Power Source220-240 VAC, 50/60Hz
Power Consumption
Power on250 W (37 inch)280 W (42 inch)
Stand-byconditionSave OFF 0.8 W, Save ON 0.6 W (37 inch)Save OFF 0.8 W, Save ON 0.6 W (42 inch)
Power off condition0.2 W (37 inch)0.2 W (42 inch)
Plasma DisplaypanelDrive method:AC type 37-inch,Drive method:AC type 42-inch,
16:9 aspect ratio (37 inch)16:9 aspect ratio (42 inch)
Contrast RatioMax10000:1
Screen size818 mm (W) × 461 mm (H) × 939 mm (diagonal) (37 inch)
920 mm (W) × 518 mm (H) × 1,056 mm (diagonal) (42 inch)
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screw heads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1MΩ and 5.2MΩ.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5kΩ, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
5
TH-37PG9W / TH-42PG9W
3 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise hamless motion such as the brushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
6
TH-37PG9W / TH-42PG9W
4 About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol
Caution
· Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher.
Please use a high temperature soldering iron and set it to 700 ± 20 °F (370 ± 10 °C).
· Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
· After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto
the opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder.
However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
stamped on the back of PCB.
7
TH-37PG9W / TH-42PG9W
5 Service Hint
Note:
·The remote control transmitter is not included with this set.
·Execute by the following remote control transmitter when repairing.
product number : EUR7636070R
Board NameFunction
DADigital Signal Processor, Micon
DFormat Converter, Plasma AI Processor
JSlot Interface (Audio / Video / Sync input
SSSustain drive
SCScan drive
SUScan out (Upper)
SDScan out (Lower)
C1Data Drive (Right)
C2Data Drive (Left)
SPSpeaker
SPower switch
KRemote receiver, LED_G,R
GKKey switch
PPower supply
HXPC / RS-232C_Input terminal
HABNC Component Video
Sub-Field Processor
Switch),
SYNC processor, Sound processor,
Note:
· Extension cable kit Slot Board is supplied as service fixtures and tools.
(Parts No. TZCS07040)
8
6 Disassembly
· To disassemble P.C.B., wait for 1 minute after power was
off for discharge from electrolysis capacitors.
andmarks indicate screw positions.
·
6.1. Removal of the Back Cover
1. Remove the screws (×6,×6 , ×14,×8 ) and then
remove the Back Cover.
TH-37PG9W / TH-42PG9W
6.2. Removal of the HA-Board
1. Remove the 4 screws(D) and then remove the HA Terminal
Block.
2. Remove the 4 screws(E).
3. Remove the 2 screws(F) and then remove the HA-Board.
2. Remove the 6 screws and then remove the P-Board.
6.9. Removal of the Speaker (L, R)
6.9.1. Removal of the Speaker (L)
1. Disconnect the coupler (J8).
2. Remove the 2 screws (
3. Remove the 4 screws (
) and then remove the Plate.
) and then remove the Speaker (L).
11
TH-37PG9W / TH-42PG9W
6.9.2. Removal of the Speaker (R)
1. Disconnect the coupler (J7).
2. Remove the 2 screws (
3. Remove the 4 screws (
) and then remove the Plate.
) and then remove the Speaker (R).
6.10. Removal of the SU-Board and
the SD-Board
1. Remove the each 2 screws.
2. Remove the Flexible Cable from the couplers(SU1, SU2,
SU3).
3. Remove the Flexible Cable from the couplers(SD1, SD2,
SD3).
4. Disconnect the couplers(SU45, SD46).
5. Slide the SU-Board and the SD-Board to the left, remove
the SU-Board and the SD-Board from the couplers(SC41,
SC42).
6.11. Removal of the SC-Board
1. Slide the SU-Board and the SD-Board to the left.
(Reference to Removal of the SU-Board and the SD-Board)
2. Disconnect the couplers(SC2, SC20, SC23).
3. Remove the 6 screws and then remove the SC-Board.
12
TH-37PG9W / TH-42PG9W
6.12. Removal of the SS-Board
1. Disconnect the couplers(SS11, SS12, SS23, SS34).
2. Remove the Flexible Cable from the couplers(SS41, SS42,
SS43, SS44)
3. Remove the 6 screws and then remove the SS-Board.
6.13. Removal of the C1, C2-Board
1. Remove the Slot Block.
(Reference to Removal of the Slot Block)
2. Remove the each 6 screws and then remove the Stand
Blocks.
