Panasonic KX-TGD210N, KX-TGD212N, KX-TGD213N, KX-TGD220N, KX-TGD222N Service Manual

...
© Panasonic System Networks Co., Ltd. 2014 Unauthorized copying and distribution is a violation of law.
ORDER NO. KM41401787CE
F13
Telephone Equipment
Model No. KX-TGD210N
Digital Cordless Phone Digital Cordless Answering System
N: Champagne Gold Version (for USA)
KX-TGDA20
(Handset)
(Base Unit)
KX-TGD220
(Base Unit)
KX-TGD210
(Charger Unit)
Configuration for each model
Model No
Base Unit Handset
Charger Unit Expandable
KX-TGD210
Up to 6 KX-TGD212 Up to 6 KX-TGD213 Up to 6 KX-TGD220 Up to 6 KX-TGD222 Up to 6 KX-TGD223 Up to 6 KX-TGD224 Up to 6 KX-TGD225 Up to 6 KX-TG443SK Up to 6 KX-TG444SK Up to 6
1(TGDA20) 1(TGD210) 2(TGDA20) 1(TGD210) 3(TGDA20) 1(TGD210) 1(TGDA20) 1(TGD220) 2(TGDA20) 1(TGD220) 3(TGDA20) 1(TGD220) 4(TGDA20) 1(TGD220) 5(TGDA20) 1(TGD220) 3(TGDA20) 1(TGD220) 4(TGDA20) 1(TGD220)
1 2
1 2 3 4 2
3
KX-TGD210N/KX-TGD212N/KX-TGD213N/KX-TGD220N/KX-TGD222N/KX-TGD223N/KX-TGD224N/KX-TGD225N/ KX-TG443SKN/KX-TG444SKN/KX-TGDA20N
2
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer.
IMPORTANT INFORMATION ABOUT LEAD FREE, (PbF), SOLDERING
If lead free solder was used in the manufacture of this product, the printed circuit boards will be marked PbF. Standard leaded, (Pb), solder can be used as usual on boards without the PbF mark. When this mark does appear, please read and follow the special instructions described in this manual on the use of PbF and how it might be permissible to use Pb solder during service and repair work.
L When you note the serial number, write down all 11 digits. The serial number may be found on the bottom of the unit. L The illustrations in this Service Manual may vary slightly from the actual product.
KX-TGD210N/KX-TGD212N/KX-TGD213N/KX-TGD220N/KX-TGD222N/KX-TGD223N/KX-TGD224N/KX-TGD225N/
KX-TG443SKN/KX-TG444SKN/KX-TGDA20N
3
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 4
1.1. For Service Technicians --------------------------------- 4
2 Warning-------------------------------------------------------------- 4
2.1. Battery Caution--------------------------------------------- 4
2.2. About Lead Free Solder (PbF: Pb free)-------------- 4
2.2.1. Suggested PbF Solder ------------------------------ 5
2.3. Discarding of P. C. Board -------------------------------- 5
3 Specifications ----------------------------------------------------- 6 4 Location of Controls and Components------------------- 7 5 Installation Instructions---------------------------------------- 7 6 Operating Instructions------------------------------------------ 7 7 Schematic Diagram----------------------------------------------8
7.1. For Schematic Diagram----------------------------------8
7.1.1. Base Unit (Base Unit (Main)) ---------------------- 8
7.1.2. Handset (Handset (Main))-------------------------- 8
7.2. Base Unit (Main)------------------------------------------10
7.2.1. KX-TGD210 -------------------------------------------10
7.2.2. KX-TGD220 -------------------------------------------12
7.3. Base Unit (Operation) -----------------------------------14
7.4. Handset (Main)--------------------------------------------16
8 Exploded View and Replacement Parts List -----------18
8.1. Replacement Parts List ---------------------------------18
KX-TGD210N/KX-TGD212N/KX-TGD213N/KX-TGD220N/KX-TGD222N/KX-TGD223N/KX-TGD224N/KX-TGD225N/ KX-TG443SKN/KX-TG444SKN/KX-TGDA20N
4
1 Safety Precautions
1.1. For Service Technicians
R epair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and unplugged straight out.
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover plastic parts boxes with aluminu m foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
2Warning
2.1. Battery Caution
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
Attention:
A nickel metal hydride battery that is recyclable powers the product you have purchased. Please call 1-800-8-BATTERY (1-800-822-8837) for information on how to recycle this battery.
