Panasonic U-71PZH2R5, U-100PZH2R5, U-125PZH2R5, U-140PZH2R5, U-100PZH2R8 Operating Instructions

...
Type 71 Type 100, 125, 140
Model No.
OUTDOOR UNIT
Single Split (Single-phase) Type PZH2
U-71PZH2R5 U-100PZH2R5 U-125PZH2R5
U-140PZH2R5
Operating Instructions
Air Conditioner
U-100PZH2R8 U-125PZH2R8 U-140PZH2R8
Connectable indoor unit lineup
This booklet is the operating instructions for outdoor unit. Regarding the indoor unit, see the operating instructions supplied with the indoor unit.
INDOOR UNIT
4-Way Cassette Wall-Mounted
Ceiling
Low Silhouette Ducted Ducted
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
ACXF55-22950
Thank you for purchasing this Panasonic product. This product is a commercial air conditioner outdoor unit. Installation Instructions attached.
Contents
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
Safety Precautions ........................................................... 2
z
Precautions for Use .........................................................5
z
Names of Parts ................................................................. 6
z
Specications ................................................................... 7
z
•Outdoor unit ...................................................................7
This symbol shows that this equipment uses a flammable refrigerant. If the
WARNING
CAUTION
CAUTION
CAUTION
refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
This symbol shows type of flammable refrigerant contained in the system.
This symbol shows that a service personnel should be handling this equipment with reference to the Technical Manual.
This symbol shows that there is information included in the Operating Instructions and/or Installation Instructions.
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
Important Information Regarding The Refrigerant Used
This product contains uorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type: R32
(1)
GWP
(1)
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
value: 675
GWP = global warming potential
This symbol refers to a hazard or
WARNING
CAUTION
Prohibited matters
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difculties or problems, consult your dealer for help.
• This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
Matters to be observed
WARNING
Conrm to authorized dealer or specialist on usage of specied refrigerant type. Using of refrigerant other than the specied type may cause product damage, burst and injury etc.
This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
Never use or store gasoline or other ammable vapor or liquid near the air conditioner — it is very dangerous.
Do not use this appliance in a potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
2
WARNING
If the refrigerant comes in contact with a ame, it produces a toxic gas.
For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
Dispose of according to national and/or local legislation.
This product must not be modied or disassembled under any circumstances. Modied or disassembled unit may cause re, electric shock or injury.
Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair and disposal.
Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line.
Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the xed wiring in accordance with the wiring rules.
Do not use modied cord, joint cord, extension cord or unspecied cord to prevent overheating and re.
The appliance shall be stored in a room without continuously operating ignition sources (for example: open ames, an operating gas appliance or an operating electric heater).
Be aware that refrigerants may not contain an odour.
An unventilated area where the appliance using ammable refrigerants is installed shall be so constructed that should any refrigerant leak, it will not stagnate so as to create a re or explosion hazard.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specied for operation.
After the unit is installed, never fail to ask the installer for the oor space of the room where the unit is installed and the refrigerant charge amount.
In case the unit or the room divider is changed, never fail to consult the sales dealer or service dealer.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
Do not pierce or burn. In cases that require mechanical
ventilation, ventilation openings shall be kept clear of obstruction.
To prevent possible hazards from insulation failure, the unit must be grounded.
3
Loading...
+ 5 hidden pages