Panasonic KX-TG7511HGB, KX-TGA750FXB Service manual

ORDER NO. KM41006158CE
Telephone Equipment
Model No. KX-TG7511HGB
KX-TGA750FXB
Digital Cordless Phone
© Panasonic System Networks Co., Ltd. 2010 Unauthorized copying and distribution is a violation of law.
KX-TG7511HGB/KX-TGA750FXB
2
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 4
1.1. For Service Technicians --------------------------------- 4
2 Warning-------------------------------------------------------------- 4
2.1. Battery Caution--------------------------------------------- 4
2.2. About Lead Free Solder (Pbf: Pb free)--------------- 4
2.3. Discarding of P.C. Board--------------------------------- 5
3 Specifications ----------------------------------------------------- 6 4 Technical Descriptions----------------------------------------- 7
4.1. Block Diagram (Base Unit)------------------------------ 7
4.2. Circuit Operation (Base Unit)--------------------------- 8
4.3. Block Diagram (Handset)-------------------------------11
4.4. Circuit Operation (Handset)----------------------------12
4.5. Circuit Operation (Charger Unit)----------------------13
4.6. Signal Route -----------------------------------------------14
5 Location of Controls and Components ------------------16 6 Installation Instructions---------------------------------------16 7 Operating Instructions-----------------------------------------16
7.1. For Service Hint-------------------------------------------16
8 Service Mode -----------------------------------------------------17
8.1. Engineering Mode----------------------------------------17
8.2. Copying Phonebook Items when Repairing -------21
8.3. How to Clear User Setting------------------------------23
9 Troubleshooting Guide----------------------------------------24
9.1. Troubleshooting Flowchart -----------------------------24
9.2. Troubleshooting by Symptom (Base Unit and Charger Unit) ----------------------------------------------36
9.3. Troubleshooting by Symptom (Handset) -----------40
10 Disassembly and Assembly Instructions ---------------44
10.1. Disassembly Instructions-------------------------------44
10.2. How to Replace the Handset LCD -------------------47
11 Measurements and Adjustments---------------------------48
11.1. Equipment Required -------------------------------------48
11.2. The Setting Method of JIG (Base Unit) -------------48
11.3. Adjustment Standard (Base Unit)---------------------50
11.4. Adjustment Standard (Charger Unit)-----------------51
11.5. The Setting Method of JIG (Handset) ---------------52
11.6. Adjustment Standard (Handset) ----------------------54
11.7. Things to Do after Replacing IC or X'tal ------------55
11.8. RF Specification-------------------------------------------57
11.9. How to Check the Handset Speaker or Receiver ----------------------------------------------------58
11.10. Frequency Table (MHz) ---------------------------------58
12 Miscellaneous ----------------------------------------------------59
12.1. How to Replace the Flat Package IC ----------------59
12.2. How to Replace the Shield Case---------------------61
12.3. Terminal Guide of the ICs, Transistors, Diodes and Electrolytic Capacitors-----------------------------63
13 Schematic Diagram ---------------------------------------------64
13.1. For Schematic Diagram---------------------------------64
13.2. Schematic Diagram (Base Unit) ----------------------66
13.3. Schematic Diagram (Handset) ------------------------68
13.4. Schematic Diagram (Charger Unit) ------------------70
14 Printed Circuit Board-------------------------------------------71
14.1. Circuit Board (Base Unit_Main)-----------------------71
14.2. Circuit Board (Handset)---------------------------------73
14.3. Circuit Board (Charger Unit) ---------------------------75
15 Exploded View and Replacement Parts List -----------76
15.1. Cabinet and Electrical Parts (Base Unit) -----------76
KX-TG7511HGB/KX-TGA750FXB
15.2. Cabinet and Electrical Parts (Handset)------------- 77
15.3. Cabinet and Electrical Parts (Charger Unit) ------- 78
15.4. Accessories------------------------------------------------ 79
15.5. Replacement Part List ---------------------------------- 80
3
KX-TG7511HGB/KX-TGA750FXB
1 Safety Precautions
1.1. For Service Technicians
Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and unplugged straight out.
