NORSK
Les bruksanvisningen nøye før du bruker
denne enheten, og oppbevar den for
fremtidig bruk.
14 ~ 19
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
Air inlet
Air
outlet
DEFINITION
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action
that is PROHIBITED.
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
These symbols denote actions
that are COMPULSORY.
This sign warns of
Caution
injury or damage
to property.
Remote Control
• Do not use rechargeable
(Ni-Cd) batteries.
• Do not allow infants and
small children to play
with the remote control
to prevent them from
accidentally swallowing the
batteries.
• Remove the batteries if the
unit is not going to be used for
a long period of time.
• New batteries of the same
type must be inserted
following the polarity stated
to prevent malfunction of the
remote control.
Indoor Unit
• Do not install, remove and
reinstall the unit by yourself;
improper installation will
cause leakage, electric
shock or fi re. Please consult
authorized dealer or specialist
for the installation work.
• Do not insert your fi ngers or
other objects into the unit,
rotating parts may cause
injury.
• Do not attempt to repair the
unit by yourself.
Air inlet
Air
outlet
Indoor Unit
• Do not install the unit in a potentially
explosive atmosphere.
• Do not wash the unit with water,
benzene, thinner or scouring
powder.
• Do not use for other purposes such
as preservation of food.
• Do not use any combustible
equipment in front of the airfl ow
outlet.
• Do not expose directly to cold air for
a long period.
• Ensure that the drainage pipe is
connected properly. Otherwise,
leakage may occur.
• Aerate the room regularly.
Power Supply
Power Supply
• Do not share the same power outlet with
other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualifi ed persons in order
to avoid a hazard.
• This equipment must be earthed and
strongly recommended to be installed with
Air inlet
Air inlet
Air outlet
• Switch off the power supply before
cleaning or servicing.
• Turn off the power supply if the unit is
not used for a long period of time.
• This air conditioner is equipped with
a built-in surge protective device.
However, in order to further protect
your air conditioner from being
damaged by abnormally strong
lightning activity, you may want to
disconnect it from the power supply.
Do not touch the air conditioner
during lightning, it may cause electric
shock.
Earth Leakage Circuit Breaker (ELCB) or
Residual Current Device (RCD). Otherwise,
it may cause electrical shock or fi re in case
of malfunction.
• In case of emergency or abnormal
conditions (burnt smell, etc), turn off the
power supply, and please consult authorized
Outdoor Unit
• Do not sit or step on the unit, you
may fall down accidentally.
dealer.
• Do not touch the sharp aluminium
fi n, sharp parts may cause injury.
Outdoor Unit
• Do not insert your fi ngers or other objects
into the unit, rotating parts may cause injury.
• After long periods of use, make sure
the installation rack is not damaged.
2
REGULATORY INFORMATION REGULATORY INFORMATION
OPERATION CONDITION
TABLE OF CONTENTS
NOTE :
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
COOLING
HEATING
+8/10°C
HEAT
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
Maximum32234326
Minimum16111611
Maximum30-2418
Minimum16--15-
Maximum10---
Minimum8--15-
IndoorOutdoor
*DBT*WBT*DBT*WBT
Thank you for purchasing
Panasonic Air Conditioner
TABLE OF CONTENTS
SAFETY PRECAUTIONS
REGULATORY INFORMATION
PRODUCT OVERVIEW &
OPERATIONS
CARE & CLEANING
TROUBLESHOOTING
QUICK GUIDE
NOTE :
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
BACK COVER
4~5
2
ENGLISH
3
6
7
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic
products and batteries should not be mixed with general household waste.
For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection
points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential
negative effects on human health and the environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products and batteries, please contact your local municipality, your
waste disposal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or
dealer and ask for the correct method of disposal.
Pb
• Do not switch ON the unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the
Directive for the chemical involved.
• Please be aware of the OFF indication on the remote control display
to prevent the unit from starting / stopping improperly.
Auto OFF/ON button
• Used when remote control is misplaced or
malfunction.
ActionMode
Press once.Auto
Press and hold until 1 beep is
heard, then release.
Press and hold until 1 beep is
heard, then release.
