Panasonic WV-CP232, WV-CP234, WV-CP230 User Manual

1. The following functions are built in. (1) Auto Light Control (ALC)/Electronic Light
Control (ELC)
(2) Automatic Gain Control (AGC) +15 dB
and Automatic Tracing White Balance (ATW)
(3) Camera synchronization mode selec-
FEATURES
2. Minimum illumination of 0.6 lx (0.06 foot-can­dle) at F0.75 (equivalent to 2.0 lx (0.2 foot­candle) at F1.4)
3. Signal-to-noise ratio of 50 dB
4. Horizontal resolution of 480 lines
5. Auto iris lens control selectable between video signal and DC power supply.
1. Do not attempt to disassemble the camera.
To prevent electric shock, do not remove screws or covers. There are no user serviceable parts inside. Ask a qualified service person for servicing.
2. Handle the camera with care.
Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.
3. Do not expose the camera to rain or moisture, or try to operate it in wet areas.
Turn the power off immediately and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock.
4. Do not use strong or abrasive detergents when cleaning the camera body.
Use a dry cloth to clean the camera when dirty. In case the dirt is hard to remove, use a mild detergent and wipe gently.
5. Clean the CCD faceplate with care.
Do not clean the CCD with strong or abrasive detergents. Use lens tissue or a cotton tipped applicator and ethanol.
6. Never face the camera towards the sun.
Do not aim the camera at bright objects. Whether the camera is in use or not, never aim it at the sun or other extremely bright objects. Otherwise, blooming or smear may be caused.
7. Do not operate the camera beyond the specified temperature, humidity or power source ratings.
Use the camera under conditions where tem­perature is between –10°C - +50°C (14°F ­122°F), and humidity is below 90 %. The input power source is 120 V AC 60 Hz for WV-CP230, 12 V DC for WV-CP232, and 24 V AC 60 Hz for WV-CP234.

PRECAUTIONS

Color CCTV Cameras
WV-CP230/WV-CP232/WV-CP234
Before attempting to connect or operate this product,
please read these instructions completely.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte­nance (servicing) instructions in the literature accompanying the appli­ance.
The lightning flash with arrowhead symbol, within an equilateral trian­gle, is interned to alert the user to the presence of uninsulated "dan­gerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
The serial number of this product may be found on the top of the unit. You should note the serial number of this unit in the space provided and retain this instruction as a per­manent record of your purchase to aid identification in the event of theft.
Model No. Serial No.
SA 1966
SA 1965
Caution:
To prevent fire or electric shock hazard, UL listed wire VW-1, style 1007 should be used for the DC 12 V or AC 24 V Input Terminal.
Cautions:
• Connect to 12 V DC (10.5 V-16 V) or 24 V AC (19.5 V-28 V) class 2 power supply only. Make sure to connect the grounding lead to the GND terminal when the power is sup­plied from a 24 V AC power source.
• To prevent fire or electric shock hazard, UL listed wire VW-1, style 1007 should be used for the DC 12 V or AC 24 V Input Terminal.
VIDEO OUT
GND
AC 24V IN
12
VIDEO OUT
<WV-CP230>
<WV-CP234>
<WV-CP232>
DC 12V IN
VIDEO OUT
LL INT ELC ALC
SOFT SHARP
OFF BLC ON DC VIDEO
LL INT ELC ALC
SOFT SHARP
OFF BLC ON DC VIDEO
ELC ALC SOFT SHARP OFF BLC ON
DC VIDEO
WV–
CP230