6.13.1. Removal of the C1-Board
1. Disconnect the couplers(C11, C12).
2. Remove the 6 screws and then remove the Flexible Cable
from the couplers(CB1, CB2, CB3).
3. Remove the 3 screws and then remove the C1-Board.
6.13.2. Removal of the C2-Board
1. Disconnect the coupler(C21, C22).
2. Remove the 8 screws and then remove the Flexible Cable
from the couplers(CB4, CB5 CB6, CB7).
3. Remove the 4 screws and then remove the C2-Board.
13
TH-37PG9W / TH-42PG9W
6.14. Removal of the S-Board
1. Disconnect the coupler(SS34).
2. Remove the 2 screws(A) and then remove the S-Board
Block.
3. Disconnect the coupler(S1).
4. Remove the 2 screw(B) and then remove the S-Board.
6.15. Removal of the GK-Board
1. Remove the 2 screws(C) and then remove the Plate(A).
2. Remove the 2 screws(D).
3. Disconnect the coupler(GK3) and then remove the GKBoard.
6.16. Removal of the K-Board
1. Remove the 2 screws.
2. Disconnect the coupler(K1) and then remove the K-Board.
14
TH-37PG9W / TH-42PG9W
6.17. Removal of the Control Panel,
the Power SW and the Door
1. Remove the S-Board Block.
(Remove to the Removal of the S-Board)
2. Remove the K-Board.
(Remove to the Removal of the K-Board)
3. Remove the GK-Board.
(Remove to the Removal of the GK-Board)
4. Remove the 5 screws(E) and then remove the Plate(B).
5. Remove the 2 screws(F) and then remove the Control
Panel.
6.18. Removal of the Front Glass
1. Disconnect the couplers(J2, J7, J8, J15, SS34).
2. Remove the 10 screws.
3. Pull the bottom of the Plasma Panel forward (arrow1).
4. Slide the Plasma Panel and then remove the Plasma Panel
(arrow2).
6. Remove the 1 screw(G) and then remove the Spring.
7. Remove the 3 hooks and then remove the Door.
8. Remove the 4 hooks and then remove the Power SW.
5. Remove the 5 screws (E) and then remove the Plate (B).
6. Remove the each screws and then remove the Glass Fixed
Plate (A, B, C, D).
7. Remove the Front Glass.
15
TH-37PG9W / TH-42PG9W
· TH-42PG9W
Removed number of screws: 25
· TH-37PG9W
Removed number of screws: 23
6.19. Removal of the Escutcheon
1. Disconnect the couplers(J2, J7, J8, J15, SS34).
2. Remove the 10 screws.
3. Lift up the bottom of the Plasma Panel in the direction of the
arrow1 and pull the Plasma Panel in the direction of the
arrow2 and then remove the Plasma Panel.
Note: when Front Glass is exchanged
· Each Front Glass Sponge must be stuck along the
edge of Fixed Angle.
Note
· The sponges are parts which cannot be recycled.
Please use the new article when you exchange the
Front Glass.
4. Remove the S-Board Block.
(Remove to the Removal of the S-Board)
5. Remove the K-Board.
(Remove to the Removal of the K-Board)
6. Remove the GK-Board.
(Remove to the Removal of the GK-Board)
7. Remove the 5 screws(E) and then remove the Plate(B).
8. Remove the 2 screws(F) and then remove the Control
Panel.
16
TH-37PG9W / TH-42PG9W
9. Remove the 1 screw(G) and then remove the Spring.
10. Remove the 3 hooks and then remove the Door.
11. Remove the 4 hooks and then remove the Power SW.
12. Remove the each screws and then remove the Glass Fixed
Plate (A, B, C, D).
· TH-42PG9W
Removed number of screws: 25
Note: when Front Glass is removed
· Each Front Glass Sponge must be stuck along the
edge of Fixed Angle.
Note
· The sponges are parts which cannot be recycled.
Please use the new article when you exchange the
Front Glass.
13. Remove the each 1 screw and then remove the Plate(L, R).
14. Remove the each 4 screws and then remove the Speaker
(L, R).
· TH-37PG9W
Removed number of screws: 23
15. Remove the Escutcheon.
17
TH-37PG9W / TH-42PG9W
6.20. Removal of the Plasma Panel
· The C1,C2 module is connected with the plasma panel
for the repair.
1. Remove the each 6 screws and then remove the Stand
Blocks.