Press again until 2 beeps, then
release.
Press the button to turn off.
INDICATOR
(GREEN)
(ORANGE)
(GREEN)
(ORANGE)
(ORANGE)
TO TURN ON OR OFF THE UNIT
Cooling
Heating
4
Remote control
display
TO SET TEMPERATURE
• Selection range: 16˚C ~ 30˚C (Not applicable for FAN mode).
• Operating the unit within the recommended temperature could
induce energy saving.
HEAT mode : 20˚C ~ 24˚C.
COOL mode : 26˚C ~ 28˚C.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• During operation mode selection the power indicator blinks.
• Unit selects operation mode every 30 minutes according to
temperature setting, outdoor and room temperature.
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. The power indicator blinks during this
operation.
COOL mode - To enjoy cool air
FAN mode - To circulate air in the room
MOVABLE PANEL
• Opens for air intake when operation starts, and closes when
operation stops. During this time, do not hold it as it may cause
malfunction or breakdown.
TO SET THE TIMER
TO SELECT FAN SPEED
OPTIONAL SETTINGS
()
(5 OPTIONS)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
ENGLISH
TO ADJUST
AIR SWING
AIRFLOW DIRECTION
(5 OPTIONS)
• Keeps the room ventilated.
• If AUTO is set, the louvers swing left/right and
up/down automatically.
• In heat mode, the air blows horizontally for a while,
then starts to blow downwards and the airfl ow louvers
start to swing left/right after the temperature rises.
+8/10˚C
HEAT
TO USE
MAINTENANCE
HEATING
• Maintain indoor temperature at 8/10°C.
Fan switches to high fan speed
automatically.
• This operation overwrite the operation
mode and could be cancelled by pressing
.
• Defrost operation at outdoor unit will
result in sudden cold air from indoor unit.
Eliminate cold air with heat mode.
TO ENJOY QUIET
ENVIRONMENT
• This operation reduces airfl ow noise.
TO ACHIEVE
TEMPERATURE
QUICKLY
• and can be activated in all modes
and can be cancelled by pressing the respective
button again.
•
, and
+8/10˚C
HEAT
operations can not be
activated at the same time.
+8/10˚C
HEAT
•
operation can be activated independently.
10˚C
8˚C
Select ON or
Set the time.Confi rm.
OFF timer.
• To cancel ON or OFF timer, press
or then
press .
• When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
OPTIONAL SETTINGS
.
Press and hold for 5 seconds to dim or
restore the unit’s indicator brightness.
Press and hold for approximately 10 seconds
to show temperature setting in °C or °F.
Press and hold for approximately 5 seconds
to show 12-hour (am/pm) or 24-hour time
indication.
Press to restore the remote control’s default
setting.
,
Not used in normal operations.
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
5
CARE & CLEANING CARE & CLEANING
Remove
WASHING INSTRUCTIONS
INDOOR UNIT
HINT
SUPER ALLERU-BUSTER FILTER
TOP GRILL
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
NON SERVICEABLE CRITERIAS
FOR EXTENDED NON-USE
AIR FILTERS
Remove
ALUMINIUM FIN
FRONT PANEL & MOVABLE PANEL
MOVABLE PANEL
FRONT PANEL
• Switch off the power supply before cleaning.
CAUTION
WASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
TOP GRILL
• Push up and pull to remove. Wash
gently and dry.
• Do not dry under direct sunlight.
•Do not touch the aluminium fi n, sharp part may cause injury.
Remove
HINT
• To ensure optimal performance of the unit, cleaning
maintenance have to be carried out at regular intervals.
Dirty unit may caused malfunction and you may retrieve
error code “H99”. Please consult authorized dealer.
FRONT PANEL & MOVABLE PANEL
MOVABLE PANEL
FRONT PANEL
• Do not remove the movable panel from
front panel.
• Raise and pull to remove. Wash gently
and dry.
• Do not dry under direct sunlight.
ALUMINIUM FIN
INDOOR UNIT
Wipe the unit gently with a soft, dry cloth.
Remove
AIR FILTERS
• Air fi lters cleaning is needed every two weeks.
