zone such as a window or a
[
door. The system will only allow you to open one zone as the exit delay will end after doing so. When you close the open zone
(window, door, etc.) that zone will re-arm.
Re-arm Delay:
Re-arm Delay is a delay timer set so that when you close the open exterior zone (window, door etc.), it does not re-arm instantly.
Instead the system starts a delay to allow you to close the zone properly. This is especially useful for windows that stick or for
reducing false alarms.
6User Guide
Access Codes
Programming Access Codes
Access codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your system as well
as activate or deactivate PGMs. The Magellan security system supports the following:
• 1 System Master Code
• 2 Master Codes
• 29 User Access Codes
For information on how each access code can arm or disarm the system refer to the System Checklist on page 16.
System Master Code (Default: 123456)
The System Master Code can arm or disarm any partition using any of the methods described in this section and can create, modify
or delete any user access code.
Master Codes
Master Code 1 is permanently assigned to Partition 1 and can be used to create, modify or delete user access codes that are
assigned to Partition 1.
Master Code 2 is permanently assigned to Partition 2 (Exception: When partitioning is disa bled, Master Code 2 will be assigned to
Partition 1) and can be used to create, modify or delete user access codes that are assigned to the same partition.
Master Codes cannot modify or delete user access codes assigned to both partitions. Only the System Master Code can modify or delete
user access codes assigned to both partitions.
Duress Code
If you are forced to arm or disarm your system, entering the access code with the duress option enabled will arm or disarm the
system and immediately transmit a silent alert (Duress Code) to the monitoring station.
Must be enabled by your installer.
Programming Access Codes
Your system can be programmed to use either 4- or 6-digit access codes, where each digit can be any value from 0 to 9. Six-digit
codes are considered more difficult to “crack” and therefore, more secure. Avoid programming simple or obvious access codes, such
as your telephone number, address or codes such as 1234. See Master Quick Menu on inside cover.
How do I program Access Codes?
1.Press the [] key.
2.Enter your [
3.The [] key will flash. When a zone LED or zone key is lit (not flashing), the user is alre ady programmed.
4.Select a user by entering a 2-digit user number (e.g. [0]+[9] for user 9) or use the scroll keys and then press [
MG10LEDV/H, press the key corresponding to the user number (e.g. [9] for user 9).
5.Enter a new 4- or 6-digit [
6.Confirm the code.
7.Press a button on the designated remote or press [
8.(Not available for non-partitioned system) Press [1] and/or [2] to assign the user to a partition. Press [
now jump to the next available user, if you choose to continue.
How do I delete Access Codes?
1.Press the [] key.
2.Enter your [
3.Select a user by entering a 2-digit user number (e.g. [0]+[9] for user 9). For the MG10LEDV/H, enter a 1-digit user number
(e.g. [9] for user 9).
4.Press and hold the [
SYSTEMMASTERCODE] or either [MASTERCODE].
ENTER]. For the
ACCESSCODE].
ENTER] to skip if there is no remote to program.
ENTER], the menu will
SYSTEMMASTERCODE] or either [MASTERCODE].
SLEEP] key until you hear the confirmation beep.
Magellan7
Arming & Disarming
Take full advantage of your Magellan system by familiarizing yourself with all the armi ng methods. If your system is not partitioned (see
Partitioning on page 5), everything is considered as belonging to Partition 1.
If you cannot arm because a zone is open, the system will enter in Bypass Programming. Enter the two digit zone you wish to bypass and press
[
ENTER], or press [ENTER] to bypass all open zones.
Regular Arming
This method will arm all the zones in the selected partition. Please note that Regular arming can also be activated using Auto-Arming (see
Auto-Arming on page 10) or One-Touch arming (see One-Touch Arming on page 9).
How do I Regular arm?
1.Close all zones in the desired partition.
2.Press [
3.If you have access to both partitions (see Partitioning on page 5): Press the key corresponding to the desired partition ([1] or [2]). For
Sleep Arming
Similar to Stay arming, Sleep arming allows users to remain in a protected ar ea, bu t provi des a h igh er level of prote ctio n. For example, in
a two-story house, the perimeter is protected with Stay arming. With Sleep arming, the perimeter as well as the main floor are protected
(motion detectors, etc.), allowing you to roam the second floor and sleeping quarters. Sleep zones are zones that are bypassed when
Sleep arming. For example, when you go to sleep at night, the entire premises except your bedroom is fully armed. Sleep arming can
also be activated using Auto-Arming (see Auto-Arming on page 10) or One-Touch arming (see One-Touch Arming on page 9).