2.2. About Lead Free Solder (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead. We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn), Silver (Ag), and Copper (Cu). This model, and ot hers l ike it , manu factur ed us ing l ead fre e sold er wi ll hav e PbF sta mped o n the P CB. F or serv ice an d repai r work we suggest using the same type of solder.
Caution
• PbF solder has a melting point that is 50 F ~ 70 F (30 C ~ 40 C) higher than Pb solder. Please use a soldering iron with temperature control and adjust it to 700 F ± 20 F (370 C ± 10 C).
• Exercise care while using higher temperature soldering irons.: Do not heat the PCB for too long time in order to prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100 F (600 C).
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the opposite side (See the figure below).
Component
Component pin
Solder
Remove all of the excess solder
(Slice View)
KX-TGD210N/KX-TGD212N/KX-TGD213N/KX-TGD220N/KX-TGD222N/KX-TGD223N/KX-TGD224N/KX-TGD225N/
KX-TG443SKN/KX-TG444SKN/KX-TGDA20N
5
2.2.1. Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer's specif ic instructions for the melting poi nt s of t hei r pro duc ts and any precautions for using their product with other materials. The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3 mm, 0.6 mm and 1.0 mm.
2.3. Discarding of P. C. Board
When discarding P. C. Board, delete all personal information such as telephone directory and caller list or scrap P. C. Board.
0.3 mm X 100 g
0.6 mm X 100 g 1.0 mm X 100 g
KX-TGD210N/KX-TGD212N/KX-TGD213N/KX-TGD220N/KX-TGD222N/KX-TGD223N/KX-TGD224N/KX-TGD225N/ KX-TG443SKN/KX-TG444SKN/KX-TGDA20N
6
3 Specifications
Note:
• Design and specifications are subject to change without notice.
Note for Service:
O peration range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition.
Analog telephone connection: Telephone Line
Range extender: KX-TGA405
Power source Receiving Method
Oscillation Method Detecting Method Tolerance of OSC Frequency Modulation Method ID Code Ringer Equivalence No. (REN) Dialing Mode Redial Speed Dialer Power Consumption
Operating Conditions
Dimensions (H x W x D) Mass (Weight)
AC Adaptor (PNLV226Z, 120 V AC, 60 Hz) Super Heterodyne PLL synthesizer Quadrature Discriminator
13.824 MHz ± 83 Hz Frequency Modulation 40 bit
0.1B
Standby: Approx. 0.6 W Maximum: Approx. 3.2 W
0 ˚C - 40 ˚ C (32 ˚F – 104 ˚F) 20 % – 80 % relative air humidity (dry)
Approx. 48 mm x 143 mm x 103 mm
Approx. 140 g
Rechargeable Ni-MH battery AAA (R03) size (1.2 V) Super Heterodyne PLL synthesizer Quadrature Discriminator 10,368,000 Hz ± 83 Hz Frequency Modulation 40 bit
Tone (DTMF)/Pulse Up to 48 digits Up to 24 digits (Phonebook) 6 days at Standby, 8 hours at Talk
0 ˚C - 40 ˚ C (32 ˚F – 104 ˚F) 20 % – 80 % relative air humidity (dry)
Approx.
Base Unit
Charger
AC Adaptor (PNLV233-AZ, 120 V AC, 60 Hz)
Standby: Approx. 0.1 W, Maximum: Approx. 1.8 W
0 ˚C - 40 ˚ C (32 ˚F – 104 ˚F) 20 % – 80 % relative air humidity (dry) Approx. 45 mm x 72 mm x 72 mm
Approx. 100 g
Tone (DTMF)/Pulse Up to 48 digits Up to 24 digits (Phonebook)
for KX-TGD210:
for KX-TGD220:
Standby: Approx. 0.7 W Maximum: Approx. 3.5 W
168 mm x 48 mm x 30 mm
for KX-TGD210:
for KX-TGD220:
Approx. 170 g
Approx.
130
g
Handset
Duplex procedure:
TDMA (Time Division Multip leAccess)
Channel spacing:
1,728 MHz
Bit rate:
1,152 Mbit/s
Modulation:
GFSK (Gaussian Frequency Shift Keying)
RF transmission power:
115 mW (max.)
Voice coding:
ADPCM 32 kbit/s
Standard:
DECT 6.0 (Digital Enhanced Cordless Telecommunications 6.0)
Number of channels:
60 Duplex Channels
Frequency range:
1.92 GHz to 1.93 GHz
Loading...
+ 14 hidden pages