Switch-M16eG is an all Giga bit Ethernet Switching Hub with management function having 14 ports of
10/100/1000BASE-T and two pairs of 10/100/1000BASE-T port and SFP extension slot, one of which is selectable.
2. Feature
(1) Has wire-speed Layer 2 switching function.
(2) Ports 1 to 14 are 10/100/1000BASE-T ports corresponding to auto-negotiation.
Also their speed and communication mode can be switched by configuration.
Ports 15 and 16 can be used as a 10/100/1000BASE-T port corresponding to auto-negotiation or an SFP extension slot
exclusively.
Also their speed and communication mode can be switched by configuration.
(3) All twisted pair ports support straight/cross cable auto sensing function.
Simply connect devices with straight cables, whether it is a terminal or a network device.
(This function does not work if the port communication configuration is set at Fixed or Link Aggregation.
Ports 1 to 14 are set at MDI-X. (default))
(4) Has a loop detection function, which notifies when a loop occurs with the corresponding port LED and automatically
shuts down the looped port.
401-28160K-ID-SP02
Page 1 of 10
(5) Has a loop detection history function, which notifies when a loop occurs with the corresponding LED and enables a network
administrator to identify the looped port after the loop is removed.
(6) Fan less design solves noise problem or fan failure.
(7) Due to the ECO mode LED function, Port LED lamps (left) can be turned off to reduce power consumption.
(8) The IEEE802.1p compatible QoS function is supported.
(9) Has an internet mansion function, which ensures security between each port.
(10) Due to the loop detection/shutoff function, a port where loop has occurred can be automatically shut off to prevent loop failures.
When a port is shut off and recovered automatically, SNMP trap can be sent to notify the incident to the administrator.
Moreover, the port with a loop can be identified by loop notification on the LEDs on the main unit and referring the history
of loop on the setting screen.
(11) Has a port grouping function, which groups ports that are allowed to communicate with one another to limit communications
between different groups.
(12) Equipped with energy efficient Ethernet (EEE) conforming to IEEE802.3az (LPI).
When there is no data transmission at link up, the energy-saving state automatically starts so that power consumption
can be reduced on each port.
(13) Using Embedded power-saving mode, connection status is automatically detected and power consumption is minimized.
(14) Supports IEEE802.1Q tagging VLAN. Up to 256 groups of VLAN can be registered.
(15) Supports IEEE802.1X user authentication function (EAP-MD5/TLS/PEAP).
(16) Supports ZEQUO assist Plus. Processes from introduction to maintenance can be performed easily.
Date issued
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Date revised
Oct. 1, 2020
Page 2
Model
Name
Model
No.
Switch-M16eG
PN28160K-ID
3. Rated/Environmental Conditions
3-1. Power supply
3-2. Power consumption
3-3. Operating environmentTemperature: 0 - 50℃
3-4. Storage environment
3-5. EMC complianceCISPR 22
3-6. Safety complianceIEC 60950-1
3-7. Environment compliance
401-28160K-ID-SP02
Product Specification
Page 2 of 10
AC100-240V, 50/60Hz, 0.5A (with a built-in power supply)
Normally, Max.13.2W, Min.6.4W
EN 55022 Class A
AS/NZS CISPR22 Class A
VCCI Class A
EN 61000-3-2, EN 61000-3-3
CISPR 24
EN 55024
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
EN 60950-1
RoHS compliant
4.Form
4-1. Form and materials/colors
4-2. Mass(Weight)2,200g
Dimensions:44mm(Height)×330mm(Width)×230mm(Depth)
(Excluding protruding sections)
Case material:SECC
Color: Main unit: Green 03, Front face: Black 03,
Face plate label: Black 04
Date issued
Date revised
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Page 3
Model
Name
Model
No.
