15 Exploded View and Replacement Parts List----------117
15.1. Exploded View and Mechanical Replacement
Parts List--------------------------------------------------117
15.2. Electrical Replacement Parts List ------------------117
2
TH-58PF12UK
1Safety Precautions
1.1.General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. Wh en wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. Wh en conducting repairs and servicing, do not twist the Faston connec tors but plug them straight in or unplug them straight
out.
4. Wh en servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overhe ated or
damaged by the short circuit.
5. After servicing, see to it that all the protective device s such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage curre nt checks to prevent the customer from being exposed to shock hazards.
1.1.1.Leakage Current Cold Check
1. Unplug the AC cord and co nnect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading
should be between 1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be.
Figure 1
1.1.2.Leakage Current Hot Check (See
Figure 1 .)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15µF capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1 .
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
3
TH-58PF12UK
2Warning
2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices , place the asse mbly on a conductive surfac e such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as “anti-static (ESD protected)” can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precaution s.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise ham less motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient
to damage an ES device).
4
TH-58PF12UK
2.2.About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol PbF stamped on the back of PCB.
Caution
• Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher. Please
use a high temperature soldering iron and set it to 700 ± 20 °F (370 ± 10 °C).
• Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
• After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto the
opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder. However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
5
TH-58PF12UK
3Service Navigation
3.1.Service Hint
Board NameFunctionBoard NameFunction
DNDigital Signal Processor, MicrocomputerSSSustain drive
DFormat Converter, Plasma AI Processor
Sub-Field Processor
DS Slot Interface (Audio / Video / Sync Input Switch),
Sync Processor, Audio Processor,
Speaker Out Amplifier, DC-DC Converter
SCScan driveV1Remote receiver, LED-G, R
SUScan out (Upper)
Non serviceable.
SU-Board should be exchanged for service.
SDScan out (Lower)
Non serviceable.
SD-Board should be exchanged for service.
Horizontal scanning frequency 15 - 110 kHz
Vertical scanning frequency 48 - 120 Hz
P
/B (BNC), PR/R (BNC)0.7 Vp-p (75-ohm)
B
AUDIO IN (RCA PIN JACK × 2)0.5 Vrms
Y or G without sync 0.7 Vp-p (75-ohm)
B / P
/ CB: 0.7 Vp-p (75-ohm)
B
/ CR: 0.7 Vp-p (75-ohm)
R / P
R
HD / VD: 1.0 - 5.0 Vp-p (high impedance)
AUDIO IN (M3 JACK)0.5 Vrms
TH-58PF12UK
9
TH-58PF12UK
5Operating Instructions
10
TH-58PF12UK
Option Menu for GPF12D series
GPF12D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful
for special function required customers. This should be set at the installation stage.
Option menusdefault settingContents
Weekly Command Timer---Sets Weekly Command Timer.
Onscreen displayOnEnable/Disable to display input mode indication after power on and no signal
Initial INPUTOffSets the initial input mode when the power is turned on. Allow input mode selec-
Initial VOL levelOffSets the initial volume level when the power is turned on. Allow Volume control
Maximum VOL LevelOffSets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lockOffFixes the input mode to AV, Component/RGB or PC. Can not change input
Off-timer functionEnableOff-timer operation Enable/Disable.
Initial Power ModeNormalSets the power mode of the unit for when the power recovers from failure or
ID select0Set ID number from 0 to 100.
Remote IDOffRemote ID function On/Off.
Serial IDOffSerial ID function On/O ff
Display sizeOffDisplay size function On/Off
Studio W/BOffStudio W/B function On/Off
Studio GainOffStudio Gain function On/Off
Slot powerOffSets the slot power mode while the power is turned on.
Power On Screen DelayOffYou can set the power-on delay time of the displays to reduce the power load,
Clock DisplayOffClock Display function On/Off.
All AspectDefaultAspect mode: default/All aspect mode.
Auto SetupManualSets the operational mode of the automatic position adjustment in the POS./
RotateOffRotate function On/Off
Serial Slot SelectSlot2Selects the slot which communicates serial.
indication.
tion while power is on.
while power is on.
mode by input selection key.
down)
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Surround, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
after plugging off and in again.
(While the Remote ID on, standard remote function can not control the unit.)
Allow Optional Terminal Board insert Slots while power is on.
when you press to turn on the multiple displays that are set together, for
example, on MULTI DISPLAY system.
Set each display’s setting individually.
SIZE memu.
Note: The setting of an external command can be set only from the fixed serial
terminal.
Note:
When both main unit buttons and remote control are disabled due to the “Button lo ck”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
11
TH-58PF12UK
6Service Mode
6.1.CAT (Computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
6.1.1.IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
12
TH-58PF12UK
6.1.2.CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
Memory data change
To exit the CD mode, press the R button on the remote control.
6.1.3.SD mode
Select the SD mode by Up/Down button on the remote control at the front page of CA T mode and then press the Action button on
the remote control.
To exit the SD mode, press the R button on the remote control.
13
TH-58PF12UK
6.1.4.MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of DN-Board.
