Panasonic S-200PE2R5, U-200PE1R8 Operating Instructions Manual

Operating Instructions
Air Conditioner
High Static Pressure Ducted
(Type E2)
Model No.
INDOOR UNIT
S-200PE2R5
(Type E2)
OUTDOOR UNIT
Heat Pump Unit
U-200PE1R8
(3-phase)
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
85464609316020
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
CV6233318783
Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached.
Contents
Safety Precautions ........................................................... 2
Precautions for Use ......................................................... 4
Names of Parts ................................................................. 5
Operation .......................................................................... 6
• Operation Mechanism ................................................... 6
Maintenance ..................................................................... 7
• Before Requesting Services ......................................... 7
Troubleshooting ............................................................... 8
Specications ................................................................... 9
• Indoor unit / Outdoor unit ............................................. 9
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the lid of the electrical component box.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
WARNING
Conrm to authorized dealer or specialist on usage of specied refrigerant type. Using of refrigerant other than the specied type may cause product damage, burst and injury etc.
This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
Never use or store gasoline or other ammable vapor or liquid near the air conditioner — it is very dangerous.
Do not use this appliance in a potentially explosive atmosphere.
Never touch the unit with wet hands. Do not insert your ngers or
other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
This symbol refers to a hazard or
WARNING
CAUTION
Prohibited matters
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difculties or problems, consult your dealer for help.
• This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
2
unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
Matters to be observed
If the refrigerant comes in contact with a ame, it produces a toxic gas.
For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.
CAUTION
Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line.
Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the xed wiring in accordance with the wiring rules.
To prevent possible hazards from insulation failure, the unit must be grounded.
Do not use modied cord, joint cord, extension cord or unspecied cord to prevent overheating and re.
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/re/electric shock)
Examples of abnormality/failure:
• The ELCB trips frequently.
• The product sometimes does not start when turned on.
• The power is sometimes disconnected when the cord is moved.
• Burnt odor or abnormal noise is detected during operation.
• The body is deformed or abnormally hot.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that do not play with the appliance.
Keep the re alarm and the air outlet at least 1.5m away from the unit.
Do not cool or heat the room too much if babies or invalids are present.
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum ns of the outdoor unit. You may get injured.
Do not sit or step on the unit. You may fall down accidentally.
Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.
NOTICE
• The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
Important Information Regarding The Refrigerant Used
This product contains uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
(1)
GWP
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
3
Precautions for Use
Installation
This air conditioner must be installed properly by qualied
installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric
supply in your home or ofce is the same as the voltage shown on the nameplate.
WARNING
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
Also locations of extremely high temperature such as a greenhouse. Locations where excessively high heat-generating
objects are placed.
Attention:
Avoid installing the outdoor unit where salty sea water can
splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)
Wiring
All wiring must conform to the local electrical codes.
(Consult your dealer or a qualied electrician for details.) Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring. Wiring must be done by a qualied electrician.
Operation Condition
Use this air conditioner under the following temperature range.
Indoor temperature range:
Cooling mode 18°C ~ 32°C (*DBT) Heating mode 16°C ~ 30°C (*DBT)
Outdoor temperature range:
Cooling mode -10°C ~ 46°C (*DBT) Heating mode -25°C ~ 15°C (*WBT)
*DBT: Dry bulb temperature *WBT: Wet bulb temperature
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Pb
Operation Preparation
Turn the power mains on 5 hours before the start of operation.
(For warm-up)
Leave the power mains ON for continuous use.
NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.
Tips for Energy Saving
Avoid
Do not block the air intake and outlet of the unit.
(If either is obstructed, the unit will not function well, causing malfunction.)
During cooling operation, use sunshades, blinds or cur-
tains to prevent direct sunlight from entering the room.
Do
Always keep the air lter clean.
(A clogged lter will impair the performance of the unit.) → “Maintenance” (P.7) To prevent conditioned air from escaping, keep win-
dows, doors and any other openings closed.
ON
4
Loading...
+ 8 hidden pages