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover plastic parts boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
2Warning
2.1. Battery Caution
1. Danger of explosion if battery is incorrectly replaced.
2. Replace only with the same or equivalent type recommended by the manufacturer.
3. Dispose of used batteries according to the manufacture’s Instructions.
2.2. About Lead Free Solder (Pbf: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead. We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn), Silver (Ag), and Copper (Cu). This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair work we suggest using the same type of solder.
Caution
• PbF solder has a melting point that is 50 °F ~ 70 °F (30 °C ~ 40 °C) higher than Pb solder. Please use a soldering iron with temperature control and adjust it to 700 °F ± 20 °F (370 °C ± 10 °C).
• Exercise care while using higher temperature soldering irons.: Do not heat the PCB for too long time in order to prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100 °F (600 °C).
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the opposite side (See the figure below).
4
KX-TG7511HGB/KX-TGA750FXB
2.2.1. Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other materials. The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3 mm, 0.6 mm and 1.0 mm.
2.3. Discarding of P.C. Board
When discarding P. C. Board, delete all personal information such as telephone directory and caller list or scrap P. C. Board.
5
KX-TG7511HGB/KX-TGA750FXB
3 Specifications
Note:
• Design and specifications are subject to change without notice.
Note for Service:
Operation range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition.
Analog telephone connection: Telephone Line
Optional headset: KX-TCA94EX
6
4 Technical Descriptions
D3
X1
4.1. Block Diagram (Base Unit)
KX-TG7511HGB/KX-TGA750FXB
T1 AN
T1 AN
on
X R
5
Burst Encoding
Speech Encoding
T2
ANT1
AN
6
801 D
V R D A
-P
p
n
X
DD
X
R
V
R
3
2
RF
Burst Decoding
Speech Decoding
T2 AN
72
9
A P
F R
4
p
X T
77
75
PLL
MOD/DEMOD
DSP
ADPCM
Codec Filter
IC801
6
3
n
on
X
P
T
787374
BMC
ANT2
8
7
L E S P
68
z H M
10.3
L
1
A T
X
on
X T
X
9
80
10
KX-TG7511 BLOCK DIAGRAM (BASE UNIT)
Pump
Charge
43
IC7
BBIC
A/D
D/A
Analog
25
18
16
Audio
Off-Hook Line Voltage
Q3,Q4,Q5
Hook Switch
Bridge
Rect D3
2 L
L1
o TEL_LINE
End
Front
23
HOOK
20
211924
Interface
Bell/Caller ID
CPU
57
BELL
SCL
44
58
SDA
IC401
EEPROM
Charge
Detector
2.5V
CHARGE
CONTACT
Limit
Resistor
P C D
To AC Adaptor
3.0 V
IC2
M C D
Q9
2.4 V
2.4V
IC3
Reg.
1.8 V
1.8V
Reg.
Q8
7
KX-TG7511HGB/KX-TGA750FXB
4.2. Circuit Operation (Base Unit)
4.2.1. Outline
Base Unit consists of the following ICs as shown in Block Diagram (Base Unit) (P.7).
• DECT BBIC (Base Band IC): IC7
- Handling all the audio, signal and data processing needed in a DECT base unit
- Controlling the DECT specific physical layer and radio section (Burst Module Controller section)
- ADPCM code filter for speech encoding and speech decoding (DSP section)
- Echo-cancellation and Echo-suppression (DSP section)
- Any tones (tone, sidetone, ringing tone, etc.) generation (DSP section)
- DTMF receiver (DSP section)
- Clock Generation for RF Module
- ADC, DAC, timer, and power control circuitry
- PLL Oscillator
-Detector
- Compress/Expander
- First Mixer
- All interfaces (ex: RF Power Amp, EEPROM, LED, Analog Front End, etc.)
