Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
products, go to www.ahridirectory.org
Quality
Management
System
Certificate
Certified to ISO 9001: 2008
Cert. No.: MY-AR 1010
Environmental
Management
System
Certificate
Certified to ISO 14001: 2004
Cert. No.: MY-ER 0112
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-AR 1010
Certified to ISO 14001: 2004
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-ER 0112
MVA Concealed Duct – Vertical Multi Poise series ..35
CONTROL SYSTEM ...................... 36-39
ACCESSORIES ........................... 40
SERVICES ................................41
Efficiency Rating ......................... 42
A Better Life, A Better World
Since the founding of Panasonic Corporation, our management
philosophy has driven us to contribute to people’s lives and the progress
of society.
In 2018, Panasonic will celebrate its 100th anniversary. As we prepare to
greet a new century in business, the world is witnessing a major turning
point in the way we live. It is no longer practical to pursue extravagant
lifestyles that consume large amounts of natural resources and energy.
We must create a new way of living that minimizes the burden we place
on the environment, while raising our standard of living. This is Panasonic’s
mission – the creation of new lifestyle values.
Through our complete HVAC solutions, we are committed to delivering
“A Better Life, A Better World” to every customer.
A partner in the lives of people all over the world.
For the Living Inside & Out ECOi™ – Your Building Life Tool
Contractors. Building Support.
At Panasonic, we realize contractors are looking for turnkey installation
and support. ECOi™ is quite simply the perfect building solution. With its
modular design and ease of installation, it’s a solution that can grow with
any building project. In fact, ECOi may just remind you why you got into
the business in the first place.
Engineers. Designing Confidence.
ECOi™ is absolute confidence. Its flexibility allows multiple applications
and installation configurations. With a maximum pipe length of up to
3,280 feet and up to 64 units connected to one outdoor system you can
engineer a perfect solution for all your needs. ECOi is a superior modular
option that provides for floor-by-floor commissioning.
Architects. Design Freedom.Now There’s An Idea.
Nobody understands design freedom more than architects. That’s why
the ECOi HVAC system provides more freedom to meet any design need.
With space-saving environmentally-friendly designs, you can design your
vision first then marry our system within your plans.
Owners & Tenants.
Immediate response to changing room capacity, heat loads, and varying
sun exposures throughout the day means everybody stays cool and
comfortable. ECOi ensures individual zone temperature control so each
office or room can be adjusted for personalized comfort. ECOi can grow
with you. As remodeling occurs and building extensions are planned,
ECOi’s modularity lets you simply add on to the system. With intelligent
controllers, VRF technology and R410A refrigerant, ECOi guarantees
continued energy savings and environmental friendship for years to come.
ECOi has a number of diverse features to meet all your air conditioning
needs, including flexible combinations. ECOi allows multiple indoor
unit combinations that provide you with the utmost flexibility.
The system also allows multiple unit connectivity providing up to 200%
of the total capacity of the condensing unit. This provides 20-39 (6-12 tons)
connected to one condensing unit.
Inverter Control Compressor: All ECOi systems utilize highly advanced
inverter controlled compressor technology. By varying the rotational speed
of the compressor, the inverter control can precisely match the amount of
refrigerant being delivered to each zone. This intelligent approach helps
realize the highest efficiencies during partial-load conditions. This allows
all occupants to enjoy consistent room temperature regardless of any
increases or decreases in the heat load during the day. ECOi quite simply
knows what you need, and when you need it throughout the day.
Lower running and life cycle costs: ECOi VRF systems are among the most
efficient systems on the market, offering COPs in excess of 4.0 at full
load conditions. Using our intelligent control sequence, all VRF systems
are designed to minimize running costs. This is done by the most efficient
combination of compressor, fan, and refrigeration management criteria.
Improved defrost sequencing reduces running cost and defrost cycle.
Panasonic commercial HVAC history .... 45
2
3
ECOi
NEW
™
VRF Series
VRF Series
TM
ME2
Panasonic’s combined ECOi EX 2-Way conditioning solution offers superior
heating and cooling coupled with cost effective installation. A smart
conditioning solution for large capacity jobs.
