1. The following functions are built in.
(1) Auto Light Control (ALC)/Electronic Light
Control (ELC)
(2) Automatic Gain Control (AGC) +15 dB
and Automatic Tracing White Balance
(ATW)
(3) Camera synchronization mode selec-
table between internal (INT), Line-locked
(LL) and Multiplexed Vertical Drive (VD2)
for WV-CP230 and WV-CP234.
FEATURES
2. Minimum illumination of 0.6 lx (0.06 foot-candle) at F0.75 (equivalent to 2.0 lx (0.2 footcandle) at F1.4)
3. Signal-to-noise ratio of 50 dB
4. Horizontal resolution of 480 lines
5. Auto iris lens control selectable between
video signal and DC power supply.
1. Do not attempt to disassemble the camera.
To prevent electric shock, do not remove
screws or covers.
There are no user serviceable parts inside.
Ask a qualified service person for servicing.
2. Handle the camera with care.
Do not abuse the camera. Avoid striking,
shaking, etc. The camera could be damaged
by improper handling or storage.
3. Do not expose the camera to rain or
moisture, or try to operate it in wet areas.
Turn the power off immediately and ask a
qualified service person for servicing.
Moisture can damage the camera and also
create the danger of electric shock.
4. Do not use strong or abrasive detergents
when cleaning the camera body.
Use a dry cloth to clean the camera when
dirty.
In case the dirt is hard to remove, use a mild
detergent and wipe gently.
5. Clean the CCD faceplate with care.
Do not clean the CCD with strong or abrasive
detergents. Use lens tissue or a cotton tipped
applicator and ethanol.
6. Never face the camera towards the sun.
Do not aim the camera at bright objects.
Whether the camera is in use or not, never
aim it at the sun or other extremely bright
objects. Otherwise, blooming or smear may
be caused.
7. Do not operate the camera beyond the
specified temperature, humidity or power
source ratings.
Use the camera under conditions where temperature is between –10°C - +50°C (14°F 122°F), and humidity is below 90 %. The
input power source is 120 V AC 60 Hz for
WV-CP230, 12 V DC for WV-CP232, and 24 V
AC 60 Hz for WV-CP234.
PRECAUTIONS
Color CCTV Cameras
WV-CP230/WV-CP232/WV-CP234
Before attempting to connect or operate this product,
please read these instructions completely.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER (OR
BACK), NO USER SERVICEABLE PARTS
INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
The lightning flash with arrowhead
symbol, within an equilateral triangle, is interned to alert the user to
the presence of uninsulated "dangerous voltage" within the product's
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
The serial number of this product may be found on
the top of the unit.
You should note the serial number of this unit in the
space provided and retain this instruction as a permanent record of your purchase to aid identification
in the event of theft.
Model No.
Serial No.
SA 1966
SA 1965
Caution:
To prevent fire or electric shock hazard, UL
listed wire VW-1, style 1007 should be used
for the DC 12 V or AC 24 V Input Terminal.
Cautions:
• Connect to 12 V DC (10.5 V-16 V) or 24 V
AC (19.5 V-28 V) class 2 power supply only.
Make sure to connect the grounding lead to
the GND terminal when the power is supplied from a 24 V AC power source.
• To prevent fire or electric shock hazard, UL
listed wire VW-1, style 1007 should be used
for the DC 12 V or AC 24 V Input Terminal.
VIDEO OUT
GND
AC 24V IN
12
VIDEO OUT
<WV-CP230>
<WV-CP234>
<WV-CP232>
DC 12V IN
VIDEO OUT
LL INT
ELC ALC
SOFT SHARP
OFF BLC ON
DC VIDEO
LL INT
ELC ALC
SOFT SHARP
OFF BLC ON
DC VIDEO
ELC ALC
SOFT SHARP
OFF BLC ON
DC VIDEO
WV–
CP230
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
q Auto Iris Lens Connector
Supplies power and control signals to an auto
iris lens (not supplied).
w Flange-back Adjusting Ring
This ring adjusts the back-focal distance or
picture focus. Rotate this ring clockwise for a
C-mount lens or counterclockwise for a CSmount lens.
e Lens (option)
r Camera Mounting Screw Hole
This hole is for mounting the camera onto a
mounting bracket. The camera is originally
designed to be mounted from the bottom, but
a top-mounting type is also available. To
mount from the top, remove the mount
adapter from the bottom of the camera by
removing two fixing screws. Attach the mount
adapter to the top as shown in the diagram,
then mount the camera on the mounting
bracket. Make sure that two original screws
are used when mounting the mount adapter;
longer type screws may damage inner components.
t Power Cord (only WV-CP230)
Connect this power cord to an electrical outlet of 120 V AC 60 Hz.
y DC 12 V Input Terminal
(DC 12V IN (only WV-CP232))
This terminal is for connecting the 12 V DC
power supply cord.
u AC 24 V Input Terminal
(AC 24V IN (only WV-CP234))
This terminal is for connecting the 24 V AC
60Hz power supply cord.
i Synchronization Mode Selector
(INT, LL (only WV-CP230 and WV-CP234))
Selects the camera synchronization mode
from internal sync mode (INT) or line-lock
mode (LL).