ARM] + [ACCESSCODE].
both partitions, press the other key after the confirmation beep.
How do I Sleep arm?
1.Close all zones in the desired partition (except Sleep zones).
2.Press the [
3.Enter your [ACCESSCODE].
4.If you have access to both partitions (see Partitioning on page 5): Press the key corresponding to the desired partition, [1] or [2]. For
both partitions, press the other key after the confirmation beep.
SLEEP] key.
Stay Arming
This method allows you to roam freely within the premises while the perimeter is fully armed. Stay zones are zones that are bypassed
when Stay arming. For example, if you plan on staying in for the night, doors and windows can be armed without arming other zones like
motion detectors. Stay arming can also be activated using Auto-Arming (see Auto-Arming on page 10) or One-Touch arming (see One-
T ouch Arming on page 9).
How do I Stay arm?
1.Close all zones in the desired partition (except Stay zones).
2.Press the [
3.Enter your [ACCESSCODE].
4.If you have access to both partitions (see Partitioning on page 5): Press the key corresponding to the desired partition, [1] or [2]. For
both partitions, press the other key after the confirmation beep.
STAY] key.
8User Guide
One-Touch Arming
One-Touch arming allows you to arm the system without using an access code. This feature must be enabled by your installer.
If One-T ouch Arming is prog rammed, yo u can increase the security leve l of your system (from Disarm Stay Arm Sleep Arm Full Arm)
without a code. See Figure 4 on page 9.
One-Touch Regular Arming
Press and hold the [ARM] key for 3 seconds to arm all zones in the partition. If partitioned, keys [1] & [2] will flash. You can use this
feature to allow specific individuals like service personnel (e.g. cleaners) to arm without giving them access to any other alarm
system operations. For details see Regular Arming on page 8.
One-Touch Stay Arming
Press and hold the [STAY] key for 3 seconds to arm the perimeter (zones not defined as S tay zones). For details see S tay Arming on
page 8.
One-Touch Sleep Arming
Press and hold the [SLEEP] key for 3 seconds to arm all zones not defined as Sleep zones. For details see Sleep Arming on page 8.
One-Touch Bypass Programming
Press and hold the [BYP] key for 3 seconds to access Bypass Programming Mode. For details see Manual Bypass Programming on
page 10.
Fast Exit
When the system is already Stay or Sleep armed: This feature will allow you to exit already armed premises and keep the system
armed. Press and hold the [
its previous arming mode.
OFF] key for 3 seconds to start the exit delay. After the exit delay has elapsed, the system will switch to
To Disarm:
[
OFF] + Code
Figure 4: Arming/Disarming
ARM
To Sleep Arm:
[
SLEEP] + Code
No Code
SLEEP
No Code
No Code
STAY
To Disarm:
OFF] + Code
[
No Code
OFF
To Stay Arm:
[
STAY] + Code
To Disarm:
OFF] + Code
[
Magellan9
Auto-Arming
The Magellan alarm system can be programmed to automatically arm upon the following two conditions.
Timed Auto Arming
The alarm system can automatically arm itself at a specified time every day. As with Regular arming (see Regular Arming on page 8),
the system will bypass any open zones. Your installer can enable this option, but you can program the time of day the system will
automatically arm.
How do I program the Auto-Arm Timer?
1. Press the [] ke y.
2. Enter [MASTERCODE].
3. Press the [BYP] key. The [BYP] key will flash to indicate you are in the System Options menu.
4. Press key [1] to set partition 1, or press key [2] to set partition 2.
5. Enter the desired time for auto arm (24 hour clock, e.g. 18:30).
6. Press key [1] to regular arm, key [2] to sleep arm, or key [3] to stay arm the partition.
No Movement Auto Arming
The alarm system can be programmed to arm the system and/or send a report if no zone activity occurs for a pre-programmed
amount of time. This is a particularly useful feature when supervising an individual with chronic health proble ms or a person who
lives alone. The system will bypass any open zones. This feature must be set by your installer.