• RF Power Amp.: IC801
- Amplifier for transmission and reception
• EEPROM: IC401
- Temporary operating parameters (for RF, etc.)
• Additionally,
- Power Supply Circuit (+3.0 V, +2.4 V, +1.8 V output)
- Crystal Circuit (10.368 MHz)
- Charge Circuit
- Telephone Line Interface Circuit
8
KX-TG7511HGB/KX-TGA750FXB
4.2.2. Power Supply Circuit
The power is supplied to the DECT BBIC, RF Module, EEPROM and Charge Contact from AC Adaptor (+6.5 V) as shown in Fig.101. The power supply is as follows;
• DECT BBIC (IC7): DC Jack (+6.5 V) IC2 IC7 DC Jack (+6.5 V) IC2 Q9 IC7 DC Jack (+6.5 V) IC2 Q8 IC7
• RF Power Amp. (IC801): DC Jack (+6.5 V) IC2 IC801 (Power AMP)
• EEPROM (IC401): DC Jack (+6.5 V) IC2 IC7 IC401
• Charge Contact (TP16): DC Jack (+6.5 V) R56 R55 D22 TP16
<Fig.101>
9
KX-TG7511HGB/KX-TGA750FXB
4.2.3. Telephone Line Interface
<Function>
• Bell signal detection
• Clip signal detection
• ON/OFF hook circuit
Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection:
In the standby mode, Q3 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the L1T (A) and L1R (B) leads (when the telephone rings), the AC ring voltage is transferred as follows;
•B → L2 → C4 → R6 → R33 → IC7 Pin 21 (CID INp)
•A → L1 → C3 → R4 → R35 → IC7 Pin 20 (CID INn)
ON/OFF hook circuit:
In the standby mode, Q3 is open, and connected as to cut the DC loop current and to cut the voice signal. The unit is consequently in an on-hook condition. When IC7 detects a ring signal or press the TALK Key onto the handset, Q4 turns on and then Q3 turns on, thus providing an off-hook condition (DC current flows through the circuit) and the following signal flow makes the loop current.
•B → L2 →D3 → Q3 → Q5 → R21 → R22 → D3 → L1 →A [OFF HOOK]
4.2.4. Transmitter/Receiver
• Audio Circuits and DTMF tone signal circuits. Base Unit and Handset mainly consist of RF Module and DECT BBIC. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency.
Signal Path:
*Refer to Signal Route (P.14).
4.2.4.1. Transmitter Block
The voice signal input from the TEL LINE interface goes to RF Power Amp. (IC801) through DECT BBIC (IC7) as shown in Block Diagram (Base Unit) (P.7) The voice signal passes through the analog part of IC7 where it is amplified and converted to a digital audio stream signal. The burst switch controller processes this stream performing encryption and scrambling, adding the various other fields to produce the GAP (Generic Access Profile) standard DECT frame, assigning to a time slot and channel etc. In IC7, the carrier frequency is changing, and frequency modulated RF signal is generated.In IC801,RF signal is amplified, and radiated from antenna. Handset detects the voice signal or data signal in the circuit same as the following explanation of
Receiver Block.
4.2.4.2. Receiver Block
The signal of 1900 MHz band (1881.792 MHz ~ 1897.344 MHz) which is input from antenna is input to IC7 as shown in Block Diagram (Base Unit) (P.7).
In IC7, the signal of 1900 MHz band is downconverted to 864 kHz signal and demodulated, as GAP (Generic Access Profile) standard DECT frames. It passes through the decoding section burst switch controller where it separates out the frame information and performs de-encryption and de-scrambling as required. It then goes to the DSP section where it is turned back
into analog audio. This is amplified by the analog front end, and goes to the TEL LINE Interface.