Destination number
NumberDestinationNumberDestination
0Japan16-1North America17-2Europe18China
3Others19China (Hotel)
4Britain20Russia
5Taiwan21Russia (Hotel)
6Thailand22Hong Kong
7-- 23-8Japan (Hotel)24-9North America (Hotel)25--
10Europe (Hotel)26--
11--27-12Britain (Hotel)28Middle East/Hong Kong
13--29Middle East/Hong Kong (Hotel)
14Thailand (Hotel)30Australia
15--31Australia (Hotel)
Default setting
NumberDestination
1North America
6.1.5.ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.
14
6.2.IIC mode structure (following items value is sample data)
TH-58PF12UK
15
TH-58PF12UK
7Troubleshooting Guide
7.1.Self Check
7.1.1.Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the volume down
button on the customer controls at the bottom of the set,
at the same time pressing the OFF-TIMER button on the
remote control, and the screen will show.
If the IIC ports have been checked and found to be incorrect
Or not located then “ - - ” will appear in place of “ OK ”
“ 01 ” in the line of the “ PTCT ” means the number of blinks of
the Power LED is 1. (Reference to 7.1.2)
“ H09 ” in the line of the “ PTCT ” is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the “ PTCT ” displays when you get into the Selfcheck mode for the first time only after the Power LED
blinks.
16
TH-58PF12UK
7.1.2.Power LED Blinking timing chart
1. Subject
Information of LED Blinking timing chart.
2. Contents
When an abnormality has occurred to the unit, the protection circuit operates and resets to the stand by mode. At this time,
the defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
* Refer to 7.1.1 Display Indication
About blinking LED
17
TH-58PF12UK
7.2.No Power
First check point
There are following 3 states of No Power indication by power LED.
1. No lit.
2. Green is lit then turns red blinking a few seconds later.
3. Only red is lit.
7.3.No Picture
18
7.4.Local screen failure
Plasma display may have local area failure on the screen. Fig - 1 is the possible defect P.C.B. for each local area.
TH-58PF12UK
Fig - 1
19
TH-58PF12UK
8Service Fixture & Tools
8.1.SC jig
Purpose:
To find the failure board (SC or SU/SD) when the power LED is blinking 7 times.
SC jig:
Jumper connector to connect to SC50 connector on SC board
Part number:
TZSC09187
How to use:
Caution: Remove SC jig from SC board after inspection.
1. Remove all connector between SC board and SU/SD board to isolate SC board from both SU and SD board electrically.
Note: The board will be damaged if all connector is not removed (for example; remove connector only for SU board
and stay connecting with SD board. The boad will be damaged.)
2. Connect SC jig to connector SC51 at left bottom side of SC board.
3. Turn on the TV/Display Unit and confirm the power LED blinking.
LED blinking: Possible cause of failure is in SC board
No LED blinking (Lighting or no lighting): Possible cause of failure is in SU or SD board
4. After inspection, turn off the TV/Display Unit and wait a few minutes to discharge.
5. Remove SC jig from SC board.
Remark: This SC jig can be used for all 2009 Plasma TV and Plasma Display.
20
TH-58PF12UK
9Disassembly and Assem-
bly Instructions
• To disassemble P.C.B., wait for 1 minute after power was off
for discharge from electrolysis capacitors.
•, , and marks indicate screw positions.
9.1.Removal of Rear Cover
1. Remove screws (×12 , ×27 ) and then remove the
Rear Cover.
Note: when fixing the Rear Cover
• Screw on screws (*1) firstly by lifting the bottom of the
Rear Cover.
9.3.Removal of HA-Board
1. Remove 4 screws (D) and then remove the HA Terminal
Block.
2. Remove 4 screws (E).
3. Remove 3 screws (F) and then remove HA-Board.
9.4.Removal of Slot Block
1. Remove the flexible cables from the connectors (DS1,
DS3).
2. Disconnect the connectors (DS2, DS4, DS6, DS7, DS8,
DS15).
9.2.Removal of HHH-Board
1. Remove 4 screws (A) and then remove the HHH Terminal
Block.
2. Remove 4 screws (B).
3. Remove 4 screws (C) and then remove HHH-Board.
3. Remove 6 screws and then remove the Slot Block.
21
TH-58PF12UK
9.5.Removal of HX-Board
1. Remove the HHH Terminal Block and the HA Terminal
Block.
(Refer to Removal of HHH-Board and HA-Board)
2. Remove 1 screw( ) and then remove the Slot Cover.
3. Remove 6 screws( ) and then remove the Slot Cover.
4. Disconnect the connector (HX1).
5. Remov e 4 Hexagonal-Head screws and 2 screws of HXBoard and then remove HX-Board.
9.6.Removal of DS-Board
1. Remove the HHH Terminal Block and the HA Terminal
Block.
(Refer to Removal of HHH-Board and HA-Board)
2. Remove the Slot Cover.
(Refer to Removal of HX-Board)
3. Disconnect the connector (DS14).
4. Remove 10 screws and then remove the Fixed Plate.
5. Remove the flexible cables from the connectors (DS1,
DS3).
6. Disconnect the connectors (DS2, DS4, DS6, DS7, DS8,
DS15).