9.11. Disassembly of Memory P.C.B.-----------------------52
9.12. Disassembly of MPort/Headphone P.C.B. --------- 53
9.13. Disassembly of CD Servo P.C.B.--------------------- 54
9.14. Disassembly of D-Amp P.C.B. ------------------------ 55
9.15. Replacement of Audio Digital Amp IC
(IC5400) ---------------------------------------------------- 57
9.16. Replacement of Audio Digital Amp IC
(IC5000) ---------------------------------------------------- 58
9.17. Disassembly of Main P.C.B. --------------------------- 59
9.18. Disassembly of SMPS P.C.B. ------------------------- 60
9.19. Replacement of Switching Regulator IC
(IC5701) ---------------------------------------------------- 61
9.20. Replacement of Rectifier Diode (D5702)----------- 62
9.21. Replacement of Regulator Diode (D5801)---------64
9.22. Replacement of Regulator Diode (D5802)---------65
9.23. Replacement of Regulator Diode (D5803)---------66
9.24. Disassembly of AC Inlet P.C.B.-----------------------67
9.25. Disassembly of Jupiter P.C.B.------------------------- 68
9.26. Disassembly of Voltage Selector P.C.B. (For
PH only) ----------------------------------------------------69
9.27. Replacement of Traverse Unit Assembly ---------- 70
9.28. Disassembly of CD Lid----------------------------------72
10 Service Position ------------------------------------------------- 73
10.1. Checking and Repairing of Main P.C.B. ------------ 73
10.2. Checking and Repairing of Panel P.C.B., Mic
P.C.B., Jupiter P.C.B. and MPort/Headphone
P.C.B.-------------------------------------------------------- 73
10.3. Checking and Repairing of D-Amp P.C.B. --------- 74
10.4. Checking and Repairing of SMPS P.C.B. and
AC Inlet P.C.B.-------------------------------------------- 75
11 Voltage & Waveform Chart ---------------------------------- 76
11.1. CD Servo P.C.B. ----------------------------------------- 76
11.2. Main P.C.B. (1/3)----------------------------------------- 77
11.3. Main P.C.B. (2/3)----------------------------------------- 78
11.4. Main P.C.B. (3/3)----------------------------------------- 79
17.5. SMPS / AC Inlet / Voltage Selector P.C.B. (For
PH) --------------------------------------------------------- 120
17.6. SMPS/ AC Inlet P.C.B. (For PN) -------------------- 121
18 Terminal Function of ICs ------------------------------------ 122
2
18.1. IC2801 (RFKWMAK580PN): IC
Microprocessor------------------------------------------ 122
18.2. IC6601(C0HBB0000057): IC FL Driver -----------124
19 Exploded View and Replacement Parts List --------- 125
19.1. Exploded View and Mechanical Replacement
Parts List-------------------------------------------------- 125
19.2. Electrical Replacement Part List-------------------- 130
3
1Safety Precautions
1.1.General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, carry out the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1MΩ and 5.2MΩ.
When the exposed metal does not have a return path to the chassis, the reading must be
1.1.2.Leakage Current Hot Check
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5kΩ, 10 watts resistor, in parallel with a 0.15μF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the
limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is
returned to the customer.
Figure 1
1.2.Before Use (For PH only)
Be sure to disconnect the mains cord before adjusting the voltage selector.
Use a minus(-) screwdriver to set the voltage selector (on the rear panel) to the voltage setting for the area in which the unit will be
used. (If the power supply in your area is 110V ~ 127V or 220V ~ 240V, set to the “110V ~ 127V or 220V ~ 240V” position.)
Note that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries,
the correct voltage is already set.)
1.3.Caution For Fuse Replacement
4
1.4.Before Repair and Adjustment
Disconnect AC power to discharge unit AC Capacitors as such (C5700, C5701, C5703, C5704, C5705, C5706, C5707) through a
10 Ω, 10 W resistor to ground.
Caution:
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 110V~127V / 220V~240V, 50/60 Hz in NO SIGNAL mode volume minimal should be ~ 500 mA (For PH
only).
Current consumption at AC 120V, 60 Hz in NO SIGNAL mode volume minimal should be ~ 500 mA (For PN only).
1.5.Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
• No sound is heard when the power is turned on.
• Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.6.Safety Parts Information
Safety Parts List:
There are special components used in this equipment which are important for safety.
These parts are marked by in the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design
without permission of manufacturer.