4.2.5. Pulse Dialling
During pulse dialling the hookswitch (Q3, Q4) is used to generate the pulses using the HOOK control signal, which is set high during pulses. To force the line impedance low during the “pause” intervals between dial pulses, the PULSE_DIAL signal turns on Q2.
10
4.3. Block Diagram (Handset)
Q4, Q9, R7
ANT1
ANT1
KX-TG7511HGB/KX-TGA750FXB
RXon
5
RXn
3
Burst
Decoding
Speech
Decoding
DA801
VDD-PADRY
RXp
TXp
2
75
Burst
Encoding
ADPCM
Speech
Encoding
9
RF PA
4
TXn
77
RF
PLL
MOD/DEMOD
Filter
Codec
IC801
367
Pon
78
737480
BMC
DSP
8
PSEL
TXon
X1
XTAL
9
10.368
MHz
10
BATTERY
ON SWITCH
44
KEYPAD
ROWS
COLUMNS
48, 49, 50, 51
22, 23, 24, 25, 26
Pump
Charge
IC1
BBIC
43 42
CP2.5V CP4.0V
KX-TGA750 BLOCK DIAGRAM (HANDSET)
33
35
SPEAKER
D/A
A/D
19
15
16
RECEIVER
MIC
Analog
20
End
Front
32
31
CHARGE
CHARGE_CTRL
CHARGE
CIRCUIT
Q4, Q9, R7
CHARGE(+)
CHARGE
CONTACTS
57
58
SCL
SDA
IC3
EEPROM
D7
CHARGE(-)
BATT+
CPU
36
VBAT
BATTERY
TERMINAL
13
1.8 V
R45
BATT-
LDO_CTRL
66
56
Q2
1.8 V
CD
RESET
635455
CSB
SDA
SCL
LCD
52
68
KEY LED
BELL LED
CP4.0V
WHITE LED
on LCD unit
11
KX-TG7511HGB/KX-TGA750FXB
4.4. Circuit Operation (Handset)
4.4.1. Outline
Handset consists of the following ICs as shown in Block Diagram (Handset) (P.11).
• DECT BBIC (Base Band IC): IC1
- All data signals (forming/analyzing ACK or CMD signal)
- All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD, RF Power Amp.)
- PLL Oscillator
-Detector
- Compress/Expander
- Reception
• RF Power Amp: IC801
- Amplifier for transmission
• EEPROM: IC3
- Temporary operating parameters (for RF, etc.)
4.4.2. Power Supply Circuit/Reset Circuit
Circuit Operation:
When power on the Handset, the voltage is as follows; BATTERY(2.2 V ~ 2.6 V: BATT+) F1 Q2 (1.8 V), IC1-43pin (2.5V) The Reset signal generates IC1 (61 pin) and 1.8 V.
4.4.3. Charge Circuit
Circuit Operation:
When charging the handset on the Base Unit, the charge current is as follows; DC+(6.5 V) R56 R55 D22 CHARGE+(Base) CHARGE+(Handset) Q4 D7 F1 BATTERY+... Battery... BATTERY- → R45 → GND → CHARGE-(Handset)→ CHARGE-(Base) → GND → DC-(GND) In this way, the BBIC on Handset detects the fact that the battery is charged. The charge current is controlled by switching Q9 of Handset.
Refer to Fig.101 in Power Supply Circuit (P.9).
4.4.4. Battery Low/Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery. The detected voltage is as follows;
• Battery Low
Battery voltage: V(Batt) 2.25 V ± 50 mV
The BBIC detects this level and " " starts flashing.
• Power Down
Battery voltage: V(Batt) 2.0 V ± 50 mV
The BBIC detects this level and power down.
4.4.5. Speakerphone
The hands-free loudspeaker at SP+ and SP- is used to generate the ring alarm.
12
4.5. Circuit Operation (Charger Unit)
4.5.1. Power Supply Circuit
The power supply is as shown.