Switch-M16eG
PN28160K-ID
5. Hardware Specifications
401-28160K-ID-SP02
Product Specification
Page 3 of 10
5-1. Interface
5-2. Switching mode
5-3. Terminal emulator
connection
Twisted pair port 1-16:RJ45 connector (*1)
Transmitting and receiving network system
:IEEE802.310BASE-T
IEEE802.3u100BASE-TX
IEEE802.3ab1000BASE-T
Transmission speed:10/100Mbps, full/half duplex
:1000Mbps, full duplex
Compatible cable:Twisted pair cable
(At least equivalent to EIA/TIA568 category 5e)
Maximum transmission distance:100m
Auto-Negotiation:Communication speed and full/half duplex are
automatically recognized.
The setting can be fixed to 10Mbps, 100Mbps,
and full duplex or half duplex.
*1 Embedded power saving mode detects the connection status automatically
and saves power consumption to minimum.
SFP extension slot 15,16
SFF-8472(DMI:Diagnostic Monitoring Interface)
*Select either of RJ45 or SFP for use
Optional Accessories:1000BASE-SX SFP Module (PN54021K-ID)
1000BASE-LX SFP Module (PN54023K-ID)
Switching method:Store and Forward
Switching capacity:32Gbps
Packet transfer capability:Non-blocking
Max 1,488,000pps/port(1000Mbps)
Max 148,800pps/port(100Mbps)
Max 14,880pps/port(10Mbps)
MAC Address table:Max 8K entry/unit
Buffer memory:512K Byte/unit
Flow control:half-duplex Back pressure
full-duplex IEEE802.3x
Aging timeout:10 to 1,000,000 sec. (Default: 300 sec.)
Jumbo frame supported:9KB
Transmittable frames:EAP,BPDU
Orange Light : During half-duplex operation, packet collision is
occurring in either port.
(3)STATUS/ECO (Status/ECO made)LED
Green Light : Operating in Status mode.
Green Blink : Operating in ECO mode.
All port LEDs(left) are turned off.
Orange Light : Starting
Orange Blink : Malfunction(Contact the seller)
Off : Power is OFF.
(4)GIGA(GIGA mode)LED
Green Light : Operating in GIGA mode.
(5)100M(Speed mode)
Green Light : Operating in Speed mode.
(6)FULL (DUPLEX mode)LED
Green Light : Operating in DUPLEX mode.
(7)LOOP HISTORY(Loop History mode)LED
Green Light : Operating in Loop History mode.
Green Blink: Loop is occurring,
or occurred within the last 3days.
401-28160K-ID-SP02
Page 4 of 10
Display of each port
is refer to table 1
of No.4 .
You can display the following items using the LED display change button.
Display for the connection with a connected terminal (Status mode), Display for
the 1000 Mbps transmission rate (GIGA mode) , Display for the 100Mbps or 10 Mbps
transmission rate (Speed mode), Display for the full-duplex or half-duplex
transmission system (DUPLEX mode), Display for ports with a loop history (Loop
history mode), All port LED lamps can be turned OFF (ECO mode).
The mode at the start is called “Base mode”.
There are two types of Base modes : Status mode (factory default setting) and
ECO mode. You can change the Base mode by holding down the LED display change
button (for at least 3 sec).
When the Base mode is changed normally, all STATUS/ECO , GIGA , 100M , and
FULL LED lamps light up at the same time. When you release the button, the Base
mode is changed to the selected mode.
If the mode is changed to the GIGA mode, Speed mode , DUPLEX mode, or
Loop History mode and the LED display switch button is not used for one minute or
longer, the mode automatically returns to a Base mode (Status mode or ECO mode).
The Base mode is maintained even after the power is turned OFF.
Date issued
Date revised
LED display change button
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Page 5
Model
Name
Switch-M16eG
Model
No.
PN28160K-ID
5. Hardware Specifications
5-4. LED displaySwitch two types of Base mode s and their LEDs in the following way:
Product Specification
When Base mode is Status mode (factory default setting)
Automatically returns to Base mode after 1 minute.
401-28160K-ID-SP02
Page 5 of 10
Status mode
(Base mode)
When Base mode is ECO mode
Boot
ECO mode
(Base mode)
LED lamps for each mode and LED lamps for ports 1 to 16 correspond as the following.