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

q Auto Iris Lens Connector
Supplies power and control signals to an auto iris lens (not supplied).
w Flange-back Adjusting Ring
This ring adjusts the back-focal distance or picture focus. Rotate this ring clockwise for a C-mount lens or counterclockwise for a CS­mount lens.
e Lens (option)
r Camera Mounting Screw Hole
This hole is for mounting the camera onto a mounting bracket. The camera is originally designed to be mounted from the bottom, but a top-mounting type is also available. To mount from the top, remove the mount adapter from the bottom of the camera by removing two fixing screws. Attach the mount adapter to the top as shown in the diagram, then mount the camera on the mounting bracket. Make sure that two original screws are used when mounting the mount adapter; longer type screws may damage inner com­ponents.
t Power Cord (only WV-CP230)
Connect this power cord to an electrical out­let of 120 V AC 60 Hz.
y DC 12 V Input Terminal
(DC 12V IN (only WV-CP232))
This terminal is for connecting the 12 V DC power supply cord.
u AC 24 V Input Terminal
(AC 24V IN (only WV-CP234))
This terminal is for connecting the 24 V AC 60Hz power supply cord.
i Synchronization Mode Selector
(INT, LL (only WV-CP230 and WV-CP234))
Selects the camera synchronization mode from internal sync mode (INT) or line-lock mode (LL).
INT: Sets to internal 2:1 interlace. LL: Sets to Line-lock mode.
o Automatic Light Control/Electronic Light
Control Selector (ALC , ELC)
Lets you select the mode according to the lens type that is used with this camera. ALC: Select this mode when an auto iris lens
(ALC lens) is used with this camera.
ELC: Select this mode when a fixed iris lens
or manual iris lens is used with this cam­era.
!0 Detail/Aperture Level Selector
(SOFT/SHARP)
The detail/aperture level can be selected with this selector. Set it to the desired position while observing the picture on the monitor.
SHARP: Normal position. SOFT: Select this position when a Quad
System is connected to this camera.
!1 Back Light Compensation Mode Selector
(BLC ON, OFF)
Lets you select the mode according to the position of the object and light conditions on the screen. ON: Select this mode when a strong light
such as a spotlight is in the background.
OFF: Normal picture.
!2 Lens Drive Signal Selector (VIDEO, DC)
Lets you select the mode according to the type of auto iris lens drive signal to be sup­plied to the lens from the auto iris lens con­nector. VIDEO: Select this mode if you are using a
auto iris lens that requires a video drive signal.
DC: Select this mode if you are using a auto
iris lens that requires a DC drive signal.
!3 Video Output Connector (VIDEO OUT)
This connector is for connecting with the VIDEO IN connector of the video monitor. Whenever the multiplexed vertical drive (VD2) signal is supplied to this connector, the cam­era synchronization mode is automatically set to Vertical Drive.
N1098-0 YWV8QA5102AN Printed in Japan
N 30
Warning: This equipment generates and uses radio frequen­cy energy and if not installed and used properly, i.e., in strict accordance with the instruction manu­al, may cause harmful interference to radio com­munications. It has been tested and found to com­ply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protec­tion against such interference when operated in a commercial environment.
For U.S.A
Copper wire size (AWG)
Copper wire size (AWG)
Length of Cable (Approx.)

CONNECTIONS

A. WV-CP230 (120V AC 60Hz)

Connect the power cord to an electrical outlet of 120V AC 60Hz.

B. WV-CP232 (12V DC)

Connect the power cord to the DC 12V IN ter­minal on the rear panel of the WV-CP232.
Resistance of copper wire [at 20°C (68°F)]
• Calculation of maximum cable length between camera and power supply :
Resistance
/m Resistance
/ft
#24
(0.22mm
2
)
0.078
0.026
#22
(0.33mm2)
0.050
0.017
#20
(0.52mm2)
0.03.
0.010
#18
(0.83mm2)
0.018
0.006
10.5V DC ≤ VA (R x 0.42 x L) 16V DC L : Cable length (meters) R : Resistance of copper wire (/meter) VA : DC output voltage of power supply unit
VA 12
L standard = (meters)
0.42 x R VA 16
L minimum = (meters)
0.42 x R
VA 10.5
L maximum = (meters)
0.42 x R
The following adjustment should be made by qualified service personnel or system installers.
q Loosen the screws on the flange-back adjust-
ing ring.
w Turn the flange-back adjusting ring to the
desired position.
Caution: When the C-mount lens is mounted,
do not rotate the ring counterclockwise by force after it stops. If the ring is rotat­ed by force, the inner lens or CCD image sensor may be damaged.
e Tighten the screws on the flange-back adjust-
ing ring.
FOCUS OR FLANGE-BACK ADJUSTMENT
12 V DC
(10.5 V - 16 V)
@
!