Disarming & Deactivating an Alarm
To disarm an armed system or an alarm, press [OFF] and enter your [ACCESSCODE]. An entry point, like the front door, will be
programmed with one of two Entry Delay Timers. When an entry point is opened, the keypad will beep until you disarm the system.
Your alarm system will not generate an alarm until this timer elapses. Any user can disarm a partition they have been assigned to,
except users assigned with the Arm Only Option or PGM Only Option.To disarm alarms generated by a Delayed Fire Zone, refer to
Fire Alarms on page 12.
How do I disarm the system?
For a Stay or Sleep armed system, go to step 2.
1.Enter through a designated entry point (e.g. front door).
2.Press [
3.If you have access to both partitions (see Partitioning on page 5): Press the key corresponding to the desired partition ([1] or [2]).
How do I deactivate an alarm?
OFF] + enter [ACCESSCODE].
For both partitions, press the other key after the confirmation beep.
Press [
OFF] + enter [ACCESSCODE].
Manual Bypass Programming
Manual Bypass Programming allows you to program the alarm system to ignore (deactivate) specified zones the next time the
system is armed. For example, you may wish to bypass certain zones when workers are renovating part of your establishment. Once
the system is disarmed, the bypass entries are erased. Manual Bypass Programming can also be activated by using One-Touch
Bypass Programming (see the note below). To remove the Bypass feature from a zone, in step 3 enter the zone number again or
CLEAR] to erase all current entries. When zones are bypassed, the [BYP] key will illuminate.
press [
How do I bypass zones?
1.Press the [
2.Enter [
3.Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the two-digit zone number (e.g. zone 3 =
03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
4.Press the [
If One-Touch Bypass Programming is enabled, press the [BYP] key for three seconds to enter Bypass Programming.
Press [
zones.
BYP] key.
ACCESSCODE] (see the note below). The [BYP] key will flash.
ENTER] key to save and exit.
ENTER] after step 2 to bypass all open zones. Press [CLEAR] twice to exit without saving. Press [CLEAR] + [ENTER] to delete bypassed
10User Guide
Bypass Recall Feature
After disarming the system, the bypass entries are erased. The Bypass Recall feature reinstates the previous bypass entries saved
in memory. This eliminates the need to manually re-program the bypass entries every time you arm the system.
How do I recall bypass entries?
1. Press the [
2. Enter your [ACCESSCODE]
3. Press the [BYP] key.
4. Press the [
BYP] key
ENTER] key.
Magellan11
System Features
Display Mode
(MG32LRF only)
The MG32LRF has two display modes. By default, the keypad will show all events (e.g. zones in alarm, bypassed zones, etc.) live as
they occur. Alternatively, the system can be programmed by your installer to only display zones that ca use an alarm or entry de lay. If you
want to see the status of all zones, press the [] key. Zones that are open but have not trigge red an alarm will only be displayed after
pressing the [] key. The information will be displayed for 30 seconds, showing the status of all zones at the time the [] key was
pressed. The zone display will shut off after 30 seconds. For more information on the two display modes, contact your installer.
Alarm Display
If an alarm has occurred on a zone, the respective zone LED will flash, the [MEM] key will light up, and the zones will be stored in memory.
These respective LEDs will continue to flash until disarming even if the zones are restored. To exit this mode and switch to live display
mode before disarming, press the [
lit. Press the [MEM] key to illuminate the LEDs corresponding to the zones that were in alarm. The alarm memory will be erased when the
next alarm occurs and after a valid code is entered.
Fire Alarms
Upon a fire alarm, the bell/siren will emit three “squawks” at 2 second intervals until silenced or reset by entering a vali d access code. If
the zone is a Delayed Fire Zone, there is a delay before the system contacts the monitoring station. This will prevent unnecessary
reporting of false alarms. If there is no fire condition, contact your monitoring station immediately to avoid an unnecessary response.
What do I do if a delayed fire zone was set off accidentally?
1. Press the [
2. Try to correct the problem.
3. If the problem persists, after 90 seconds, the alarm will sound again. Press the [
CLEAR]key within 30 seconds of the alarm.