3. Remove the 4 screws and then remove the Slot Block.
6. Disconnect the couplers(P2, P9, P11, P12, P23, P25).
7. Remove the 6 screws and then remove the P-Board.
8. Disconnect the coupler(D20).
9. Remove the Flexible Cable from the couplers(C11, C21).
10. Remove the 4 screws and then remove the D-Board.
4. Remove the Flexible Cable from the couplers(DA2).
5. Remove the 4 screws and then remove the D-Board Block.
11. Remove the SU-Board and the SD-Board.
(Reference to Removal of the SU-Board and the SD-Board)
12. Remove the 6 screws and then remove the SC-Board.
18
TH-37PG9W / TH-42PG9W
13. Disconnect the couplers(SS23, SS34).
14. Remove the Flexible Cable from the couplers(SS41, SS42,
SS43, SS44).
15. Remove the 6 screws and then remove the SS-Board.
16. Remove the Flexible Cable from the couplers(C12, C22).
17. Remove the 3 screws and then remove the C1-Board.
20. Remove the 6 Spacers and Spacer Rings from the Plasma
Panel.
Caution
· Please confirm the installation place of Spacer and
Spacer Ring when you exchange the Plasma Panel,
and install Spacer and Spacer Ring in an original
installation place after exchanging the Plasma
Panel.
21. Lift up the bottom of the Plasma Panel in the direction of the
arrow1 and pull the Plasma Panel in the direction of the
arrow2 and then remove the Plasma Panel.
18. Remove the 3 screws(H) and then remove the AC Inlet
Block.
19. Remove the 2 screws(J) and then remove the plate(C).
19
TH-37PG9W / TH-42PG9W
7 Location of Lead Wiring
7.1. Location of Lead Wiring (1)
The lead wiring is dressed as shown in figure.
20
7.2. Location of Lead wiring (2)
The lead wiring is dressed as shown in figure.
TH-37PG9W / TH-42PG9W
21
TH-37PG9W / TH-42PG9W
7.3. Location of Lead wiring (3)
The lead wiring is dressed as shown in figure.
22
7.4. Location of Lead Wiring (4)
The lead wiring is dressed as shown in figure.
TH-37PG9W / TH-42PG9W
23
TH-37PG9W / TH-42PG9W
8 Adjustment Procedure
8.1. Driver Set-up
8.1.1. Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-90V, Voltage of Vscn is 35V ±4V.
8.1.2. Adjustments
Adjust driver section voltages referring the panel data on the
panel data label.
Check or adjust the following voltages with the multimeter.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 170±5µ Sec.
Test pointVolumeLevel
T2TPSC1 (SC)VR6602 (SC)170 ± 5µ Sec.
TH-37PG9W / TH-42PG9W
8.3. P.C.B. (Printed Circuit Board) exchange
8.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.NameTest PointVoltageVolumeRemarks
P BoardVsusTPVSUS (SS)Vsus ± 1VR628 (P)*
VdatP12-1, 5 (P)70.2V ± 0.1VR665 (P)
PFCC446 (+) (-) (P)396V ± 0.5VR443 (P)
SC BoardVadTPVAD (SC)-90V ± 1VVR6600 (SC)
SS BoardVeTPVE (SS)Ve ± 2VVR6000 (SS)*
D, J, DA BoardWhite balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DA BoardSet Market Select Number to correct destination by MS mode. (See chap. 9.1.4)
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
25
TH-37PG9W / TH-42PG9W
8.4. Adjustment Volume Location
8.4.1. TH-37PG9W
8.4.2. TH-42PG9W
26
8.5. Test Point Location
8.5.1. TH-37PG9W
TH-37PG9W / TH-42PG9W
8.5.2. TH-42PG9W
27
TH-37PG9W / TH-42PG9W
9 Service mode
9.1. CAT (computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
9.1.1. IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button
on the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
28
TH-37PG9W / TH-42PG9W
9.1.2. CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button
on the remote control more than 5 seconds.
Micom software version (IC9702), this version can be upgrade by
1. replace of new version IC
2. Loading the new version software from loader tool, TZSC07036.
Memory data change
To exit the CD mode, press the R button on the remote control.
9.1.3. SD mode
Select the SD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button
on the remote control.
To exit the SD mode, press the R button on the remote control.
29
TH-37PG9W / TH-42PG9W
9.1.4. MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button
on the remote control more than 5 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of DA-Board.
9North America (Hotel)23-10Europe (Hotel)24-11Others (Hotel)25-12Britain (Hotel)26--
NumberDestination
Default setting
1North America
9.1.5. ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 5 seconds.
To exit the ID mode, press the R button on the remote control.
30
Loading...
+ 148 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.