Table 1
SafetyRef. No.Part No.Part Name & DescriptionRemarks
6REXX0687-1BLUE WIRE (VOLT SELECTOR -SMPS)PH
13REZX0024-1BLACK WIRE (AC INLET-SMPS)PH
13REXX0684-1BLACK WIRE (AC INLET-SMPS)PN
14REXX0685-1RED WIRE (AC INLET-SMPS)PN
14REZX0023-1RED WIRE (AC INLET-SMPS)PH
15REXX0686-1WHITE WIRE (VOLT SELECTOR-SMPS)PH
22RGRX0070AAA2REAR PANELPH
22RGRX0070Z-D1REAR PANELPN
41RKMX0144A-KTOP CABINET
340RAEX0190A-VTRAVERSE ASS’Y(RTL)
A2K2CB2CB00021AC CORDPN
A2K2CQ2CA00007AC CORDPH
A3RQTX0265-1MO/I BOOK (En/Sp)PN
A3RQTX0266-1MO/I BOOK (Sp)PH
PCB1REPX0714JSMPS P.C.B.(RTL) PN
PCB1REPX0714KSMPS P.C.B.(RTL) PH
PCB4REPX0714JAC INLET P.C.B.(RTL) PN
PCB4REPX0714KAC INLET P.C.B.(RTL) PH
PCB9REPX0714KVOLTAGE SELECTOR P.C.B.(RTL) PH
DZ5701ERZV10V511CSZNR
S5701K0ABCA000007SW VOLTAGE SELECTORPH
L5702ELF22V035BLINE FILTER
T2900G4D1A0000117SWITCHING TRANSFORMER
T5701ETS48AB116ACMAIN TRANSFORMERPH
T5701ETS48AB12GACMAIN TRANSFORMERPN
T5751ETS19AB256AGSUB TRANSFORMER
PC5701B3PBA0000402PHOTO COUPLER
PC5702B3PBA0000402PHOTO COUPLER
PC5720B3PBA0000402PHOTO COUPLER
PC5799B3PBA0000402PHOTO COUPLER
F1K5D802APA008FUSEPN
F1K5D802BNA005FUSEPH
5
SafetyRef. No.Part No.Part Name & DescriptionRemarks
FP2901K5G4013A0001FUSE PROTECTOR
TH5701D4CAA5R10001THERMISTORPN
TH5702D4CAA2R20001THERMISTORPH
TH5860D4CC11040013THERMISTOR
P5701K2AA2B000017AC INLETPH
P5701K2AB2B000011AC INLETPN
C5700F1BAF10200201000pF
C5701F0CAF334A0870.33uF
C5703F0C2H10400010.1uF 500VPH
C5703F0CAF224A0850.22uFPN
C5704F1BAF10200201000pF
C5705F1BAF10200201000pF
C5706F1BAF10200201000pFPH
C5707F1BAF10200201000pFPH
6
2Warning
2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive
(ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as “anti-static (ESD protected)” can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution:
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) suf-
ficient to damage an ES device).
7
2.2.Precaution of Laser Diode
Caution:
This product utilizes a laser diode with the unit turned “on”, invisible laser radiation is emitted from the pickup lens.
Wavelength: 780 nm (CD)
Maximum output radiation power from pickup: 100 μW/VDE
Laser radiation from the pickup unit is safety level, but be sure the followings:
1. Do not disassemble the pickup unit, since radiation from exposed laser diode is dangerous.
2. Do not adjust the variable resistor on the pickup unit. It was already adjusted.
3. Do not look at the focus lens using optical instruments.
4. Recommend not to look at pickup lens for a long time.
8
2.3.Service caution based on Legal restrictions
2.3.1.General description about Lead Free Solder (PbF)
The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this
equipment in considering the globally environmental conservation.
The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin
(Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30 degrees C (86°F) more than that
of the normal solder.
Definition of PCB Lead Free Solder being used
The letter of “PbF” is printed either foil side or components side on the PCB using the lead free solder.
(See right figure)
Service caution for repair work using Lead Free Solder (PbF)
• The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
(Definition: The letter of “PbF” is printed on the PCB using the lead free solder.)
• To put lead free solder, it should be well molten and mixed with the original lead free solder.
• Remove the remaining lead free solder on the PCB cleanly for soldering of the new IC.
• Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt the
lead free solder.
• Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30 degrees
C (662±86°F).
Recommended Lead Free Solder (Service Parts Route.)
• The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01K-----------(0.3mm 100g Reel)
RFKZ06D01K-----------(0.6mm 100g Reel)
RFKZ10D01K-----------(1.0mm 100g Reel)
Note
* Ingredient: tin (Sn), 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
9
2.4.Handling Precautions for Traverse Unit
The laser diode in the optical pickup unit may break down due to static electricity of clothes or human body. Special care must be
taken avoid caution to electrostatic breakdown when servicing and handling the laser diode in the traverse unit.