CLEAR] key. When the system is disarmed, the zones’ LEDs will turn off, while the [MEM] key remains
CLEAR]key again.
Minimizing Fire Hazards
The three most common causes of fires:
• Cooking is the leading cause of home fires in the U.S. It's also the leading cause of fire injuries. Cooking fires often result from
unattended cooking and human error, rather than mechanical failure of stoves or ovens.
• Careless smoking is the leading cause of fire deaths. Smoke detectors and smolder-resistant bedding and upholstered furniture
are significant fire deterrents.
• Heating is the second leading cause of residential fires. However, heating fires are a larger problem in single family homes than in
apartments since the heating systems in single family homes are often not professionally maintained.
Fire Safety Tips
• In the event of a fire, escape first, then call for help. Develop a home fire escape plan and designate a meeting place outside. Make
sure everyone in the family knows two ways to escape from every room. Practice feeling your way out with your eyes closed. Never
stand up in a fire, always crawl low under the smoke and try to keep your mouth covered. Never return to a burning building for any
reason; it may cost you your life.
• Finally, having at least one working smoke alarm dramatically increases your chances of surviving a fire. And remember to practice
a home escape plan frequently with your family.
Providing a Fire Warning System
Household fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome occupants while they
sleep. To warn against fire, smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the
bedrooms and on each additional story of the family living unit, including basements.
Panic Alarms
In case of an emergency , the Magellan system can provide three panic alarms that can immediately generate an alarm after
simultaneously pressing and holding two specific keys for three seconds. Based on your needs, these panic alarms can generate audible
alarms (sirens or bells) or silent alarms and can communicate specific messages to your monitoring station. For instance, pressing [1]
and [3] can mean “call the police” or anything you require. This feature must be set by your installer.
Press and hold keys [1] and [3] for the police.
Press and hold keys [4] and [6] for a medical alarm.
Press and hold keys [7] and [9] for a fire alarm.
A Chime-enabled zone will advise you every time it is opened by causing your keypad to beep.
Each keypad must be Chimed separately.
How do I chime zones? MG32LED (32-zone Hardwired LED Keypad Modules only)
1. Press & hold the [
2. Select the numbers corresponding to the zones you want to Chime by entering the two-digit zone number. For example, to chime
zone 2 enter [0] then [2]. The corresponding LED will light up. The keypad will automatically save the information once the 2-digit
zone number is entered.
3. Press the [ENTER] key to exit.
T] key for 3 seconds. The Arm1, Arm2, Stay1, and Stay2 LEDs will flash.
To remove the Chime feature from a zone, in step 2 enter the zone number again so the number extinguishes or press [
remove Chiming from all zones programmed to Chime. Any zones that are already Chimed will also illuminate. Zones that remain unlit
are not Chimed.
How do I chime zones? MG10LEDV/H (10-zone LED Keypad Modules only)
1. Press & hold the zone key ([1] to [0(10)]) for 3 seconds. Accept beep = Chime on, Fail beep = Chime off.
SLEEP] to
Keypad Muting
When muted, the keypad will only emit the confirmation beep, rejection beep, and beep when a key is pressed. Therefore, when muted,
the keypad will not beep during an alarm and will not beep for chime enabled zones.
Press and hold the [
Muting is enabled for that keypad. If the keypad emits a rejection beep, the feature is disabled.
Each keypad must be muted separately.
CLEAR] key for 6 seconds to enable or disable Keypad Muting. If the keypad emits a confirmation beep, Keypad
Keypad Backlight
The illumination level behind the keys can be modified to suit your needs. There are four backlight levels. The [S] or [MEM] key is used
to set the desired level. Each consecutive push of the [
reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated.
How do I modify the backlight? MG32LED / MG32LRF (32-zone Hardwired & Wireless LED Keypad Modules only)
1. Press and hold the [S] key for 3 seconds.
S] or [MEM] key will increase the backlight level until the maximum level is
2. Press the [
3. Press [
How do I modify the backlight? MG10LEDV/H (10-zone LED Keypad Modules only
1. Press and hold the [
2. Press the [
3. Press [
S] key to set the desired backlight level.
CLEAR] or [ENTER] to exit.