• Wash/rinse the fi lters gently with water to avoid damage to
the fi lter surface.
• Dry the fi lters thoroughly under the shade, away from fi re
or direct sunlight.
• Replace any damage fi lter.
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select Cooling/Heating
operation, after 15 minutes of operation, it is normal to
have the following temperature difference between air inlet
and air outlet vents:
Cooling: ≥ 8°C Heating: ≥ 14°C
FOR EXTENDED NON-USE
• Activate Heat mode for 2~3 hours to remove moisture left in
the internal parts thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries.
6
SUPER ALLERU-BUSTER FILTER
Vacuum the super
alleru-buster fi lter.
• It is recommended to clean the fi lter every 6
months.
• Replace the fi lter every 3 years or replace
any damaged fi lter.
Part no.: CZ-SA14P
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult
authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
TROUBLESHOOTING TROUBLESHOOTING
Symptom
Check
Symptom
Cause
The following symptoms do not indicate malfunction.
Check the following before calling for servicing.
The unit stops and the timer indicator blinks.
The following symptoms do not indicate malfunction.
Symptom
Mist emerges from indoor unit.• Condensation effect due to cooling process.
Water fl owing sound during operation.• Refrigerant fl ow inside the unit.
The room has a peculiar odour.• This may due to damp smell emitted by the wall, carpet, furniture or
Indoor fan stops occasionally during automatic
fan speed setting.
Operation is delayed a few minutes after
restart.
Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes.
Timer indicator is always on.• The timer setting repeats daily once set.
Power indicator blinks during operation and
the indoor fan is stopped.
Indoor fan stops occasionally during heating
operation.
Power indicator blinks before the unit is
switched on.
Cracking sound during operation.• Changes of temperature cause the expansion/contraction of the unit.
Check the following before calling for servicing.
Symptom
Heating/Cooling operation is not working
effi ciently.
Noisy during operation.• Check if the unit has been installed at an incline.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.• Check if the circuit breaker is tripped.
The unit does not receive the signal from the
remote control.
Cause
clothing.
• This helps to remove the surrounding odours.
• The delay is a protection to the unit’s compressor.
• The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
• To avoid unintended cooling effect.
• This is a preliminary step in preparation for the operation when the ON
timer has been set.
Check
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if timers have been set.
• Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter. Please
consult authorized dealer.
ENGLISH
The unit stops and the timer indicator blinks.
Use remote control to retrieve error code.
Press until you hear
Press for 5
1
seconds.
Press for 5
3
seconds to
quit checking.
4
Turn the unit off and reveal the error code to authorized dealer.
2
beep sound, then jot
down the error code.
Note:
• For certain error, you may
restart the unit with limited
operation with 4 beeps during
operation starts.
7
SÄKERHETSFÖRESKRIIFTER SÄKERHETSFÖRESKRIIFTER
Luftintag
Utblåsning
Utblåsning
DEFINITIONER
Instruktioner klassifi ceras med följande symboler:
Denna symbol betecknar en
handling som är FÖRBJUDEN.
För att förhindra skada på person eller egendom måste följande instruktioner följas.
Felaktig användning orsakad av att skötselanvisningen inte följts kan leda till skador, nedan klassas deras allvar:
Varning
Fjärrkontroll
• Använd inte
uppladdningsbara batterier
(Ni-Cd) till fjärrkontrollen.
• Låt inte små barn leka med
fjärrkontrollen för att förhindra
att de av olyckshändelse
råkar svälja batterierna.
• Ta ur batterierna ur
fjärrkontrollen om
värmepumpen inte skall
användas under en längre tid.
• Nya batterier av samma
typ måste sättas i med rätt
polaritet för att förhindra dålig
funktion för fjärrkontrollen.
Denna symbol varnar för dödsfara eller allvarliga
skador.
Inomhusdel
• Du får inte på egen hand
installera, demontera eller
återinstallera värmepumpen;
felaktig installation kan
orsaka läckage, elstöt eller
brand. Anlita auktoriserad
återförsäljare eller specialist
för installationsarbetet.
• För inte in dina fi ngrar eller
andra föremål i enheten,
eftersom roterande delar kan
orsaka personskada.