2.4.1.Cautions to Be Taken in Handling the Optical Pickup Unit
The laser diode in the optical pickup unit may be damaged due to electrostatic discharge generating from clothes or human body.
Special care must be taken avoid caution to electrostatic discharge damage when servicing the laser diode.
1. Do not give a considerable shock to the optical pickup unit as it has an extremely high-precise structure.
2. To prevent the laser diode from the electrostatic discharge damage, the flexible cable of the optical pickup unit removed
should be short-circuited with a short pin or a clip.
3. The flexible cable may be cut off if an excessive force is applied to it. Use caution when handling the flexible cable.
4. The antistatic FPC is connected to the new optical pickup unit. After replacing the optical pickup unit and connecting the flexible cable, cut off the antistatic FPC.
2.4.2.Grounding for electrostatic breakdown prevention
Some devices such as the DVD player use the optical pickup (laser diode) and the optical pickup will be damaged by static electricity in the working environment. Proceed servicing works under the working environment where grounding works is completed.
2.4.2.1.Worktable grounding
1. Put a conductive material (sheet) or iron sheet on the area where the optical pickup is placed, and ground the sheet.
10
2.4.2.2.Human body grounding
1. Use the anti-static wrist strap to discharge the static electricity form your body.
11
3Service Navigation
3.1.Service Information
This service manual contains technical information which will allow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, this information will be followed by supplement service manual to be filed with original service
manual.
• CD Mechanism unit (CR14C):
1) This model uses CD Mechanism Unit (CR14C).
2) This service manual does not contain the following information on CD Mechanism Unit (CR14C)
- Schematic Diagram, Block Diagram and P.C.B. layout of CD Mechanism Unit (CR14C) P.C.B.
- Parts List for individual parts of CD Mechanism Unit (CR14C).
- Exploded View and Part List for individual parts of CD Mechanism Unit (CR14C).
Please refer to original service manual (Order No. MD0805031CE)
• Micro-processor, EEPROM & FLASH ROM IC:
1) The following components are supplied as an assembled part.
- Micro-processor IC, IC2801 (RFKWMAK580PN)
- EEPROM IC, IC2200 (RFKWEAK580PN)
- FLASH ROM IC, IC701 (RFKWFAK580PN)
Before replacement of micro-processor IC, please check the version no. It may need matching with ROM correction.
• Speaker system:
1) The information, please refer to original service manual, SB-AK780PN/PNA-K & SB-WAK780PN-K (PSG0905028CE)
12
4Specifications
Q AMPLIFIER SECTION
RMS output power
Front Ch (both channels driven)250 W per channel (6 Ω), 1 kHz,
Total RMS stereo mode power500 W
PMPO Output Power
For PN only5500 W
Number of channels2 (FL, FR)
FL = Front left channel
FR = Front right channel
SW = Subwoofer channel
Q USB SECTION
USB port
USB standardUSB 2.0 full speed
Media file format supportMP3 (*.mp3)
USB device file systemFAT 12, FAT 16, FAT 32
USB port power500 mA (Max)
Bit rate16 kbps to 320 kbps (P.B)
USB recording
Recording file formatMP3 (*.mp3)
Bit rate128 kbps / 192 kbps / 320 kbps
USB recording speed1x, max 4x (CD only)
Q General
Power supply
For PH onlyAC 110 to 127/220 to 240 V,
50/60 Hz
For PN onlyAC 120 V, 60 Hz
Power consumption112 W
Dimensions (W x H x D)250 mm x 331 mm x 326 mm
Mass4.6 kg
Operating temperature range0°C to +40°C
Operating humidity range35% to 80% RH (no condensation)
Power consumption in standby
mode
For PH only0.5 W (Approximate)
For PN only0.3 W (Approximate)
Notes :
1. Specifications are subject to change without notice.
Mass and dimensions are approximate.
2. Total harmonic distortion is measured by the digital spectrum
analyzer.
Q System: SC-AK580PN-KMain Unit: SA-AK580PN-K
Front Speaker: SB-AK780PN-K
Q System: SC-AK580PH-KMain Unit: SA-AK580PH-K
Front Speaker: SB-AK780PN-K
13
5Location of Controls and Components
5.1.Main Unit Key Button Operation
14
5.2.Remote Control Key Button Operation
TUNE
MODE
This auto off function allows you to turn off
the unit in di sc or USB mode on ly after lef t
unused for 10 minutes.