KX-TG7511HGB/KX-TGA750FXB
13
KX-TG7511HGB/KX-TGA750FXB
4.6. Signal Route
14
KX-TG7511HGB/KX-TGA750FXB
15
KX-TG7511HGB/KX-TGA750FXB
5 Location of Controls and Components
Refer to the Operating Instructions.
Note:
You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
6 Installation Instructions
Refer to the Operating Instructions.
Note:
You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
7 Operating Instructions
Refer to the Operating Instructions.
Note:
You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
7.1. For Service Hint
16
8 Service Mode
8.1. Engineering Mode
8.1.1. Base Unit
KX-TG7511HGB/KX-TGA750FXB
17
KX-TG7511HGB/KX-TGA750FXB
Frequently Used Items (Base Unit)
ex.)
Items Address Default Data New Data Remarks
C-ID (FSK) sensitivity 05 4B 00 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01” or “02”,
C-ID (DTMF) sensitivity 05 80 50 60 (6 dB up) 70 (12 dB up) When hex changes from “50” to “60” or “70”,
SMS (FSK) receiving sensitivity SMS (FSK) sending level 04 9B/04 9A 00/04 19/20 (6 dB
Frequency 00 08/00 07 02/70 - - Use these items in a READ-ONLY mode to ID 00 02~00 06 Given value - -
Bell length 02 1D 32 (5sec) (*3) 1E (3 sec) 14 (2 sec) This is time until bell stops ringing.
PULSE Dial speed (10PPS -> 20PPS)
04 D6 00 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01”or “02”,
32/40 (12 dB
up)
01 F8 21 (33msec)
(*3)
01 F9 43 (67msec)
(*3)
02 0C 47 (870msec)
(*3)
up)
18 (20msec) - This is pulse make time. (Unit:1 ms)
1A (30msec) - This is pulse break time. (Unit:1 ms)
2C (440msec) - This is inter-digit time in pulse mode.
gain increases by 6 dB or 12 dB.
gain increases by 6 dB or 12 dB.
gain increases by 6 dB or 12 dB. When hex changes from “00 0B” to “00 16”or “00 2C”, gain increases by 6 dB or 12 dB.
confirm the contents. Careless rewriting may cause serious damage to the computer system.
(Unit: 100 ms)
(Unit:10 ms)
Note:
(*1) Refer to Registering a Handset to a Base Unit in the Operating Instructions. (*2) When you enter the address or New Data, please refer to the table below.
Desired Number (hex) Input Keys Desired Number (hex) Input Keys
00 A[R] + 0 11 B[R] + 1
.. C[R] + 2 .. D[R] + 3 .. E[R] + 4
99 F[R] + 5
(*3)
Bell length 32(hex) = 50(dec) 50 × 100 msec = 5000 msec (5 sec) PULSE Dial speed (10PPS -> 20PPS)
21(hex) = 33(dec) 33 × 1msec = 33msec 43(hex) = 67(dec) 67 × 1msec = 67msec 47(hex) = 71(dec) 71 × 10msec = 710msec
18
8.1.2. Handset
KX-TG7511HGB/KX-TGA750FXB
19
KX-TG7511HGB/KX-TGA750FXB
Frequently Used Items (Handset)
ex.)
Items Address Default Data New Data Possible Adjusted
Value MAX (hex)
Sending level 03 17 Adjusted value Given value FF D0 (*2)
Receiving level 03 18 Adjusted value Given value FF D0 (*3)
Battery Low 00 09 70 - - -
Frequency 00 08/00 07 02/70 - - -
ID 00 02~00 06 Given value - - -
Possible Adjusted
Value MIN (hex)
Note:
(*1) When you enter the address or New Data, please refer to the table below.
Desired Number (hex.) Input Keys Desired Number (hex.) Input Keys
00 A[R] + 0 11 B[R] + 1
.. C[R] + 2 .. D[R] + 3 .. E[R] + 4
99 F[R] + 5
(*2) When adding “01” (hex) to default value, sending level increases by 0.25 dB. ex.)
