Panasonic LD Relays ALD User Manual

1 FORM A
Contact arrangement Coil voltage (V DC)
1: 1 Form A 4H: 4.5,
05: 5, 06: 6,
Packing style
Nil:
W:
Tube packing Carton packing
Product name
LD
UL/CSA, TÜV, VDE approved type is standard. Note: Tube packing: Tube: 50pcs, Case: 1,000pcs
Carton packing: Carton: 100pcs, Case: 500pcs
Ex. A LD 1 12 W
09: 9 ,
12: 12 18: 18
24: 24
SLIM POWER RELAY
LD (ALD)
VDE
LD RELAYS (ALD)
FEATURES
1. Slim type: Width 7 mm .276 inch.
20.3(L)×7.0(W)×15.0(H) mm
.799(L)×.276(W)×.591(H) inch
20.3
.799
7.0
.276
15.0
.591
2. Perfect for small load switching of home appliances
5
10
switching operations possible with a
3A 250V AC resistive load.
3. Low operating power
RoHS Directive compatibility information
http://www.nais-e.com/
Compact size, nominal operating power as low as 200mW.
SPECIFICATIONS
Contact
Arrangement 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) Contact material AgSnO2 type
Nominal switching capacity
Rating (resistive load)
Max. switching power
Max. switching voltage 277 V AC, 30 V DC Max. switching current 3 A Min. switching capacity
#1
Mechanical (at 180 cpm) 5×10
Expected life (min.operations)
Electrical (at 20 cpm) (at rated load)
3A 125V AC, 3A 30V DC
3A 250V AC 10
Coil
Nominal operating power 200 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ±1.2×50ms according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT
Max. 100 m
3 A 277 V AC,
3 A 30V DC
831 V A (AC),
90W (DC)
100 mA, 5 V DC
6
5
2×10
5
4. High shock resistance
The relay withstands a functional shock resistance of 300m/s
2
[approx. 30 G
more]
5. High insulation resistance
• Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
• Surge withstand voltage between contact and coil: 10,000 V or more.
6. UL/CSA, VDE, TÜV approved.
Characteristics
Max. operating speed 20 cpm (at rated load) Initial insulation resistance*
Initial*2 breakdown voltage
Initial surge voltage between contact and coil*
Between open contacts
Between contact and coil
3
Operate time*4 (at nominal voltage) Max. 10ms (at 20°C 68°F) Release time (with diode)*4
(at nominal voltage)
Temperature rise (at 70°C 158°F)
Shock resistance
Vibration resistance
Conditions for operation, transport and storage* (Not freezing and condensing at low temperature)
Unit weight Approx. 4 g .14 oz
1
Min. 1,000 M(at 500 V DC)
750 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Max. 10ms (at 20°C 68°F)
Max. 45°C with nominal coil
voltage and at 3 A contact
carrying current
(resistance method)
Ambient temp.
5
Min. 300 m/s2{approx. 30 G}
6
Min. 1,000 m/s2{approx. 100 G}
7
at double amplitude of 1.5mm
10 to 55Hz
10 to 55Hz
at double amplitude of 1.5mm
–40°C to +70°C
–40°F to +158°F
Functional* Destructive*
Functional*
Destructive
8
Humidity 5 to 85% R.H.
TYPICAL APPLICATIONS
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
ORDERING INFORMATION
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LD (ALD)
4-1.1 dia
4-.043 dia
(1.15)
(.045)
(1.05)
(.041)
11.5
.453
4.7
.185
7.0
.276
COIL
COM NO
TYPES AND COIL DATA (at 20°C 68°F)
Nominal
operating
current,
mA (±10%)
Nominal
operating power,
mW
allowable voltage,
(at 20°C 68°F)
Part No.
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
(Initial)
Drop-out voltage,
V DC (min.)
(Initial)
Coil resistance,
(±10%)
ALD14H 4.5 3.38 0.22 101 44.6 200 5.85 ALD105 5 3.75 0.25 125 40.0 200 6.5 ALD106 6 4.5 0.3 180 33.3 200 7.8 ALD109 9 6.75 0.45 405 22.2 200 11.7 ALD112 12 9 0.6 720 16.7 200 15.6 ALD118 18 13.5 0.9 1,620 11.1 200 23.4 ALD124 24 18 1.2 2,880 8.3 200 31.2
DIMENSIONS
Maximum
V DC
PC board pattern (Bottom view)
Schematic (Bottom view)
0.4 dia
016 dia
1.05
.041
Max. 20.5
.807
0.2
.008
11.5
.453
.008
7.0
.276
0.2
Max. 15.3
0.4
.016
3.4
.134
.602
0.8
.031
4.7
.185
Max. 7.2
.284
1.15
.045
Dimension: General tolerance Max. 1mm .039 inch: ±0.1 ±.004 1 to 3mm .039 to .118 inch: ±0.2 ±.008 Min. 3mm .118 inch: ±0.3 ±.012
REFERENCE DATA
1. Max. switching power 2. Life curve 3. Coil temperature rise
3.0
2.0
1.0
0.5
Contact current, A
0.4
0.3
0.2
20 30 50 100 200 3000
AC resistive load
DC resistive load
Contact voltage, V
100
50
30
4
10
Life, ×10
0
123
125V AC resistive load
Contact current, A
Sample: ALD112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 3 A
70
60
50
40
30
Temperature rise, °C
20
10
0
20°C
1000 125 175150
Coil applied voltage, %V
Tolerance: ±0.1 ±.004
0A 3A
70°C
4-(1). Operate time
Sample: ALD112, 6 pcs.
10
8
6
Operate time, ms
4
2
0
Min.
80 100 140120
Coil applied voltage, %V
Max.
4-(2). Release time (without diode)
Sample: ALD112, 6 pcs.
10
8
6
Release time, ms
4
2
0
80 100 140120
Coil applied voltage, %V
Max.
Min.
4-(3). Release time (with diode)
Sample: ALD112, 6 pcs.
10
8
6
Release time, ms
4
2
0
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max.
Min.
80 100 140120
Coil applied voltage, %V
Loading...
+ 1 hidden pages