• Reparera inte värmepumpen
själv.
Luftintag
Dessa symboler betecknar
handlingar som MÅSTE
FÖLJAS.
Försiktighet
• Installera inte värmepumpen i
explosiv miljö.
• Tvätta inte värmepumpen med
vatten, bensol, thinner eller
skurpulver.
• Använd inte värmepumpen för
annat ändamål än den är avsedd
för.
• Använd inte brännbar utrustning
framför luftströmmen.
• Sitt inte direkt i luftriktningen under
längre tidsperioder vid kyldrift.
• Se till att dräneringsslangen är
korrekt ansluten. Annars kan
läckage uppstå.
• Vädra rummet regelbundet.
Denna symbol
varnar för
personskada
eller skada på
egendom.
Inomhusdel
Strömförsörjning
• Dela inte samma vägguttag med annan
utrustning.
• Ändra inte på elkablar.
• Använd inte skarvkablar.
• Ta inte i värmepumpen med våta händer.
• Använd godkänd elkabel.
• Om elkabeln är skadad måste den bytas av
tillverkaren eller auktoriserad serviceverkstad
eller motsvarande behörig person för att
undvika skador.
• Denna utrustning måste vara jordad och
du rekommenderas starkt att installera den
Utblåsning
Luftintag
Luftintag
Utblåsning
Strömförsörjning
• Slå ifrån strömmen innan rengöring
eller service.
• Slå ifrån strömmen om enheten inte
ska användas under en längre tid.
• Denna luftkonditionering har ett
inbyggt överspänningsskydd. Om
du emellertid vill vidta ytterligare
försiktighetsåtgärder för att skydda
luftkonditioneringen från att skadas
vid kraftiga åskoväder, bör du
överväga att koppla bort enheten
från strömförsörjningen. Vidrör inte
luftkonditioneringen under åskoväder,
du kan få en elstöt.
med Jordfelsbrytare (ELCB, Earth Leakage
Circuit Breaker) eller Skyddsenhet för
Restström (RCD, Residual Current Device).
Annars kan den orsaka elstöt eller eldsvåda,
ifall fel uppstår på den.
• Vid nödfall eller onormala förhållanden
(lukten av bränt, etc), stäng av strömmen,
och vänd dig till en auktoriserad
återförsäljare för att få hjälp.
Utomhusdelen
• Sitt inte och ställ dig inte på enheten,
eftersom du då kan trilla och skada
dig.
• Rör inte den vassa
aluminiumfl änsen, eftersom vassa
Utomhusdelen
• För inte in dina fi ngrar eller andra föremål
i enheten, eftersom roterande delar kan
8
orsaka personskada.
delar kan orsaka personskada.
• Efter lång tids användning, se till att
monteringskonsolen inte är skadad.
TILLÅTNA DRIFTSFÖRHÅLLANDEN
LEGALA FÖRESKRIFTER LEGALA FÖRESKRIFTER
INNEHÅLLSFÖRTECKNING
OBS :
Denna apparat är inte avsedd att användas av personer (inklusive barn) med
reducerad fysiska, sensoriska eller mentala färdigheter, eller brist på erfarenhet och
kunskap, ifall de inte övervakats eller instruerats om användandet av apparaten av
en person som ansvarar för deras säkerhet. Barn bör övervakas för att se till att de
inte leker med apparaten.
TILLÅTNA DRIFTSFÖRHÅLLANDEN
Värmepumpen får användas vid följande temperaturer
Temperatur (°C)
KYLA
VÄRME
+8/10°C
HEAT
* DBT: Torr temperatur
* WBT: Våt temperatur
Max.32234326
Min.16111611
Max.30-2418
Min.16--15-
Max.10---
Min.8--15-
InomhusUtomhus
*DBT*WBT*DBT*WBT
Tack för att du har köpt
Panasonic Värmepump
INNEHÅLLSFÖRTECKNING
SÄKERHETSFÖRESKRIFTER
LEGALA FÖRESKRIFTER
PRODUKTÖVERSIKT &
FUNKTIONER
UNDERHÅLL & RENGÖRING
PROBLEMLÖSNING
SNABBGUIDE
OBS :
Bilderna i denna skötselanvisning
är endast illustrativa och kan
därför skilja sig från den faktiska
modellen. Förändringar kan göras
utan föregående meddelande
angående framtida förbättringar.