INT: Sets to internal 2:1 interlace.
LL: Sets to Line-lock mode.
o Automatic Light Control/Electronic Light
Control Selector (ALC , ELC)
Lets you select the mode according to the
lens type that is used with this camera.
ALC: Select this mode when an auto iris lens
(ALC lens) is used with this camera.
ELC: Select this mode when a fixed iris lens
or manual iris lens is used with this camera.
!0 Detail/Aperture Level Selector
(SOFT/SHARP)
The detail/aperture level can be selected with
this selector. Set it to the desired position
while observing the picture on the monitor.
SHARP: Normal position.
SOFT: Select this position when a Quad
System is connected to this camera.
!1 Back Light Compensation Mode Selector
(BLC ON, OFF)
Lets you select the mode according to the
position of the object and light conditions on
the screen.
ON: Select this mode when a strong light
such as a spotlight is in the background.
OFF: Normal picture.
!2 Lens Drive Signal Selector (VIDEO, DC)
Lets you select the mode according to the
type of auto iris lens drive signal to be supplied to the lens from the auto iris lens connector.
VIDEO: Select this mode if you are using a
auto iris lens that requires a video drive
signal.
DC: Select this mode if you are using a auto
iris lens that requires a DC drive signal.
!3 Video Output Connector (VIDEO OUT)
This connector is for connecting with the
VIDEO IN connector of the video monitor.
Whenever the multiplexed vertical drive (VD2)
signal is supplied to this connector, the camera synchronization mode is automatically set
to Vertical Drive.
N1098-0 YWV8QA5102AN Printed in Japan
N 30
Warning:
This equipment generates and uses radio frequency energy and if not installed and used properly,
i.e., in strict accordance with the instruction manual, may cause harmful interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device
pursuant to Subpart J of Part 15 of FCC Rules,
which are designed to provide reasonable protection against such interference when operated in a
commercial environment.
For U.S.A
Copper wire
size (AWG)
Copper wire
size (AWG)
Length
of Cable
(Approx.)
CONNECTIONS
A. WV-CP230 (120V AC 60Hz)
Connect the power cord to an electrical outlet
of 120V AC 60Hz.
B. WV-CP232 (12V DC)
Connect the power cord to the DC 12V IN terminal on the rear panel of the WV-CP232.
Resistance of copper wire [at 20°C (68°F)]
• Calculation of maximum cable length
between camera and power supply :
Resistance
Ω/m
Resistance
Ω/ft
#24
(0.22mm
2
)
0.078
0.026
#22
(0.33mm2)
0.050
0.017
#20
(0.52mm2)
0.03.
0.010
#18
(0.83mm2)
0.018
0.006
10.5V DC ≤ VA − (R x 0.42 x L) ≤ 16V DC
L : Cable length (meters)
R : Resistance of copper wire (Ω/meter)
VA : DC output voltage of power supply unit
VA − 12
L standard = (meters)
0.42 x R
VA − 16
L minimum = (meters)
0.42 x R
VA − 10.5
L maximum = (meters)
0.42 x R
The following adjustment should be made by
qualified service personnel or system installers.
q Loosen the screws on the flange-back adjust-
ing ring.
w Turn the flange-back adjusting ring to the
desired position.
Caution: When the C-mount lens is mounted,
do not rotate the ring counterclockwise
by force after it stops. If the ring is rotated by force, the inner lens or CCD image
sensor may be damaged.
e Tighten the screws on the flange-back adjust-
ing ring.
FOCUS OR FLANGE-BACK ADJUSTMENT
12 V DC
(10.5 V - 16 V)
@
!
C. WV-CP234 (24V AC 60Hz)
Connect the power cable to the AC 24 V IN
terminal on the rear panel of the WV-CP234.
(m)
(ft)
#24
(0.22mm
2
)
95
314
#22
(0.33mm2)
150
495
#20
(0.52mm2)
255
842
#18
(0.83mm2)
425
1 403
Recommended wire gauge sizes for 24 V AC line
24 V AC, 60 Hz
(19.5 V - 28 V)
1 2
Installation of Auto Iris Lens
Connector
Install the lens connector (YFE4191J100) when
using a video drive ALC lens.