Item Default Data New Data
E7 EB E3
Sending level -2dBm -1dBm -3dBm
(*3) When reducing “01” (hex) from default value, receiving level increases by 0.25 dB. ex.)
Remarks
(*4)
Item Default Data New Data
E7 EB E3
Receiving level -22dBm -21dBm -23dBm
(*4) Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may cause serious damage to the
handset.
20
KX-TG7511HGB/KX-TGA750FXB
8.2. Copying Phonebook Items when Repairing
You can copy the handset phonebook to another (compatible Panasonic) handset. This will help to save the original phonebook data which the customer has registered. Available models: KX-TG7511 Refer to the following procedures.
Note:
• BS=Base Unit, HS=Handset
• If the max number of handsets are already registered to the base unit, a new handset cannot be registered.
• To register the handset, refer to Registering a Handset to a Base Unit in the Operating Instructions.
• To cancel the handset, refer to Deregistering a Handset in the Operating Instructions.
• To copy the handset phonebook, refer to Copying Phonebook Entries in the Operating Instructions.
21
KX-TG7511HGB/KX-TGA750FXB
Note:
• BS=Base Unit, HS=Handset
• If the max number of handsets are already registered to the base unit, a new handset cannot be registered.
• To register the handset, refer to Registering a Handset to a Base Unit in the Operating Instructions.
• To cancel the handset, refer to Deregistering a Handset in the Operating Instructions.
• To copy the handset phonebook, refer to Copying Phonebook Entries in the Operating Instructions.
22
KX-TG7511HGB/KX-TGA750FXB
8.3. How to Clear User Setting
Units are reset to the Factory settings by this operation (Erase stored Phone numbers, Caller list and etc.)
Note:
• Some menus are not reset. Refer to Operating Instructions (P.16).
• The reset menus differ depending on the following operations.
This operation should not be performed for a usual repair.
8.3.1. Resetting both base unit and handset
Both the base unit and the registered handset which you did the following steps to are reset. Other registered handsets will not be reset.
Note:
(*1) Refer to Registering a Handset to a Base Unit in the Operating Instructions.
8.3.2. Resetting only handset
The only handset is reset by doing the following steps to .
Note: (*2)
• The handset registration to the base unit is cancelled.
• If the handset needs to be registered to the base unit, refer to Registering a Handset to a Base Unit in the Operating Instructions.
• If users do not bring the base unit with them, the registration procedure has to be done by users themselves.
23
KX-TG7511HGB/KX-TGA750FXB
9 Troubleshooting Guide
9.1. Troubleshooting Flowchart
Flow Chart
Cross Reference:
Check Power (P.25) Bell Reception (P.35) Check Battery Charge (P.26) Check Link (P.27) Check the RF part (P.31) Check Handset Transmission (P.34) Check Handset Reception (P.34) Signal Route (P.14) Check Caller ID (P.34)
24
9.1.1. Check Power
9.1.1.1. Base Unit
Is the AC Adaptor inserted into AC outlet? (*1)
KX-TG7511HGB/KX-TGA750FXB
Cross Reference:
Power Supply Circuit (P.9)
9.1.1.2. Handset
Note:
(*1) Refer to Specifications (P.6) for part number and supply voltage of AC Adaptor.
Cross Reference:
Power Supply Circuit/Reset Circuit (P.12)
25
KX-TG7511HGB/KX-TGA750FXB
9.1.2. Check Battery Charge
9.1.2.1. Base Unit
Cross Reference:
Charge Circuit (P.12)
9.1.2.2. Handset
Cross Reference:
Check Power (P.25)
Charge Circuit (P.12)
9.1.2.3. Charger Unit
Cross Reference:
Charge Circuit (P.12)
26
Loading...
+ 58 hidden pages