(Table 1)
Port
LED
Left
Right
Display modeBehaviorDescription
STATUS/ECO
GIGA
100M
Full
LOOP
HISTORY
-
GIGA modeSpeed mode
Status
mode
Port LED(Left)
GIGA
mode
Table 1
Green Light
Green Blink
Off
Green Light
Off
Green Light
Off
Green Light
Off
Green Light
Off
Orange Light
Off
Switch Base mode(keep pressing “LED DISPLAY
Press “LED DISPLAY CHANGE BUTTON” manually.
Automatic
Automatically returns to Base mode after 1 minute.
Speed
mode
Link is established
Transmitting and receiving data.
No device connected.
Link is established at 1000Mbps.
Link is established at 100Mbps or
10Mbps , or no device is connected.
Link is established at 100Mbps.
Link is established at 1000Mbps or
10Mbps , or no device is connected.
Link is established at full-duplex.
Link is established at half-duplex or
or no device is connected.
Loop has been detected within the
last 3 days.
No loop detection history.
Shutting down by loop detection.
Not shutting down by loop detection.
DUPLEX
mode
CHANGE BUTTON” over 3 seconds)
DUPLEX
mode
Loop History
mode
Loop History
mode
Date issued
Date revised
Port LED(Right)
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Page 6
Model
Name
Model
No.
Switch-M16eG
PN28160K-ID
6. Software Specifications
401-28160K-ID-SP02
Product Specification
Page 6 of 10
6-1. Configuration
6-2. Switching Hub Control
6-3. Rebooting
6-4. Supported Agent
6-5. Supported MIB
Control parameters can be set by the following procedures:
(1) Configuration from an asynchronous terminal connected to the console port.
(2) Configuration from a remote terminal connected via TELNET and SSH
Switching Hub can be controlled by the following procedures:
(1) Control from an asynchronous terminal connected to the console port.
(2) Control from a remote terminal using SSH/TELNET and TCP/IP network
connection
(3) Control using SNMP Manager
The switching Hub operation status can be checked using the following functions.
(1) Function to display the CPU usage and memory usage
(2) SFP module status checking function (DDM: Digital Diagnostic Monitoring)
The system can be reset from the software in the following three modes:
(1) Warm start
(2) Reset to factory default
(3) Reset items other than the IP address to factory default
The reboot timer function can also be used in each mode.
Turns on the port LED with a orange light when a loop occurs in the corresponding port.
At this time, the relevant port automatically shuts down to prevent loop from occurring.
SNMP trap can be sent to notify the incident to the administrator.
During loop is occurring, or if loop has occurred within the latest 3 days,
LOOP HISTORY LED blinks to notify this.
• Loop detection setting
Enabled (factory default setting)
Enabled/disabled can be switched by configuring a setting using
the console, or by pressing "LED DISPLAY CHANGE BUTTON"
for 10 seconds or more.
The setting is kept even when the power is turned OFF.
• Loop detection port
Enabled: Ports 1 to 14 (factory default setting)
Disabled: Ports 15 and 16 (factory default setting)
• Loop shutoff time
60 to 86,400 sec. (Factory default setting: 60 sec.)
The set time Port LED lights up orange and the port shuts off.
• Loop history retention time
3 days
The LOOP HISTORY LED lamp flashes for three days.
The Port LED lamp also remains lit for three days after
the loop is eliminated.
ZEQUO assist Plus
Syslog Client (Transfers system logs to the Syslog server.)
TFTP Client (Upgrades the software and saves/loads configuration information.)
Login RADIUS (login authentication function by the RADIUS server)
7. Layer 2 Switching Functions
7-1. Port groupingMembers of the port group can communicate only among member ports in
the same group.
(Number of group registrations: 256)
7-2. VLAN
7-3. TrunkingIEEE802.ad Link Aggregation function (STATIC)
7-4. Port MonitoringTraffic of the target port can be copied to the specified port and transmitted.
(1) IP address (Source or Destination)
(2) IPv6 address (Source or Destination)
(3) MAC address (Source or Destination)
(4) TCP/UDP port number (Source or Destination)
(5) VLAN ID
(6) IEEE 802.1p Priority
(7) DSCP
(8) Protocol
(9) ICMP type
(10)TCP SYN Flag
Manual mode setting
Date issued
Date revised
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Page 8
Model
Name
Model
No.