C. WV-CP234 (24V AC 60Hz)

Connect the power cable to the AC 24 V IN terminal on the rear panel of the WV-CP234.
(m)
(ft)
#24
(0.22mm
2
)
95
314
#22
(0.33mm2)
150
495
#20
(0.52mm2)
255
842
#18
(0.83mm2)
425
1 403
Recommended wire gauge sizes for 24 V AC line
24 V AC, 60 Hz
(19.5 V - 28 V)
1 2
Installation of Auto Iris Lens
Connector
Install the lens connector (YFE4191J100) when using a video drive ALC lens.
The installation should be made by qualified service personnel or system installers.
Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover of the sup­plied connector as shown in the diagram. The pin assignment of the lens connector is as fol­lows:
Pin 1: Power source; +9 V DC, 50 mA max. Pin 2: Not used Pin 3: Video signal; 1.3 V[p-p]/40 k Pin 4: Shield, ground
Pin 3
Pin 4
Pin 2
Rib
Pin 1

Mounting the Lens

Caution:
Before you mount the lens, loosen the two screws on the ring, and rotate this ring clock­wise until it stops. If the ring is not at the end, the inner glass or CCD image sensor may be damaged.
q Mount the lens by turning it clockwise on the
lens mount of the camera.
w Connect the lens cable to the auto iris lens
connector on the side of the camera.
q
w

Caution for Mounting the Lens

The lens mount should be a C-mount or CS-mount (1”-32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the
lens and camera should be secured by using the supporter. The protrusion at the rear of the lens should be as shown in the diagram.
C-mount: Less than 13 mm (1/2”)
CS-mount: Less than 8 mm (5/16”)
qe
w
Pick-up Device: 768 (H) x 494 (V) pixels, Interline Transfer CCD Scanning Area: 4.92 (H) x 3.70 (V) mm (Equivalent to scanning area of 1/3”
pick-up tube)
Synchronization: Internal, Line-locked or Multiplexed vertical drive (VD2),
selectable Scanning System: 2 : 1 interlace Scanning: 525 lines / 60 fields / 30 frames
Horizontal: 15.734 kHz
Vertical: 59.94 Hz Horizontal Resolution: 480 lines Video Output: 1.0 V[p-p] NTSC composite 75 Ω / BNC connector Signal-to-Noise Ratio: 50 dB (AGC OFF, weight ON) Electronic Light Control: Equivalent to continuous variable shutter speed between 1/60 s
and 1/15 000 s
Minimum Illumination: 0.6 lx (0.06 foot-candle) at F0.75 [equivalent to 2.0 lx (0.2 foot-
candle) at F1.4] AGC ON Detail: SHARP or SOFT, selectable Lens Mount: C-mount or CS-mount, selectable Ambient Operating Temperature: 10°C - +50°C (14°F - 122°F) Ambient Operating Humidity: Less than 90 % Power Source and WV-CP230: 120 V AC 60 Hz, 3.9 W
Power Consumption: WV-CP232: 12 V DC, 270 mA
WV-CP234: 24 V AC 60 Hz, 3.7 W
Dimensions (without lens): 67 (W) x 65 (H) x 123 (D) mm
[2-5/8” (W) x 2-9/16” (H) x 4-13/16” (D)] Weights (without lens): WV-CP230: 0.62 kg (1.37 lbs)
WV-CP232: 0.4 kg (0.88 lbs)
WV-CP234: 0.43 kg (0.95 lbs)
Weights and dimensions indicated are approximate. Specifications are subject to change without notice.

SPECIFICATIONS

STANDARD ACCESSORIES

Body Cap............................................................................................1 pc.
ALC Lens Connector (YFE4191J100).................................................1 pc.

OPTIONAL ACCESSORIES

Lenses: WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LA210C3, WV-LA408C3, WV-LA908C3,
WV-LZ61/10, WV-LZ62/2, WV-LZ62/8, WV-LF4R5C3A, WV-LF9C3A, WV-LFY3C3, WV-LFY45C3, WV-LFY9C3
Video Imaging Systems Company
A Division of Panasonic Broadcast & Television Systems Company A Unit of Matsushita Electric Corporation of America
Executive Office: One Panasonic Way 4H-2, Secaucus, New Jersey 07094 Regional Offices:
Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southeast: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Southwest: 8105 Beltsline Road, Suite 100, Irving, TX 75063 (927) 915-1334 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010
PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.
San Gabriel Industrial Park, 65th Infantry Ave. KM. 9.5 Carolina, P.R. 00630 (809)750-4300
Solder the lens cable to the pins of the sup­plied connector.
Flange-back Adjusting Ring
Flange-back Adjusting Ring
Screws
Screws
Caution:
To prevent fire or electric shock hazard, UL listed wire VW-1, style 1007 should be used for the DC 12 V or AC 24 V Input Terminal.