• Outstanding energy saving performance: IEER : 19.1 / EER : 12.3 (in the
case of 6 tons)
• Exceptional flexible piping design:
Maximum total piping length - 3,280 Feet
Maximum outdoor to most distant indoor unit - 164 Feet
• Extended operating range (Outdoor Temperature)
- Cooling 14 °F DB to 122 °F DB
- Heating -4 °F WB to 64 °F WB
• Maximum outdoor unit connects as many as 64 indoor units (50%-200%
ratio of indoor to outdoor capacity)
• Expanded system capacity range (up to 30 tons)
LE
Panasonic 2-WAY mini ECOi is a 2-pipe heat pump specifically designed for numerous
commercial and premium residential applications. Mini ECOi is available in 2 sizes
with cooling capacities ranging with up to 9 indoor units connectable.
• Inverter Driven Twin Rotary Compressor
• One outdoor unit connects as many as 9 indoor units (50%-130% ratio of indoor to
outdoor capacity)
• Nominal operating range (outdoor ambient)
- Cooling 14 °F DB to 113°F DB
- Heating -4 °F WB to 59 °F WB
• Flexible piping design:
Maximum total piping length - 656 Feet
Maximum outdoor to most distant indoor unit - 164 Feet
series
2-WAY MINI ECOiTM VRF HEAT PUMP
2-WAY ECOi EXTM VRF HEAT PUMP
Cooling
NEW ME2 series 2way ECOi EX™
Cooling and Heating Type
LE 2-WAY
Heating
MF
Commercial office buildings are subject to fluctuating heat levels generated from office
equipment, lighting and varying occupant levels. Also, hotels, nursing homes and other
commercial living spaces often have times when occupants will want either heating or
cooling at the same time. The heat recovery system offers the perfect solution for stabilizing
air temperature by providing all the features of a heat pump system and the added flexibility
of simultaneous cooling and heating from one refrigerant pipe network.
• Ultra high performance: efficient individual air conditioning is possible in buildings
having diverse room temperatures for simultaneous heating/cooling and individual
operation of each indoor unit.
• Effective heat recovery system enables higher energy savings
• Improves discharge air temperature of indoor units during heating and simultaneous
mode operation
• Flexible system design with Solenoid Valve Kit (can be piped up to 98 ft. from indoor unit)
Simultaneous Heating & Cooling Operation
3-Way ECO-i™ MULTI
enables simultaneous
heating and cooling
operation by each
solenoid valve kit.
Solenoid valve kit
• CZ-P56HR1U (For 7,500 BTU/H to
19,000 BTU/H)
• CZ-P160HR1U (For 19,100 BTU/H to
54,600 BTU/H)
* For conference rooms and other
locations where low noise is required,
pay attention to the installation location
and install in a corridor etc.
3-WAY ECOiTM VRF HEAT RECOVERY SERIES
[Stop]
MU
[Heating]
MK
Liquid pipe
medium temperature,
medium-pressure liquid pipe
[Cooling]
MF
[Heating]
MD
Suction pipe
low temperature,
low-pressure gas pipe
[Cooling]
ME
ECOi
Cooling and Heating
Simultaneous Type
System example
[Heating]
MT
Discharge pipe
high temperature,
high-pressure gas pipe
For the buildings requiring
simultaneous heating and
cooling, Panasonic 3-Way
ECOi™ system provides
the perfect solution.
4
5
10.0
11.0
12.0
13.0
[EER]
North American IEER
15.0
17.0
16.0
18.0
19.0
20.0
[IEER]
(°C DB)
Cooling
Heating
)
NEW ECOi EX™ Series
Product Advantages
Outstanding
Energy-Saving
Performance
IEER19.3 / EER 12.3 (6, 8, 10, 12 tons) top level in the industry
Thanks to the all inverter compressors combinations with improved combined triple-surface heat
exchanger and medium cooling capacity, the new ME2 Series achieved the industry’s top level
energy saving performance.
ME2 Series
TM
ECOi EX
Exceptional
Design Flexibility
Top
Class
12.3
11.5
CURRENT
9.0
6 tons8 tons10 tons 12 tons
11.9
11.1
NEW
11.5
As of June 2014
10.9
10.9
Up to 30 tons large-capacity single system
Combined outdoor units delivering a maximum of up to
30 tons. (Ducted combination)
Long actual piping length max. of 656 ft
The accumulator, compressor and oil separator are
combined in a single unit to enable long 656 ft
piping (equivalent to 689 ft), 164 ft after first
branch. This extends the piping distance between
indoor units and outdoor units.