Switch-M16eG
PN28160K-ID
8. Connector Pin Arrangement
8-1. Port 1 - 16
Status
MDI-X
8-2. Console port
MDI
Pin No.
Signal
Signal
12364 587
BI_DB+
BI_DA+
BI_DB-
BI_DA-
BI_DA+
BI_DB+
Product Specification
BI_DA- BI_DD+
BI_DB- BI_DC+
BI_DD-
BI_DC-
BI_DC+
BI_DD+
BI_DC-
BI_DD-
401-28160K-ID-SP02
Page 8 of 10
Pin No.
1 2 3 4 5 6 7 8
Pin No.
1
2
3
4
Signal
NC
NC
TXD
GND
Pin No.
5
6
7
8
9. Installation Procedures and Accessories
9-1.Installation ProceduresMounting to rack
9-2.Accessories
(1) Installation Guide:1
(2) CD-ROM(*1):1
(3) Mounting bracket (for 19-inch rack):2
(4) Screw(for 19-inch rack):4
(5) Screw (for fixing the main unit and the 19 inch rack mount bracket):8
(6) Rubber foot:4
(7) Power cord (CEE7/7)(*2):1
*1 We discontinued the CD-ROM from October 2020's production lots.
*2 The attached power cord is dedicated for AC 100 - 240 V use.
10. Optional Accessories
10-1. 1000BASE-SX
SFP Module
(Model No.:PN54021K-ID)
10-2. 1000BASE-LX
SFP Module
(Model No.:PN54023K-ID)
Fiber optic port connector type :LC connector (Duplex)
Standards:IEEE802.3z1000BASE-SX
Transmission speed:1000Mbps, full duplex
Compatible cable:Fiber cable
Maximum transmission distance:550 m at 50/125 μm
Fiber optic port connector type :LC connector (Duplex)
Standards:IEEE802.3z1000BASE-LX
Transmission speed:1000Mbps, full duplex
Compatible cable:Fiber cable
Maximum transmission distance:10 km when Single Mode Fiber is used
Signal
GND
RXD
NC
NC
Pin No.
50/125μm Multi Mode Fiber
62.5/125μm Multi Mode Fiber
220 m at 62.5/125 μm
10/125μm Single Mode Fiber
50/125μm Multi Mode Fiber
62.5/125μm Multi Mode Fiber
550 m when Multi Mode Fiber is used
1 2 3 4 5 6 7 8
Date issued
Date revised
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Page 9
Model
Name
Model
No.
Switch-M16eG
Product Specification
PN28160K-ID
11. Prohibitions when Using the Product to Guarantee Safety
The manufacturer assumes no responsibility for any problems occurring when the following conditions are not satisfied.
Observe the following items when using the product.
(1) Do not use power supply other than AC 100 - 240 V.
Deviation could lead to fire, electric shock, and/or equipment failure.
401-28160K-ID-SP02
Page 9 of 10
(2) Do not handle the power cord with wet hand
Deviation could lead to fire, electric shock.
(3) Do not handle this Switching Hub and connection cables during a thunderstorm.
Deviation could lead to electric shock.
(4) Do not disassemble and/or modify this Switching Hub.
Deviation could lead to fire, electric shock, and/or equipment failure.
(5) Do not damage the power cord. Do not bend too tightly, stretch, twist, bundle with other cord, pinch, put under a heavy
object and/or heat it.
Damaged power cord could lead to fire, short, and/or electric shock.
(6) Do not unplug nor plug in the power plug with wet hands.
Deviation could lead to electrical shock, and/or equipment failure.
(7) Do not insert nor drop any foreign objects such as metal or readily combustible things into the inside through the openings.
Deviation could lead to fire, electrical shock, and/or equipment failure.
(8) Do not store or use the Switching Hub in places where it
humidity, in places with conductive dust, or in places where there are corrosive and combustible gases.
Deviation could lead to fire, electrical shock, and/or equipment failure.
(9) Do not store or use the Switching Hub in places where it will be exposed to direct sunlight or high temperatures.
