OUTDOOR UNIT
Single Split (Single-phase)
Type PZH2
U-71PZH2R5
U-100PZH2R5
U-125PZH2R5
U-140PZH2R5
Operating Instructions
Air Conditioner
Single Split (3-phase)
Type PZH2
U-100PZH2R8
U-125PZH2R8
U-140PZH2R8
●
Connectable indoor unit lineup
This booklet is the operating instructions for outdoor unit. Regarding the indoor unit, see the
operating instructions supplied with the indoor unit.
INDOOR UNIT
4-Way Cassette
Wall-Mounted
Ceiling
Low Silhouette Ducted
Ducted
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
ACXF55-22950
Thank you for purchasing this Panasonic product.
This product is a commercial air conditioner outdoor unit.
Installation Instructions attached.
Contents
Safety Precautions
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel or
the appliance:
Safety Precautions ........................................................... 2
z
Precautions for Use .........................................................5
z
Names of Parts ................................................................. 6
z
Specications ................................................................... 7
z
•Outdoor unit ...................................................................7
This symbol shows that this equipment
uses a flammable refrigerant. If the
WARNING
CAUTION
CAUTION
CAUTION
refrigerant is leaked, together with
an external ignition source, there is a
possibility of ignition.
This symbol shows type of flammable
refrigerant contained in the system.
This symbol shows that a service
personnel should be handling this
equipment with reference to the
Technical Manual.
This symbol shows that there is
information included in the Operating
Instructions and/or Installation Instructions.
Product Information
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model and
serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
Important Information Regarding The
Refrigerant Used
This product contains uorinated greenhouse gases. Do
not vent gases into the atmosphere.
Refrigerant type: R32
(1)
GWP
(1)
Periodical inspections for refrigerant leaks may be
required depending on European or local legislation.
Please contact your local dealer for more information.
value: 675
GWP = global warming potential
This symbol refers to a hazard or
WARNING
CAUTION
Prohibited matters
• Read these Operating Instructions carefully before using this
air conditioner. If you still have any difculties or problems,
consult your dealer for help.
• This air conditioner is designed to give you comfortable
room conditions. Use this only for its intended purpose as
described in these Operating Instructions.
unsafe practice which can result in
severe personal injury or death.
This symbol refers to a hazard or
unsafe practice which can result
in personal injury or product or
property damage.
Matters to be
observed
WARNING
Conrm to authorized dealer
or specialist on usage of
specied refrigerant type. Using
of refrigerant other than the
specied type may cause product
damage, burst and injury etc.
This air conditioner has no
ventilator for intaking fresh air
from outdoors. You must open
doors or windows frequently
when you use gas or oil heating
appliances in the same room,
which consume a lot of oxygen
from the air.
Otherwise there is a risk of
suffocation in an extreme case.
Never use or store gasoline or
other ammable vapor or liquid
near the air conditioner — it is
very dangerous.
Do not use this appliance in a
potentially explosive atmosphere.
Never touch the unit with wet
hands.
Do not insert your ngers or
other objects into the air
conditioner indoor or
outdoor unit, rotating parts may
cause injury.
2
WARNING
If the refrigerant comes in contact
with a ame, it produces a toxic
gas.
For safety, be sure to turn the
air conditioner off and also to
disconnect the power before
cleaning or servicing.
Pull off the power plug from
a receptacle, or switch off
the breaker, or switch off
the power disconnecting mean to
isolate the air conditioner from the
main power supply in case of
emergency.
Dispose of according to national
and/or local legislation.
This product must not be modied
or disassembled under any
circumstances.
Modied or disassembled unit
may cause re, electric shock or
injury.
Do not clean inside the indoor and
outdoor units by users. Engage
authorized dealer or specialist for
cleaning.
In case of malfunction of this
appliance, do not repair by yourself.
Contact the sales dealer or service
dealer for a repair and disposal.
Provide a power outlet to be used
exclusively for each unit, and a
power supply disconnect, Earth
Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD)
for overcurrent protection should
be provided in the exclusive line.
Provide a power outlet
exclusively for each unit, and full
disconnection means having a
contact separation in all poles
must be incorporated in the xed
wiring in accordance with the
wiring rules.
Do not use modied
cord, joint cord,
extension cord or
unspecied cord to prevent
overheating and re.
The appliance shall be stored
in a room without continuously
operating ignition sources (for
example: open ames, an
operating gas appliance or an
operating electric heater).
Be aware that refrigerants may
not contain an odour.
An unventilated area where
the appliance using ammable
refrigerants is installed shall be
so constructed that should any
refrigerant leak, it will not stagnate
so as to create a re or explosion
hazard.
The appliance shall be stored
in a well-ventilated area where
the room size corresponds to
the room area as specied for
operation.
After the unit is installed, never
fail to ask the installer for the oor
space of the room where the unit
is installed and the refrigerant
charge amount.
In case the unit or the room
divider is changed, never fail to
consult the sales dealer or service
dealer.
Do not use means to accelerate
the defrosting process or to clean,
other than those recommended
by the manufacturer.
Do not pierce or burn.
In cases that require mechanical
ventilation, ventilation openings
shall be kept clear of obstruction.
To prevent possible hazards
from insulation failure, the
unit must be grounded.