• Press the button to a ctivate the fu nction.
• Press the button a gain to cancel.
• The setting is mai ntained even if t he unit
is turned off.
Standby/on switch (
/l, POWER)
Press to switch the unit from on
to standby mode or vice versa.
In standby mode, the unit is still
consuming a small amount of power.
Track skip or search, check program
content, preset channel selection,
tuning function, time adjustment,
timer operation, manual EQ setting
USB recording or pause
USB play or pause
Music port selection
AUX selection
Manual EQ selection
Disc play or pause
Tuner (FM/AM) selection
To d im t he d is pla y pa ne l.
• Press the button to a ctivate the fu nction.
• Press the button a gain to cancel.
D.BASS selection
Disc selection
Numeric selection
Delete function
Program function
Play mode function,
Repeat function
RE-MASTER selection
Display function
CD to USB high-speed
recording function
Clock or timer setting
Play timer or record timer
setting
Sleep timer setting
To mute the sound.
• Press the button to a ctivate the fu nction.
• Press the button a gain or adjust th e
volume to ca ncel.
Auto off function
Volume control
Muting function
Stop playback or program clear
Preset EQ selection
Dimmer function
Edit mode function
Recording mode selection
Album selection, Confirm selection
Tuning mode selection
15
5.3.Disc Information
16
6Self-Diagnosis and Special Mode Setting
This unit is equipped with features od self-diagnosis & special mode setting for checking the function & reliability.
Special Note: Checking of the reliability (ageing) & changer operation must be carry out to ensure good working condition in unit.
6.1.Doctor Mode Summary Table
Main unit buttonsRemote control unit buttonsApplicationNote
[]
Doctor Mode[DISPLAY]Cold Start
[PLAYMODE/-REPEAT]Volume 30 Setting Check
[4], [7]Doctor Mode(Refer to the section “6.2.1 Doctor Mode
[2]Micro-P Version Display
[7]Volume 50 Setting Check(Refer to the section “6.2.2 Doctor Mode
[8]Volume 35 Setting Check
[9]Volume 0 Setting Check
[1]FL Display Check
[DEL]CD Open Test
[], [1], [1]
[], [1], [2]
[DISC]CR14 Changer Mechanism Check(Refer to the section “6.2.3 Doctor Mode
[], [9], [4]
[4]CD to USB Recording & Playing Inspection(Refer to the section “6.2.4 Doctor Mode
[FM/AM]Tuner Inspection
[OK]Exit Inspection Mode
CR14 Reliability Test 1 (no retry)
CR14 Reliability Test 2 (with retry)
CR14 Error Late Display
Table 1” for more information.)
Table 2” for more information.)
Table 3” for more information.)
Table 4” for more information.)
17
6.2.Doctor Mode Table
Below is the various special modes for checking:-
6.2.1.Doctor Mode Table 1
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
Doctor ModeTo enter into Doctor
Mode.
Cold StartTo activate cold start upon
next power up when
reset is execute the next
time.
In CD Mode:
1. Press [] button on main unit follow by [4] and [7] on remote control.
To exit Doctor Mode, press [OK] button on
remote control.
In Doctor Mode:
1. Press [DISPLAY] button on remote control.
Micro-P Version
Display
To check the firmware
version for Jupiter &
Microprocessor IC.
Display 1
Display 2
In Doctor Mode:
1. Press [2] button on remote control.
18
6.2.2.Doctor Mode Table 2
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
Volume Setting
Check
To check for the volume
setting of the main unit.
The volume will be automatically set to its respective level (in dB). During
this mode, treble/bass/EQ
will be set to ‘0’dB & OFF.
Display 1In Doctor Mode:
1. Press [7] button on remote control.
To exit Doctor Mode, press [OK] button on main
unit or remote control.
Display 1In Doctor Mode:
2. Press [8] button on remote control.
To exit Doctor Mode, press [OK] button on main
unit or remote control.
FL Display Check To check the FL
CD OPEN Test To check the CD OPEN
CR14 Reliability
Test1 (no retry)
CR14 Reliability
Test2 (with retry)
segments display (All
segments will light up)
operation.
Note:
1. If the mechanism
error occurs, it
should stop the
test.
(no retry, no recovery process).
2. The test mode is
cleared by power
OFF.
3. Reading and playback should not be
done.
Note:
1. Even if the mechanism error occurs, it
should retry as normal operation.
2. The test mode is
cleared by power
OFF.
3. Reading and playback should not be
done.
Display 1In Doctor Mode:
3. Press [9] button on remote control.
To exit Doctor Mode, press [OK] button on main
unit or remote control.