The installation should be made by qualified
service personnel or system installers.
Cut the iris control cable at the edge of the lens
connector to remove the existing lens connector
and then remove the outer cable cover of the supplied connector as shown in the diagram.
The pin assignment of the lens connector is as follows:
Pin 1: Power source; +9 V DC, 50 mA max.
Pin 2: Not used
Pin 3: Video signal; 1.3 V[p-p]/40 kΩ
Pin 4: Shield, ground
Pin 3
Pin 4
Pin 2
Rib
Pin 1
Mounting the Lens
Caution:
Before you mount the lens, loosen the two
screws on the ring, and rotate this ring clockwise until it stops. If the ring is not at the end,
the inner glass or CCD image sensor may be
damaged.
q Mount the lens by turning it clockwise on the
lens mount of the camera.
w Connect the lens cable to the auto iris lens
connector on the side of the camera.
Caution for Mounting the Lens
The lens mount should be a C-mount or CS-mount
(1”-32UN) and the lens weight should be less than
450 g (0.99 lbs). If the lens is heavier, both the
lens and camera should be secured by using the
supporter.
The protrusion at the rear of the lens should be as
shown in the diagram.
C-mount: Less than 13 mm (1/2”)
CS-mount: Less than 8 mm (5/16”)
Pick-up Device: 768 (H) x 494 (V) pixels, Interline Transfer CCD
Scanning Area: 4.92 (H) x 3.70 (V) mm (Equivalent to scanning area of 1/3”
pick-up tube)
Synchronization: Internal, Line-locked or Multiplexed vertical drive (VD2),
selectable
Scanning System: 2 : 1 interlace
Scanning: 525 lines / 60 fields / 30 frames
Horizontal: 15.734 kHz
Vertical: 59.94 Hz
Horizontal Resolution: 480 lines
Video Output: 1.0 V[p-p] NTSC composite 75 Ω / BNC connector
Signal-to-Noise Ratio: 50 dB (AGC OFF, weight ON)
Electronic Light Control: Equivalent to continuous variable shutter speed between 1/60 s
and 1/15 000 s
Minimum Illumination: 0.6 lx (0.06 foot-candle) at F0.75 [equivalent to 2.0 lx (0.2 foot-
candle) at F1.4] AGC ON
Detail: SHARP or SOFT, selectable
Lens Mount: C-mount or CS-mount, selectable
Ambient Operating Temperature: −10°C - +50°C (14°F - 122°F)
Ambient Operating Humidity: Less than 90 %
Power Source and WV-CP230: 120 V AC 60 Hz, 3.9 W
Power Consumption: WV-CP232: 12 V DC, 270 mA
WV-CP234: 24 V AC 60 Hz, 3.7 W
Dimensions (without lens): 67 (W) x 65 (H) x 123 (D) mm
[2-5/8” (W) x 2-9/16” (H) x 4-13/16” (D)]
Weights (without lens): WV-CP230: 0.62 kg (1.37 lbs)
WV-CP232: 0.4 kg (0.88 lbs)
WV-CP234: 0.43 kg (0.95 lbs)
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
SPECIFICATIONS
STANDARD ACCESSORIES
Body Cap............................................................................................1 pc.
ALC Lens Connector (YFE4191J100).................................................1 pc.
OPTIONAL ACCESSORIES
Lenses: WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LA210C3, WV-LA408C3, WV-LA908C3,
WV-LZ61/10, WV-LZ62/2, WV-LZ62/8, WV-LF4R5C3A, WV-LF9C3A, WV-LFY3C3,
WV-LFY45C3, WV-LFY9C3
Video Imaging Systems Company
A Division of Panasonic Broadcast & Television Systems Company
A Unit of Matsushita Electric Corporation of America
Executive Office: One Panasonic Way 4H-2, Secaucus, New Jersey 07094
Regional Offices:
Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303
Southeast: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838
Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211
Southwest: 8105 Beltsline Road, Suite 100, Irving, TX 75063 (927) 915-1334
Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010
PANASONIC SALES COMPANY
DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.
San Gabriel Industrial Park, 65th Infantry Ave. KM. 9.5 Carolina, P.R. 00630 (809)750-4300
Solder the lens cable to the pins of the supplied connector.
Flange-back
Adjusting Ring
Flange-back
Adjusting Ring
Screws
Screws
Caution:
To prevent fire or electric shock hazard, UL
listed wire VW-1, style 1007 should be used
for the DC 12 V or AC 24 V Input Terminal.