(Current models: 492/574 ft, 131 ft after branching)
19.3
19.1
16.7
CURRENT
6 tons8 tons 10 tons 12 tons
19.3
16.3
NEW
18.7
16.7
Top
Class
As of June 2014
Extended
Operating Range
*1: 131 ft if the outdoor unit is
below the indoor unit.
Cooling operation range: 14˚F (WB) to 122˚F (DB)
The cooling operation range has been extended up to 122˚F (DB) (Up to 113°F with current models).
Max. total length: 3280 ft
Cooling is also possible when the outdoor
temperature is 14˚F (WB). Suitable for use
in cold regions where year-round cooling
is required, as well as in the hot regions
where cooling is needed the most.
14°F122°F
1040 50 60 70 80 90 100 110 12020 30
Current [ME1]14°F113°F
New [ME2]
Heating operation range: -4˚F to 64˚F
The heating operation range has been extended
to -4˚F to 64˚F by use of a compressor with a
high-pressure vessel. Provides powerful heating
even in the extremely cold regions.
-4°F59°F
-4°F
010-52050603040
Current [ME1
New [ME2
]
]
64°F
(
°F WB
7
NEW ECOi EX™ Series
Core Technologies
Outstanding
Energy-saving
Technology
1
Dual large-capacity inverter compressors
Two independently controlled inverter compressors
achieve high efficiency (For models U-120ME2U9
and above).
ME2 Series
TM
ECOi EX
4
2
Enlarged heat exchanger surface area
with triple surface
6
5
2
Redesigned
for Smooth
and Better
Air Discharge
1
• The new large size heat exchanger features
a 3-sides construction. Compared to the
conventional 2 (upper/lower) compartments
outdoor unit structure, the new model has more
efficient heat exchanging performance.
3
Gas-liquid separation + oil separation for increased efficiency
• Oil separator: Efficiently separates and absorbs refrigeration oil to prevent it flowing into the
heat exchanger.
4
Large air discharge area with new flush surface top panel.
To reduce air resistance, a new large flat fan guard
design (instead of a tubular fan design), flush with
the top panel, is employed.
This design leads to improvements in air resistance,
and contributes to better appearance.
Current model [ME1]
Current model [ME1]New model [ME2]
New model [ME2]
10, 12 tons
3
5
Newly designed curved air discharge bell mouth for better aerodynamics
The new curved shape with integrated top
and bottom assure smooth air discharge flow.
Minimal swirling means an increased flow rate.
Current model [ME1]New model [ME2]
6
High 80Pa external static pressure – large diameter fan (27-1/2")
A large, newly-designed 27-1/2" diameter fan.
High 80Pa external static pressure maintains
performance in winds around large buildings.
Ideal for high-rise buildings.
8
Max. 80Pa external
static pressure
9
NEW ECOi EX™ Series
High-spec Wired
Multiple Control
Setting Functions
for More Energy
Saving
Temperature Auto Return
Even if you change the temperature setting, after a set time
it automatically returns to the original temperature setting.
You can set temperature auto return in 10-minute intervals
within a period of 4 hours.
ME2 Series
TM
ECOi EX
Remote Controller
NEW
1
Other Convenient
Controls
Temperature Setting Range
Both maximum and minimum temperature settings can be
limited. Doing this helps reduce power consumption due to over
cooling or heating. Setting is possible in the Cooling, Heating and
Dry modes.
Auto Shutoff
Air conditioning operation can be programmed to stop its operation
automatically after a set time, so you don’t have to remember to
manually switch the unit off. Even if you manually switch the unit
back on after it has stopped, the program will continue to activate and
continue to switch off the operation after a set time.
Individual Louver Control
(Lock individual flap only for 4-way cassette MU type)
Each of the 4-directional outlets can be selected and locked to
provide efficient air distribution that matches the indoor unit
layout. Indoor units can be set individually.
2
This lets you select 8 Start/Stop times and temperature presets
for each day of the week.
Service Contact Address
Once you have registered service contact details, they are
Weekly Timer
(CZ-RTC3)
1
Large 3.5" Full-dot LCD with
White LED Backlight
Characters and icons are clearly displayed for
improved visibility. The display is also large enough
to provide a wide range of information for easy
confirmation of operation conditions.