Display 1In Doctor Mode:
4. Press [PLAY MODE/-REPEAT] button on
remote control.
To exit Doctor Mode, press [OK] button on main
unit or remote control.
In Doctor Mode:
1. Press [1] button on remote control.
In Doctor Mode:
1. Press [DEL] button on remote control.
2. Press [OPEN/CLOSE] button on main unit
to close the disc tray.
In Doctor Mode:
1. Press [], [1], [1] button on remote control.
In Doctor Mode:
1. Press [], [1], [2] button on remote control.
19
6.2.3.Doctor Mode Table 3
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
CR14 Inspection Below is the process:
1. Load TRAY 1 (Move to
PLAY position)
2. After that, TRAY 2 is
open (TRAY 1 still in
LOAD condition) and
close.
3. Next TRAY 3 is open
(TRAY 1 still in LOAD
condition) and close.
4. Then TRAY 4 is open
(TRAY 1 still in LOAD
condition) and close.
5. Finally TRAY 5 is open
(TRAY 1 still in LOAD
condition) and close.
6. Tray 1 is unloaded.
(Move to the STOCK
position)
7. Tray 1 is loaded. (Move
to the PLAY position)
When step 1 to 7 operates normally without any error, FL will
display [CHGR_OK_]
CR14 Error Code
Display
To display errors codes for
CR14 changer mechanism.
Refer to section 6.4.1 (CD
Mechanism (CR14) Error code
table).
In Doctor Mode:
1. Press [DISC] button on remote control.
In Doctor Mode:
1. Press [], [9], [4] button on
remote control.
20
6.2.4.Doctor Mode Table 4
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
CD to USB Recording
& Playing Inspection
-Automatically change to CD
-Set it to VOL 0
-Preset EQ Set to FLAT
USB Formatted
When high-speed recording
When analog recording
In Doctor Mode:
1. Press [4] button on remote control.
- Switches to the USB selector
after an analog recording ends
(TRACK 1 of ALBUM1)
During playback this track
- Sets to VOL 50 (0dB) and
start playback
- It is enabled to accept the
SKIP key and the ALBUM key
Next, play the track analog
recorded. (TRACK1 of
ALBUM2)
During playback this track
- It is enabled to accept the
SKIP key and the ALBUM key
21
6.3.Service Mode Summary Table
Main unit buttonsRemote control unit buttonsApplicationNote
[]
Service Mode[1]Error Code History
[]
[2]Micro-P Version Display
[5]USB Error Code History
[6]CD Self Adjustment Result(Refer to the section “6.4.2 Service Mode
[3]Cold Start
Service Mode(Refer to the section “6.4.1 Service Mode
Table 1” for more information.)
Table 2” for more information.)
22
6.4.Service Mode Table
6.4.1.Service Mode Table 1
Below is the various special modes for checking:-
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
Service ModeTo enter into Service
Mode.
Error Code History Checking the records for
Error Code.
In CD Mode:
Press and hold [] button on main unit
for 2 seconds follow by [] on remote control
for 2 seconds.
To exit, press [ON/OFF ] button on main unit
or remote control.
In Service Mode:
1. Press [1] button on remote control.
To clear history, press & hold [0] for 5 seconds or
more.
Micro-P Version
Display
To Check for following:
1) System Version.
2) Jupiter Micro-processor version.
3) Micro-processor Version
In Service Mode:
1. Press [2] button on remote control.
(Display 1)
(Display 2)
USB Error Code
History
To check for USB error
codes.
In Service Mode:
1. Press [5] button on remote control.
To clear history, press & hold [0] for 5 seconds or
more.
23
6.4.2.Service Mode Table 2
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
CD Self Adjustment Result
To check for CD operation
(self-adjusment).
In Service Mode:
1. Press [6] button on remote control.
Cold StartTo reset to default setting.In Service Mode:
1. Press [3] button on remote control.
24
6.5.Reliability Test Mode (CD Mechanism Unit CR14C)
Below is the progress flow chart of ageing for the Mechanism unit (CR14C).
Self-Diagnosis Function (refer Section “6.4.1” Service Mode Table 1”) provides information on any problems occurring for the unit
and its respective components by displaying the error codes. These error code such as U**, H** and F** are stored in memory and
held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
6.6.1.CD Mechanism Unit (CR14C) Error Code Table
26
6.6.2.Error Code Table (For Power Supply)
27
7Troubleshooting Guide
7.1.Jupiter USB
28
7.2.Troubleshooting Guide
29
30
Loading...
+ 110 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.