Panasonic LIAV16IM Operating Instructions

Operating Instructions
2 ~ 9
FRANÇAIS
10 ~ 17
18 ~ 25
26 ~ 33
TIMER OUTDOOR
ACTUAL
HEATER
HEAT
TIMER
1
234 56
BOOSTER
MONTUEWEDTHUFRISAT SUN
C
TANK
ON
QUIET
SETTING
OFF
HEATER
STATUS
SOLAR REMOTE
C
FORCE
NOT AVAILABLE
PUMPDW
OPERATION
WATER OUTLET
/ ON
OFF
0.2
0.30.1
0.40
MPa
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and precisely following the installation instructions given.
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure. Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé et dans le strict respect des consignes d’installation fournies.
Air-to-Water Heatpump
Model No. Indoor Unit
LIAC12IM6 LIAV12IM LIAC14IM6 LIAV14IM LIAC16IM6 LIAV16IM
Outdoor Unit
2 ~ 9
10 ~ 17
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf. Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
18 ~ 25
26 ~ 33
F567486
TABLE OF CONTENTS
NOTE
OPERATION CONDITION
WARNING
CAUTION
WARNING
TABLE OF CONTENTS
SAFETY PRECAUTIONS
CONTROL PANEL
INDOOR UNIT
TROUBLESHOOTING
2~3
4~7
SAFETY PRECAUTIONS
• This manual describes how to operate the Heatpump system between indoor and outdoor units only.
Other operation such as water tank, radiator, external thermo controller and underfl oor system, please refer to respective manufacturer operation manuals.
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
CAUTION
8
The instructions to be followed are classifi ed by the following symbols:
9
This sign warns of death or serious injury.
This sign warns of injury or damage to property.
This symbol denotes an action that is PROHIBITED.
INFORMATION
34~35
NOTE
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
OPERATION CONDITION
Water outlet
Temperature (°C)
HEATING
Ambient
Temperature (°C)
HEATING
NOTICE :
When the outdoor temperature
Max. 55
Min. 25
Max. 35
Min. -20
Indoor
Outdoor
is out of the above temperature range, the heating capacity will drop signifi cantly and outdoor unit might stop for protection control.
These symbols denote an action that is COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not attempt to repair the unit by yourself. Otherwise, it may cause injury if it is mishandling.
Do not install the indoor unit at outdoor. This is designed for indoor installation only.
2
/
/
CAUTION
not inspect or service the control panel by
yourself. Please consult authorized dealer.
WARNING
WARNING
POWER SUPPLY
Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
Do not share the same power outlet with other equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric shock.
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
This unit is equipped with Residue Current Circuit Breaker (RCCB). It is strongly recommended to check the operation of the RCCB after installation and periodically after servicing or maintenance by authorized dealer to ensure it is in good working order. Otherwise, it may cause electrical shock or re in case of malfunction.
This equipment is strongly recommended to be installed with Residual Current Device (RCD) on-site according to the respective national wiring rules or country-specifi c safety measures in terms of residual current.
It is recommended to wear gloves during servicing or maintenance in order to avoid hazard.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity. This appliance is for multiple uses. All power
supply circuits must be turn off before access to any of the terminals in the indoor unit, to avoid electrical shock, burn or fatal injury.
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder.
Do not install the unit close to any combustible equipment or at bathroom. Otherwise, it may cause electric shock or fi re.
Do not touch the water discharge pipe at the indoor unit during operation.
Do not place anything on top or beneath of the unit.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Ensure drainage pipe is connected properly. Otherwise, leakage may occur.
Check the installation rack periodically to make sure that it is not damaged. After long periods of use, the strength of the installation rack may have deteriorated.
CONTROL PANEL
Do not let the control panel get wet. Otherwise, it may cause electric shock or fi re.
Do not press the buttons on the control panel with hard, pointed objects. Otherwise, it may damage the unit.
Do not wash the control panel with water, benzene, thinner or scouring powder.
not inspect or service the control panel by
Do yourself. Please consult authorized dealer. Otherwise, it may cause injury if mishandling.
ENGLISH
Examples of abnormality/ failure
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock)
• The RCCB switches off by itself.
• Burning smell, abnormal noise or vibration sound is observed when the unit is in use.
• Hot water keeps on coming off the unit.
Contact immediately your local dealer for maintenance/repair.
Indoor Unit
Outdoor Unit
Control Panel
Shower
Panel
Power Supply
Floor Heating
Water Tank Unit
3
CONTROL PANEL
• Some functions described in this manual may not be applicable to your unit.
• Consult your nearest authorized dealer for further information.
• For normal operation, the
ERROR RESET
,
FORCE
and
PUMPDW
buttons are not in use.
12
13 14 15 16
23
1 2
7
OFF/ON Button
1
Operation LED
2
Operation Mode Button
3
Quiet Operation Button
4
Indoor Unit Backup Heater Enabling Button
5
System Setting Mode Buttons
6
Timer Setting Group Buttons
7
Force Heater Mode Button
8
System Pumpdown Mode Button
9
System Status Check Mode Buttons
10
Error Reset Button
11
Heat Mode OFF/ON Indicator
12
Tank Mode OFF/ON Indicator
13
HEAT
TANK
QUIET
HEATER
FORCE
OPERATION
TIMER
OFF/ON
22
TIMER OUTDOOR
TIMER
1
2 3 4 56
MONTUE WEDTHU FRI SAT SUN
ON OFF
REMOTE
WATER OUTLET
/
ON
OFF
SETTING
SET
MODE
SELECT
QUIET
ERROR
CANCEL
RESET
6 11
14 15 16 17 18 19 20 21 22 23 24 25
24
25
17 18
C
C
ACTUAL
HEATER BOOSTER
SETTING STATUS PUMPDW
19 20
21
3
10
5
CHECK
HEATER
STATUS
SEARCH
PUMPDWFORCECLOCK
9
8
4
Quiet Operation OFF/ON Indicator
Backup Heater Enabled/Disabled Indicator
Force Heater Request OFF/ON Indicator
Backup Heater Actual Operation (OFF/ON) Indicator
Booster Heater Actual Operation (OFF/ON) Indicator
System Setting Mode OFF/ON Indicator
System Status Check Mode OFF/ON Indicator
System Pumpdown Mode OFF/ON Indicator
Timer/Clock Setting Display
External Thermo Controller Connected Display
Outdoor Ambient Temperature Display
Water Outlet Temperature Display
CONTROL PANEL PREPARATION
Setting Current Day and Time
CLOCK
1. Press
2. Press
3. Press
4. Repeat steps 2 and 3 to set the current time.
4
.
or to set current day.
SET
to confi rm.
Notes:
• The current day and time need to be set when:
- The power is turned on for the fi rst time.
- After a long time has elapsed since the power was last turned on.
• The current time that has been set will be the standard time for all the Timer operations.