MEM] key for 3 seconds. The [MEM] key will illuminate.
MEM] key to set the desired backlight level.
CLEAR] or [ENTER] to exit.
PGM Keys (Programmable Outputs)
Y our Magellan system may include one or more programmable outputs (PGMs). When a specific event or condition occurs in the system,
The PGM can be used to reset smoke detectors, activate light switches in your home or office, open/close garage doors and much more.
If programmed by your installer, you can press and hold keys [1] & [2], [2] & [3], [4] & [5], [5] & [6], [7] & [8], or [8] & [9] for each
respective PGM. Press and hold [
your installer.
Magellan13
CLEAR] + [ENTER] or [] for three seconds to perform a smoke reset. These features must be set by
Power Save Mode
(MG32LRF - Wireless Keypad Modules only)
If there is power loss on the keypad, the module’s display will shut off and go into power save mode after one minute. Press the [INFO]
key to activate the display.
Trouble Display
Your alarm system continuously monitors several trouble conditions that can be reported directly to your monitoring station. When a
trouble condition occurs, the [
allow them to service your system.
The keypad can be programmed to emit a
“Trouble Beep”.
How do I access the Trouble Display?
1.Press the [
The [TBL] key will flash and number(s) corresponding to the trouble(s) will illuminate.
2.Read the corresponding explanation of the trouble from the Trouble List below . If no repa ir instructions are given, call your
monitoring station for repairs.
3.Press the [CLEAR] key to exit.
TBL] key.
Trouble List
[1] Wireless Zone Low Battery: The battery voltage in one or more wireless zones is getting low.
[2] Power Trouble: Five types of power trouble - [1] The control panel is experiencing low/no battery. [2] There is an AC failure on
the control panel. [3] There is an auxiliary overload on the control panel. [4] A wireless keypad is experiencing
AC failure. [5] A wireless keypad is experiencing battery failure.
TBL] key will illuminate. We strongly suggest that you inform your monitoring station of the trouble and
BEEP every 5 seconds whenever a new trouble condition has occurred. Press the [TBL] key to stop the
[3] Bell Trouble: There is a bell disconnect/overload on the control panel.
[4] Communication Trouble: Your alarm system, if monitored, could not communicate with the monitoring station.
[5] Tamper/Zone Wiring Failure: A wiring problem is occurring on one or more zones.
[6] Module Tamper Trouble: A module’s anti-tamper switch has been triggered.
[7] Fire Loop Trouble: Indicates a wiring trouble on a fire zone.
[8] Timer Loss: Your alarm system’s clock must be reprogrammed. This is the only trouble that we recommend that you
correct.
How do I reprogram the clock?
1.Press [8] for Timer Loss.
2.Enter the hour and minutes. If the hour is between 01 and 12, you will need to select [1] for 24Hr format, [2] for AM, and [3] for
PM setting. If the hour is above 12, the system will automatically select the 24Hr format.
3.Enter the year (4 digits).
4.Enter the month (2 digits).
5.Enter the day (2 digits). You have now set the Time & Date. Press [
[9] Wireless Zone Supervision Loss: One or more wireless zones are no longer communicating with the control panel.
[10] Module Supervision Loss: One or more modules are no long er communicating with the control panel.
CLEAR] to exit.
[16] Keypad Fault (MG32LED/MG32LRF only): One or more keypads are no longer communicating with the control panel.
SLEEP] Keypad Fault (MG10LEDV/H only): One or more keypads are no longer communicating with the control panel.
[
14User Guide
Advanced Features
Quick Function Keys
Upon request of your installer or monitoring station you may have to perform one of the following. To enter Menu Programming, press
[] and then enter your [MASTERCODE]. In Menu programming, press:
Test Report
[MEM] + [2]
If your system is monitored by a monitoring station, this feature will send a test report code to the monitoring station.
Call PC
[MEM] + [1]
Will initiate a call to the monitoring station that is using the WinLoad software.
Answer PC
[MEM] + [1]
Will force your security system to answer a call made by your monitoring station that is using the WinLoad software.
Cancel Communication
[MEM] + [9]
Cancels all communication with the WinLoad software if it has been initiated.