The temperature inside will rise, which may cause fire.
(10) Do not store or use the Switching Hub in places where there are lots of vibrations and impacts, or in unstable areas.
It might fall, which may cause injuries and/or equipment failure.
.
might get splashed with liquids such as water, in places with a lot of
(11) Do not put the Switching Hub into fire.
Deviation could lead to explosion and/or fire.
(12) Do not insert nor drop any foreign objects such as metal or readily combustible things into the inside through the openings,
twisted pair ports, console ports, SFP extension slots, or SD card slots.
Deviation could lead to fire, electrical shock, and/or equipment failure.
12. Basic Instructions for the Use of This Product
Handle the Switching Hub carefully so that fingers or hands may not be damaged by twisted pair port, SFP extension slot,
(1)
console port, or power cord hook block.
(2) Do not connect any other devices except for 10BASE-T/100BASE-TX/1000BASE-T devices to the twisted pair ports.
Deviation could lead to equipment failure.
(3) Do not mount any other modules except for the separately sold SFP module (PN54021K/PN54023K) to the SFP extension
slots.
(4) Unplug the power plug when there is a malfunction.
Deviation could lead to fire if the power is allowed to be supplied for extended periods of time.
(5) Be sure to connect the ground cable.
-Otherwise this might cause electrical shocks, misoperations and malfunctions.
-Connect the Switching Hub via the supplied power cord to the outlet which is connected to the ground.
-If the outlet is not connected to a ground, connect the ground cable to the ground terminal screw.
Date issued
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Date revised
Oct. 1, 2020
Page 10
Model
Name
Model
No.
Switch-M16eG
Product Specification
PN28160K-ID
12. Basic Instructions for the Use of This Product
(6) Use the bundled power cord (AC 100 – 240 V specifications).
Deviation could lead to electric shock, malfunction, and/or equipment failure.
(7) Unplug the power cord in case of equipment failure.
Deviation, such as keeping connected for a long time, could lead to fire.
(8) Connect this Switching Hub to ground.
Deviation could lead to electric shock, malfunction, and/or equipment failure.
(9) Connect the power cord firmly to the power port.
Deviation could lead to electric fire, shock, and/or malfunction.
(10) Unplug the power cord if the STATUS LED blinks in orange (system fault).
Deviation, such as keeping connected for a long time, could lead to fire.
(11) This Switching Hub is to be periodically serviced in order to maintain its performance.
Please choose a product administrator, and have them be sure to implement periodic maintenance. When doing maintenance,
check the inspection chart that is posted on our website which has the requisite items listed on it.
(12) When using this Switching Hub to design systems, use it after applying appropriate measures such as setting up
redundant configurations.
Communications failures might be generated due to causes such as malfunctions or misoperations while the Switching Hub is
being used.
401-28160K-ID-SP02
Page 10 of 10
(13) When using this Switching Hub for applications which require extremely high reliability, be careful to expend all possible
means to ensure safety and reliability.
This Switching Hub was not designed nor manufactured with the intention that it be used for applications (in use with railways,
aviation, and medical care, etc. whereas the influence rate due to communications failures is extremely high in regard to
systems that directly affect systems and human lives) which require extremely high reliability.
(14) It is strongly recommended that a lightning arrester (SPD) be installed on the twisted pair port side and the power supply side
of this Switching Hub.
Malfunctions might be caused due to overcurrent and overvoltage due to the effects of lightning strikes.
(15) It is recommended that this Switching Hub be replaced about five years after it has been installed.
This may vary depending upon conditions such as utilisation rates and usage environments, but performance might decrease
due to the age-related degradation, etc. of components.
(16) Be careful in regards to environmental restrictions whereby the Switching Hub can be used.
Please isolate the business power lines and communications lines. Isolate distribution lines and other distribution lines,
and low current power lines, optical fiber cables, metallic water conduits, and gas conduits, etc. Noise may be generated in
the communications lines which might cause communications glitches.
Date issued
Date revised
July 12, 2016
Panasonic Life Solutions Networks Co., Ltd.
Oct. 1, 2020
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.