BAKSIDAN
8
9
10~11
12
13
SVENSKA
Information för användare om hopsamling och avfallshantering av gammalt material och använda batterier
Dessa symboler på produkter, förpackningar och/eller medföljande dokument betyder att man inte ska blanda elektriska och
elektroniska produkter eller batterier med vanliga hushållssopor.
För att gamla produkter och använda batterier ska hanteras och återvinnas på rätt sätt ska man ta dem till passande
uppsamlingsställe i enlighet med nationella bestämmelser och direktiven 2002/96/EC och 2006/66/EC.
När du kasserar dessa produkter och batterier på rätt sätt hjälper du till att spara på värdefulla resurser och förebygga en potentiell
negativ inverkan på människors hälsa och på miljön som annars skulle kunna uppstå p.g.a. otillbörlig avfallshantering.
För mer information om uppsamling och återvinning av gamla produkter och batterier, var god kontakta din kommun, din
avfallshanterare eller det försäljningsställe där du köpte din artikel.
Olämplig avfallshantering kan beläggas med straff i enlighet med nationella bestämmelser.
För affärsanvändare inom den Europeiska Unionen
Om du vill kassera elektrisk eller elektronisk utrustning, var god kontakta din återförsäljare eller leverantör för ytterligare information.
[Information om avfallshantering i länder utanför den Europeiska unionen]
Dessa symboler är endast giltiga inom den Europeiska Unionen. Om du vill kassera dessa föremål, var god kontakta dina lokala
myndigheter eller din lokala återförsäljare och fråga efter rätt metod för avfallshantering.
Pb
• Sätt inte PÅ enheten då du vaxar golvet. Efter vaxning, vädra rummet ordentligt innan du använder enheten.
• Installera inte enheten på oljiga eller rökiga platser.
Notering till batterisymbolen (nedtill, två symbolexempel):
Denna symbol kan användas i kombination med en kemisk symbol. I detta fall iakttar den de krav som ställs upp i direktivet för den
aktuella kemikalien.
• Används då fjärrkontrollen tappats bort
eller fungerar felaktigt.
ÅtgärdFunktionssätt
Tryck på knappen en gång. Automatdrift
Tryck tills du hör ett bip-ljud.Kylning
Tryck tills du hör ett bip-ljud.
Tryck en gång till tills 2
pipljud hörs, och släpp
Värme
sedan.
Tryck ner knappen för att stänga av.
LYSDIODER
(GRÖN)
(ORANGE)
Mottagare
(GRÖN)
(ORANGE)
(ORANGE)
SÄTTA PÅ OCH STÄNGA AV ENHETEN
• Var god håll koll på indikationen OFF på fjärrkontrollens display för
att förhindra att enheten startas/stoppas på fel sätt.
STÄLLA IN TEMPERATUR
• Valområde: 16°C ~ 30°C (Ej tillgängligt i läget FAN).
• Användning av enheten inom det rekommenderade
temperaturområdet kan göra att energi sparas.
LÄGET VARMT : 20°C ~ 24°C.
LÄGET KALLT : 26°C ~ 28°C.
VÄLJA FUNKTIONSLÄGE
AUTOMATISKT LÄGE - För enklare användning
• Då val av användarläge sker blinkar driftslampan.
• Enheten väljer på nytt funktionsläge efter 30 minuter hela tiden enligt
temperaturinställning, utomhus- och rumstemperatur.
LÄGET VARMT - För att få varm luft
• Det tar en stund för enheten att värmas upp. Driftsindikatorn blinkar
under tiden.
LÄGET KALLT - För att få kall luft
Läget FAN - För att få luften att cirkulera i rummet
RÖRLIG PANEL
• Öppnas för insläpp av luft vid driftstart och stängs när airconditionern
stängs av. Under denna tid får du inte hålla i den, då detta kan
orsaka funktionsfel eller driftstopp.
10
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.