10
2
Stylish, Easy-to-use
Touch Key Design
The elegant, flat design features
large touch keys in a simple layout
enabling easy, intuitive operation.
automatically displayed if a problem occurs. This helps you
address the situation quickly.
Menu items
• Basic instructions
• FLAP
• Individual louver control
(Lock individual flap only
for 4-way cassette MU type)
• ON/ OFF timer
• Weekly timer
• Filter information
• Outing function
• Quiet operation mode
• Energy saving
• Initial settings
• Ventilation
Energy Saving
• Temperature auto return
• Temperature setting range
• Auto shutoff
• Schedule peak cut
• Repeat off timer
• ECONAVI on/ off
Maintenance Function
• Outdoor unit error data
• Service Contact address
• RC setting mode
• Test Run
• Sensor Information
• Service check
• Simple/ Detailed Settings
• Auto address
11
NEW ECOi EX™ Series
ME 2 SERIES
™
ECOi EX
2-WAY VRF HEAT PUMP
The New Panasonic ECOi EX VRF system, redesigned with new DC inverter
compressor combination operations. Perfected original active oil control
system brings quality, efficiency and reliability you can count on.
KEY FEATURES: SINGLE OUTDOOR
* Wide range of systems from 6 ton to 30 ton
* Top class IEER: 19.3 (for 8 ton system)
* Longer max piping length (up to 3,280 ft)
* Increased max number of connectable indoor units (up to 64)
* Increased connectable indoor/outdoor capacity ratio up to 200%
* External static pressure increased to 80Pa
* Extended operation range allowing cooling operation to continue
even when outdoor temperature is as high as 122°F DB
* Heating operation possible down to outdoor temperature of -4°F WB
*1 If the longest tubing equivalent length exceeds 295 ft. (90 m), increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes.
*2 It’s necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit.
* NOTE:
*1
If the longest tubing equivalent length exceeds 295 ft. (90 m), increase the sizes of the main tubes by 1 size for both gas tubes and liquid tubes.
It’s necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit.
*2
13
MF
3-WAY ECOiTM VRF HEAT RECOVERY SERIES
U-72MF1U9
U-96MF1U9
MF
DESCRIPTION
3-WAY ECOiTM VRF HEAT RECOVERY SERIES
U-72MF1U9U-96MF1U9
ECOi Heat Recovery series offers the
ability to heat and cool different zones
simultaneously.
Panasonic was the first manufacturer in the
world to develop this energy saving heat
recovery solution. Offering all the features
of our standard heat pump series, the
3-Way solution can offer even higher energy
savings for the building owner.
KEY FEATURES:
*3-Way Heat Recovery System. Simultaneous Heating and Cooling.
* ECO Friendly R410A Refrigerant
* One Outdoor Unit Connects As Many As 16 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* U-72MF1U9 includes one inverter driven Rotary compressor
* U-96MF1U9 includes one inverter driven Rotary compressor
and one AC Constant Speed Scroll Compressor
* Nominal Operating Range (Outdoor Ambient)
- Cooling 14°F DB to 113°F DB
- Heating -4°F WB to 59°F WB
* Ultra Quiet Operation As Low As 51.5 dB(a)
* Variable Speed DC Fan Motor (ESP adjustable to 0.24" wc)
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor)
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: kW
HEATING CAPACITY: BTU/H
POWER INPUT: kW
ELECTRICAL RATINGS
VOLTAGE RATING
COOLING RUNNING AMPERES
HEATING RUNNING AMPERES
MIN. CIRCUIT AMPACITY
MAX. OVERCURRENT PROTECTION (MOCP): (A)
COMPRESSOR
TYPE - QUANTITY
MOTOR OUTPUT
REFRIGERATION OIL TYPE
REFRIGERATION OIL CHARGE AMOUNT
CRANKCASE HEATER
REFRIGERANT AMOUNT AT SHIPMENT
REFRIGERANT CONTROL
DEFROST METHOD
HEAT EXCHANGER
CAPACITY CONTROL
72,000
5.3
81,000
5.79
208 - 230 V
15.1 - 14.2 A
16.5 - 15.5 A
24 A
40 A
Inverter Driven Rotary Type
4.1 kW
FV68S (Ether oil - PVE)
1.4 gal
25 w
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%