Testing & Maintenance
With the system disarmed and the “OFF” light illuminated, activate motion de te c to rs by walking in the protected area. Open and close
protected doors and verify that the corresponding lights illuminate. Your installer can advise you of the best way to test your particular
system.
Do not use open flame or burning materials to test your fire detection devices. Contact your installer for safe methods of testing your
system.
Under normal use, your system requires virtually no maintenance other than regular testing. It is recommended that the standby battery
be changed every three years. Speak to your installer about the necessary tests and how often they should be performed.
Magellan15
System Checklist
Zone # and Description
01:__________________________________________
02:__________________________________________
03:__________________________________________
04:__________________________________________
05:__________________________________________
06:__________________________________________
07:__________________________________________
08:__________________________________________
09:__________________________________________
10:__________________________________________
11:__________________________________________
12:__________________________________________
13:__________________________________________
14:__________________________________________
15:__________________________________________
16:__________________________________________
17:__________________________________________
18:__________________________________________
19:__________________________________________
20:__________________________________________
21:__________________________________________
22:__________________________________________
23:__________________________________________
24:__________________________________________
25:__________________________________________
26:__________________________________________
27:__________________________________________
28:__________________________________________
29:__________________________________________
30:__________________________________________
31:__________________________________________
32:__________________________________________
Partition
1 or 2
BypStaySleepForce24HrEntry DelayFire Zone/Delay
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
NN NN N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
Fire Zone? Y
Delayed? Y N N N
Fire Zone? Y N N N
Delayed? Y N N N
N N N
16User Guide
Zone Description
Is this system partitioned? Yes N No N
Partition 1 = _____________________________________
Partition 2 = _____________________________________
Special Keys and Features
N [ARM]One-Touch Regular arming is activated
N [STAY] One-Touch Stay arming is activated
N [SLEEP]One-Touch Sleep arming is activated
N [BYP]One-Touch Manual Bypass Programming is
Panic Alarms
activated
[1] & [3] Police or __________N Silent N Audible N Off
[4] & [6] Aux. or ___________N Silent N Audible N Off
[7] & [9] Fire or ___________
Enter and exit your premises through the designated doors.
Exit Delay 1 (Partition 1): _______sec. = time to exit premises
Exit Delay 2 (Partition 2): _______sec. = time to exit premises
Entry Delay 1 = _______sec. = time to disarm before alarm; enter through zone #___________
Entry Delay 2 = _______sec. = time to disarm before alarm; enter through zone #___________
Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or
implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller d oe s no t
install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the se curity syste m and sh all no t b e
responsible for circumstances resulting from the product’s inab ility to o perate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not
meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct
or indirect or consequential or i nci de ntal, including without limitation, any damages for l ost pr of i t s st ol en go od s, or cl a ims by a ny o the r party, caused by defective goo ds or ot her w is e a r isin g fr o m the i mp rope r,
incorrect or otherwise faulty installation or use of the merchandise sold.
Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this p r odu ct sig nifies your a ccep tance of this warranty.
BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller.
Limitations of Alarm Systems
We strongly advise that you review and take into consideration the “Limitations of Alarm Systems” document available on our website at http://paradox.com/Terms/.
Warning for Connections to Non-Traditional Telephony (e.g. VoIP)
Paradox alarm equipment was designed to work effect ively aro und trad itiona l te leph on e syste ms. For t hose cu stomers wh o a re usin g a Pa ra do x ala rm panel connected to a non-traditional telephone system,
such as "Voice Over Internet Protocol" (VoIP) that converts the voice signal from your telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as
effectively as with traditional telephone systems.
For example, if your VoIP equip ment ha s no ba tte ry ba ck-u p, during a po wer failure you r system's ability to tran smit signal s to the cen tral station may be compromised. Or, if your VoIP connection becomes
disabled, your telephone line monitoring featu re may also be com promise d. Other conc erns would in clude, wit hout limi tation , Internet conn ection fai lures whic h may be mo re frequ ent than re gula r telephon e line
outages.
We therefore strongly recommend that you di scuss the se an d o the r limitations involved with operating an alarm system on a V oIP o r other non- traditional telepho ne system with your installat ion comp any. They
should be able to offer or recommend measures to re duce th e risks invo lved an d g i ve yo u a be tte r und erstanding.